Honeywell Vista Series Wiring - Alarm System Store

  Рет қаралды 125,957

Alarm System Store

Alarm System Store

Күн бұрын

Jon Boroughs of AlarmSystemStore.Com shows you the basic wiring on a Honeywell Vista alarm system. He takes you through the wiring of the transformer, keypad, one door contact, motion sensor and a 2 and 4 wire smoke detector. If you have any tech questions then please call 888-811-0727 and choose option 2 on our phone menu.
You can visit our website here - www.alarmsystem...
You can find the aforementioned video on resistors that Jason made here - www.alarmsyste...

Пікірлер: 94
@johnsullivan8239
@johnsullivan8239 7 жыл бұрын
In the future, make sure to mention that the two-wire smoke circuit (zone 1) is polarity sensitive.
@AlarmSystemStore
@AlarmSystemStore 7 жыл бұрын
Thanks for the feedback! We might do another video on hooking 2-wire and 4-wire smokes to this system specifically seeing as we've learned a few tricks since making this video. Thanks for watching and for leaving us your thoughts!
@nimeshshah253
@nimeshshah253 Жыл бұрын
Dear John, Great effort and nice video presentation. I like to convert this unit to eWelink platform by installing smart switch. But how can we sure from outside system is armed or disarmed if we are not able to see keypad? Normally when we enter only we know system is armed by Red LED display on keypad. When we use our 433MHz remote to turn off alarm system, sometimes it is not disarmed and if we try to enter from Garage Alarm goes off. How to tackle this automation with showing current status of security system? I have additional trigger circuit board on the the original PCB. Which is mounted on same terminals where you installed 4 wire smoke alarm. Please help. Your video was very useful.
@PeaceThroughDeceit
@PeaceThroughDeceit 7 жыл бұрын
Also, instead of purchasing a new terminal block you can just run all wires and connect them using a wire nut and run a single wire per terminal on the keypad bus.
@butterbagboy
@butterbagboy 3 ай бұрын
nice quick no nonsense video, thanks.
@iashbanen
@iashbanen 2 ай бұрын
What does that even mean
@butterbagboy
@butterbagboy Ай бұрын
@@iashbanen it means its awesome, quick and too the point, its not 30 min long like some of these videos are, don't you like it?
@bridgetenglish6981
@bridgetenglish6981 6 жыл бұрын
Why are you not using "fire wire" I would useing terminal 9.The fire wire is a bit expensive but it fuses in heat and which in turn sets off the fire alarm. As you know Fire over rides burgular I worked for Honeywell. One great company to work for. I also made a drawing of all my installation in Home,Commercial & Industrial.So,in 5-10 years an installer would know what was run and where. I'm a lover of hard wiring,just saying as I do not like wirelass
@SulaimanTheWordSmith
@SulaimanTheWordSmith 3 жыл бұрын
My smoke alarms are wireless. How do I silence the "Fire Trouble" error I get in my Tuxedo Keypad? Do I just connect 2k resistors across the board terminals for zones that are not wire connected?
@mikec-hamilton
@mikec-hamilton 8 ай бұрын
Thanks
@blusper8348
@blusper8348 2 жыл бұрын
8worked for Honeywell .Yes a certified electronic alarm system techni ian
@blusper8348
@blusper8348 2 жыл бұрын
Female and I was A+ Conrail wanted to hire me. IM enjoying your video
@twoods_outdoors2590
@twoods_outdoors2590 4 жыл бұрын
You say the smokes are parallel but you’re saying run them all to zone one? Are you saying splice each smoke into one of the smokes wire and connect it to zone one terminal or stick each individual wire of the different smokes under the same terminals on zone one?
@CSN124
@CSN124 3 жыл бұрын
Why is it bad to place resistors in the panel. I had mine installed many years ago and the resistors are in the panel.
@johnygsh
@johnygsh 8 ай бұрын
I’m in the security field, every one has preferences on how they want it the resistors to be at I prefer mines in the panel.
@oscarromo6403
@oscarromo6403 6 ай бұрын
The resistor makes it supervised
@mrmaddocs68752
@mrmaddocs68752 Жыл бұрын
What will happen if I wire a motion detector with the resistor connecting across the MOTION TO PANEL and MOTION FROM PANEL
@blackmaxima
@blackmaxima 4 жыл бұрын
Good lord. Someone go to that DSC keypad and hit *2. Thanks for the video. I’m a senior tech looking for stuff to train a new tech who knows nothing about wiring, electricity it basic took use. I’ll see if this is useful to him.
@dronesetc9769
@dronesetc9769 11 ай бұрын
Was hoping to hear about the alarm , or rather siren connection, on my old panel it says "Bell" and then "Siren" new vista just has alarm , I'm just wondering what is connected the the "Bell " terminal on the old Brinks board?
@joefish1498
@joefish1498 6 жыл бұрын
Hello Jon.....I just moved in to a house using this exact system. I have a 2nd GE keypad at my interior garage door entrance that for some reason is disconnected at the box. I have a black ,green and white wire in the box not connected. May I ask which terminals these should be connected to. I did as much research as possible to determine why this was disconnected with no result. I need to find out for myself.
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Well the best way to figure this out would be to check how the wires connect at the keypad. The keypad will usually have the colored wires connected into terminals. These terminals will be the same at the box. There will be two for power and then one for data.
@anthonyrivera3556
@anthonyrivera3556 5 жыл бұрын
Is the long horn smoke detector or the other model of smoke detector can applicable to honeywell panel?or not?how can install it,specially in four wires?
@quansingsecuritysolution2715
@quansingsecuritysolution2715 4 жыл бұрын
I have a problem with Honeywell Vista 20P. Connection between Kickbar to Strobelight and connection to the cellphone When the kickbar is kicked, the strobelight turns on and the connection to the cellphone sometimes connect and sometimes it can't. Almost probable it can’t What is the problem and can anyone help us? Thank you
@raymondwong7401
@raymondwong7401 2 жыл бұрын
Hi, I want to wire a panic button to the panel, can you tell me where should I connect to?
@mikec-hamilton
@mikec-hamilton 8 ай бұрын
On DSC you can eliminate the resistors with a simple programming change. Will this panel do that too?
@AlarmSystemStore
@AlarmSystemStore 8 ай бұрын
The main board zones are set per zone, and expanders have a dipswitch that changes them from NC to EOL.
@dimitrikaramboulis3683
@dimitrikaramboulis3683 4 жыл бұрын
my ademco panel receives a 16V input but has an output of 7V at terminal 5 and 4. my alarm does not work. Could you give me a solution?
@copetv43
@copetv43 Жыл бұрын
My keypad won’t stop beeping do you know what this can be from?
@masona.5465
@masona.5465 6 жыл бұрын
Can you have a door contact on zone 1 and then in programming you set it as a entry delay and exit delay?
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Yes. Although Honeywell has set zone one to be a fire zone by factory default for two wire smokes; you can use other devices. The only thing about doing this is that you must absolutely use a resistor on this zone even if you're not using resistors on anything else. Thanks for watching the video. Good to have you here!
@huongyn8808
@huongyn8808 6 ай бұрын
I have a friend he wants to upgrade from DSC PC1555 to cellular primary monitor with vista 20p and 2 keypads. What to get and how to connect, could you please instruct?
@AlarmSystemStore
@AlarmSystemStore 6 ай бұрын
You can you our quote request form and we can tell you what you need. After that we can send you vids on the wiring and programming. Here's the quote req form: form.jotform.com/alarms/request-an-alarm-system-quote
@huongyn8808
@huongyn8808 6 ай бұрын
@@AlarmSystemStore I need to know before buying it from you that according to the existing DSC PC1555 hardwired, does he needed more hardwire to be wired before can use the vista 20p with cellular primary monitoring?
@AlarmSystemStore
@AlarmSystemStore 6 ай бұрын
The quote form isn't buying anything. He may need some additional wire for wiring between boards. It wouldn't be substantial though. @@huongyn8808
@heckeroffical3862
@heckeroffical3862 2 жыл бұрын
Do I need resistors for a fire alarm? Where do I put in several spectralert classics?
@tkproductions2019
@tkproductions2019 6 ай бұрын
Resistors are not needed for fire alarm notification appliances, however for initiating devices, you will need to place resistors where the wires are on the device.
@mcmcgrogan
@mcmcgrogan 3 жыл бұрын
I have a Vista 10SE System with 2 key pads, 3 door contacts and want to add 7 FG-1625 acoustic glassbreaks. The wiring is all done through out the first floor behind the walls to the control panel and labeled. I don't have enough zones left to keep them separated so do I need to bundle them with a terminal block?
@Mybrothafromanothamotha
@Mybrothafromanothamotha 4 жыл бұрын
You missed wiring the keypad which appears to be crossed, but def has different language than the panel instructions.
@user-ib6no4jy7z
@user-ib6no4jy7z 5 жыл бұрын
So it doesn't matter if the resistor goes on the high or low side of the zone terminals in the panel? I was watching another video that said to always put it to the gnd or low side???
@boboskee
@boboskee 3 жыл бұрын
Hello; I am a subscriber, and owner of a Honeywell Vista alarm panel. Would you please answer a question for me? If the Vista panel alarm goes off, and the perp leaves an alarmed door open, how long will the alarm go off without a code being entered to disarm it?
@policegaming101yt2
@policegaming101yt2 2 жыл бұрын
This is set in programming
@guesswhomartin9249
@guesswhomartin9249 3 жыл бұрын
Hey... do you happen to know ??? I have a vista 15P panel. keypad shows low battery 57. What does that mean ? I don't think its a wireless zone . keypad maybe ?
@alexandersalarms5380
@alexandersalarms5380 4 жыл бұрын
I hear a DSC keypad in the background!
@heckeroffical3862
@heckeroffical3862 2 жыл бұрын
No you don’t
@alexandersalarms5380
@alexandersalarms5380 2 жыл бұрын
@@heckeroffical3862 what
@DavidD-tx6gh
@DavidD-tx6gh 2 жыл бұрын
Can you add an outside key pad with this system?
@donhogan9585
@donhogan9585 2 жыл бұрын
Is it hard to replace a door contact
@compuven
@compuven 3 жыл бұрын
Great video.
@benkihada
@benkihada 6 жыл бұрын
I assume the door contacts are normally close?
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
They are what people refer to as normally closed, yes. When the door or window is closed then the loop is completed. When the door or window is open then the loop is open causing and alarm or fault.
@tkproductions2019
@tkproductions2019 6 ай бұрын
Would it be possible to use 2 sets of 18/2 wires and just run positive + negative + positive + negative on the keypad terminals? And if so, what order would the wires go on the keypad?
@AlarmSystemStore
@AlarmSystemStore 6 ай бұрын
Yea, you could I suppose. Not best practice to do so, but the panel doesn't care what color the actual wires are as long as each terminates to the appropriate terminal on the other end.
@tkproductions2019
@tkproductions2019 6 ай бұрын
@@AlarmSystemStore Does this mean (on the keypad) that terminals 1 and 3 are positive and 2 and 4 are negative?
@AlarmSystemStore
@AlarmSystemStore 6 ай бұрын
@@tkproductions2019 No not at all, there is only one + and -, the other two are data in this case. Polarity among all must be observed though end to end regardless of wire colors you use. The color of wire doesn't determine what goes down a given wire, what it's connected to does.
@JairMuñoz-t1o
@JairMuñoz-t1o Жыл бұрын
Por qué va haci??? No tienen continuidad la tarjeta con el gabinete
@skytouchsolutionsinc5996
@skytouchsolutionsinc5996 2 жыл бұрын
Hi. Great video. Have 2 questions. We just visited your website and noticed that you do tinker around with z-wave products. We implement a lot of 2GIG products, and for the most part, new installs are a breeze. But when taking over existing wired systems, we need to install 2GIG's takeover module. Keeping the current wired install in place, 2GIG's Takeover Kit requires only the zone wire to be removed, and leaving the COM still in the wired system. With that being said, not all boards are the same. Google brought us here, because were taking over an existing home, who had ADT, and they have the WA3000 you have above. Same exact board. You mentioned 8/9 = Zone 1, 10/11 = Zone 2, 12/13 = Zone 3, 14/15 = Zone 4 and (Question 1) is it safe to say this is a 8 Zone board or otherwise, and can you list which terminals are the zones? (Question 2), in your video, according to 2GIG's Takeover Module specs, removing the zone wire and keeping the COM in place, which terminal would be the Zone and which is the COM? In example 8/9 = Zone 1, would 8 be the Zone and 9 be the COM?
@dillonsims3398
@dillonsims3398 6 жыл бұрын
Ok so I hooked up the door contact how your video showed, using the clamp thing for the resister and wire, and followed your other video on setting up the zones but it still says fault 02, but it does chime when I open the door. I just can’t arm the system. It also says check 100rf receiver but I don’t know what that is
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Did you use the 2K Ohm resistor? Color bands on that resistor would red, black, red, and gold. As far as the 100RF that pertains to the fact that you have a wireless device programmed into the system but may not have a wireless receiver or if you do have a wireless receiver; it may not be installed correctly.
@dillonsims3398
@dillonsims3398 6 жыл бұрын
Alarm System Store I tried to match the resister to the one in the video but I must’ve used the wrong one. I’m going to switch it out, and I did have a wireless sensor programmed in because I didn’t actually realize it’s a wireless one and I don’t know how to delete that out
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
For removing the wireless device; follow the steps below: Enter programming by typing 4-Digit installer code followed by 800 When you get in you'll see '20' or 'Installer 20' At this point type *56 to go to zone programming Then you'll see 'Confirm 1=yes 0=no' Press 0 You'll then be presented with a screen that says 'Enter Zone Number' Type in the 2 digit zone number you put the wireless device on. If you put it on zone 9 then type '09' Then press * You'll see the zone programming summary Press * Then you'll see 'Zone Type' Type '00' then hit * It'll ask if you want to delete zone. Press '1' It will then kick you back to 'Enter Zone Number' Type '00' then *99 to exit programming
@dillonsims3398
@dillonsims3398 6 жыл бұрын
Alarm System Store oh my god thank you so much 😂 it finally works I’m so excited
@PeaceThroughDeceit
@PeaceThroughDeceit 7 жыл бұрын
I think it should be better explained why exactly you only put a or many 2-wire smokes on zone 1.
@chickenjoesevy
@chickenjoesevy 2 жыл бұрын
Couldn't have said it better myself
@millycarlos497
@millycarlos497 6 жыл бұрын
How you connect mini shock/vibration detector to your main box
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Is it a hardwired device or a wireless device?
@Danielson_Wax_On_Wax_Off
@Danielson_Wax_On_Wax_Off 7 жыл бұрын
I hear that DSC beeping in the background.
@heckeroffical3862
@heckeroffical3862 2 жыл бұрын
it’s not DSC
@kevinrea7820
@kevinrea7820 2 жыл бұрын
I noticed on your alarm system aluminum enclosure, you have a contact switch if it's door is opened, where does that switch wire into? And what is that switch called if I wish to purchase one? Kevin Rea Lancaster California USA
@andybowman9697
@andybowman9697 2 жыл бұрын
It is a cabinet tamper. They are out of stock at the moment, but they are here: www.alarmsystemstore.com/products/gri-tsc-20-cabinet-tamper-plunger-switch They can be connected to a zone or an or existing tamper circuit that some system have.
@marjonmotel
@marjonmotel 4 жыл бұрын
HELP HOW DO I CLEAR CODE 09 FROM MY KEYPAD.?
@jaypost965
@jaypost965 6 жыл бұрын
is there a link to the mentioned resistor video by "Jason"
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Sure! Here's the link - www.alarmsystemstore.com/pages/all-about-resistors We'll go ahead and add it in the description here as well. Have a great day!
@ggsnow2k712
@ggsnow2k712 4 жыл бұрын
I am having installation and configuration problems. My house is prewired and an old Ademco ADT system was in place. Unfortunately, I didn't have the installer code and I can seem to reset the code using the back door method. It's possible that the panel was locked out. So I bought a new Vista-21ip, thinking that I can just reconnect everything and it should work. Unfortunately, it didn't go as planned at all. I do not have a smoke detector pre-wired. So I left Zone 1 empty. When the system booted up, I got two errors. One is "Check 103 LngRng Radio", the other is "Fire code 01". I can't seem to get into the installation model with [4112]+ 800. So I moved shifted all zone connections such that Zone 1 is now connected to a door sensor. When I boot up the system, the alarm triggers, showing 'Fire 01'. I am really stuck at this moment. Hoping someone can offer some advice. Much much appreciated!
@daveintheshed4870
@daveintheshed4870 3 жыл бұрын
Zone 1 needs a 2k resistor, it can be programmed out as well. Zone 1 can be used as a door or motion but has to be programmed as much and the 2k resistor needs to be " in line" on the loop. It's designed for 2 wire smoke detectors. Put a 2k across the terminals, they come with the panel. The long range radio 103 is indicating that there is no internet connection and no resideo account established. Simply power down the panel and move the white jumper on the board. Now power up, You now have a glorified vista20. If you can't get into programming, try this. Power cycle the panel and hold the * and# keys simultaneously. If it's not locked out it will take you straight to sect 20. Then hit #20 and it will read out what the 4 digit installer code is. I realize this post is a year old already but hope that helps.
@adam29blair
@adam29blair 7 жыл бұрын
Can you add a second motion sensor. If so is it a new zone or do you put them in the same one the current motion sensor is in? Sorry if question seems dumb I know nothing about alarm panels
@AlarmSystemStore
@AlarmSystemStore 7 жыл бұрын
Hardwired devices, like motion detectors, can be wired together on one zone. Since the motion detectors are normally closed in operation you'll wire them in series if putting more than one on a zone. Most people put wired devices one per zone for ease of troubleshooting. If you have more than one device per zone then if one goes bad you'll have to check the entire run to find out which one is giving trouble.
@ianyoung5857
@ianyoung5857 8 жыл бұрын
What was the sensor that you were wiring into the door of the panel itself?
@davidmadera4470
@davidmadera4470 8 жыл бұрын
probably a tamper
@ianyoung5857
@ianyoung5857 8 жыл бұрын
Definitely some sort of a tamper. Curious as to what the actual part was. I'd love to install that on my panel.
@andybowman9697
@andybowman9697 8 жыл бұрын
It is a panel tamper: www.alarmsystemstore.com/GRI-TSC-20-Cabinet-Tamper-Plunger-Switch-p/singlegri%20tsc-20.htm
@Robert.S.806
@Robert.S.806 4 жыл бұрын
They should have a factory installed tamper switch! But no! Let's add to the cost!
@DistinctiveTents
@DistinctiveTents 7 жыл бұрын
Thank you for not installing the resistors inside the can. Too many "instructional" videos show the EOL resistor in the can!
@Timetaker1000
@Timetaker1000 7 жыл бұрын
I'm replacing a GE system with a Admeco Vista 20. House is prewired and the resistors are in the panel. Why do they need to be at the device?
@gazfrc4754
@gazfrc4754 5 жыл бұрын
@@Timetaker1000 the panel reads resistance. therefore putting the resistor at the sensor (EOL) end of line, means that if a wire was cut, the panel would read "open circuit" or zero voltage & therefore Alarm. If there was a "short circuit" (join wires together - bypass resistance) the panel would read zero resistance or full voltage (12v) & therefore Alarm, because the resistor is at EOL. Now place the resistor at the panel ......... cut or short the wires anywhere between the panel & sensor, the panel will still read the resistance and not Alarm. Noting the resistor should be in series
@bunchofbullsh7612
@bunchofbullsh7612 7 ай бұрын
Yep
@heckeroffical3862
@heckeroffical3862 2 жыл бұрын
I have 6150
@frankbuehner7880
@frankbuehner7880 6 жыл бұрын
So all this time and you don't plug it in and show that all the devices work!
@shadimurwi7170
@shadimurwi7170 2 жыл бұрын
Honeywell
@thines888
@thines888 2 жыл бұрын
haha "IS2535"
@mrmaddocs68752
@mrmaddocs68752 10 ай бұрын
What will happen if I reverse data in and data out for the keypad
@MrReckless17
@MrReckless17 6 жыл бұрын
So I have an alarm system setup but only my doors trigger the beeping when opened. All the windows in my house are hardwired but don’t beep when opened. What would I do to make those function? And which wires in my control panel would be for the windows?
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Well, you'd want to make sure the wires for those windows are hooked up to the control panel. You can get a tone generator to use to trace the wires. If you discover that they are hooked up then you'd just need to make sure that the programming is set for those zones
@MrReckless17
@MrReckless17 6 жыл бұрын
A tone generator would be able to tell me which wires are wired to the windows? Also how would I get into the setup for those zones I’m almost positive the wires are connected to the panel
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
A tone generator would help trace the wire runs, yes. You can find some here - www.google.com/search?q=tone+generator&source=lnms&tbm=shop&sa=X&ved=0ahUKEwilmNH1877aAhUReKwKHcn5D98Q_AUICigB&biw=1440&bih=769 To get into the programming sections for that panel you'd need the installer code.
Alarm System Store - All about resistors
18:19
Alarm System Store
Рет қаралды 133 М.
Adding Wired Motion Detectors to the VISTA 20P
12:09
Alarm Grid
Рет қаралды 20 М.
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 6 МЛН
Un coup venu de l’espace 😂😂😂
00:19
Nicocapone
Рет қаралды 3,9 МЛН
Honeywell Vista 20P Complete Programming
56:05
Fox Guard (Fox Guard Security)
Рет қаралды 248 М.
Alarm System Store Tech Video - Honeywell Vista Delay & Zone Programming
20:45
Series and Parallel Wiring With Alarm Systems Explained
25:59
Alarm System Store
Рет қаралды 9 М.
Complete Wiring Guide for Paradox Home Security Alarm Panel
7:22
Rigid Security Ltd
Рет қаралды 5 М.
Honeywell 4219: Setting the Address for a VISTA System
8:56
Alarm Grid
Рет қаралды 1,9 М.
Vista 20p New zone install and setup
26:40
Fix It With Zim
Рет қаралды 147 М.
How Do I Wire The Honeywell 4219 To My Vista 20P?
14:20
Alarm Grid
Рет қаралды 16 М.
Honeywell VISTA 20P vs Honeywell VISTA 21iP
6:46
Alarm Grid
Рет қаралды 26 М.