Adding / Installing a new Pylontech us3000c us5000 us2000c battery to a existing setup/stack

  Рет қаралды 32,690

Pylontech Solar Panel Battery Storage Installation

Pylontech Solar Panel Battery Storage Installation

2 жыл бұрын

In this video I will show you how to add a new pylontech us3000c or us3000c or us5000 battery to a existing battery stack or setup. Please subscribe to my channel, its important and I will make more videos. Any questions please message me.
www.premiercomputersolutions.co.uk to buy your pylontech batteries with free lifetime technical support and after sales advice

Пікірлер: 76
@dave20thmay
@dave20thmay Жыл бұрын
Just getting ready to go up in the loft after lifting a US5000 into there and checking that I'm up to speed with the connection. Found your video so reassuring to watch. Will see about posting a video of the lift by two OBE's
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 9 ай бұрын
Thanks for watching and glad you found the video useful. Please subscribe
@paultraynorbsc627
@paultraynorbsc627 Ай бұрын
Thanks for sharing 🙏
@ThePlanarchist
@ThePlanarchist Жыл бұрын
Brilliant, thanks for this, most useful and much appreciated. Cheers!
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Thanks please subscribe. I’ll make more videos if people need help but please keep subscribing. Glad the videos are useful and help people
@HarryE1969
@HarryE1969 2 жыл бұрын
Thank you for the concise explanation!
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Thanks for watching.
@frankieclifford
@frankieclifford Жыл бұрын
Thank you so much for this, have had system in place for 1 year, now going to expand storage, very informative and understandable video, thanks again - Frankie
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Thank you for subscribing and your kind words. I appreciate all my subscribers and i am glad my videos help you.
@davidaliperti
@davidaliperti Жыл бұрын
Thanks for sharing, i am still confused about if diying a battery with cells bms etc or buying a prebuilt like this.
@Gorblaou
@Gorblaou Жыл бұрын
Thank you for the video. I have 4 US2000C and I'm thinking about ading a US3000C or a US5000C.
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
No worries I would go for a us5000, more capacity a 4.8kw and more load at 100amp. Www.premiercomputersolutions.co.uk have the pylontech us5000 in stock
@mollyfilms
@mollyfilms Жыл бұрын
Thanks for the video. One question if I can? Do you need to let the inverter know you now have more capacity? I seem to remember this was set at the time with my original set up a few years ago. I’m about to add 2 new batteries to my stack.
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
No the inverter should detect more new batteries in the stack automatically. It will tell you in aH what the capacity is. For example , if you have 2 x pylontech us3000c at 75aH each , then add another us3000c then you have a new total of (3 x 75) , 225 aH capacity which the inverter should report. Sometimes it says 222 aH but don’t worry about that it’s never exact.
@philiploizides4366
@philiploizides4366 Жыл бұрын
Excellent video, it really helped a lot, just one quick question, is the positive from the inverter always connected to the master battery...I have four batteries which all seem to be fine but the black negative is connected to the master.
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
It can either be to the master or to the last battery in the stack. As long as positive is at one end and negative is at the other end to achieve a parallel connection. Polarity does not matter. So the master could have the negative or positive . Thanks for watching video , I am glad the videos are helping people and thanks for subscribing.
@philiploizides4366
@philiploizides4366 Жыл бұрын
@@pylontechsolarbatterystora3979 Thank you very much for your prompt reply
@YusufHargey
@YusufHargey Жыл бұрын
Hi I was wondering if you help. I have a Goodwe ES 4.6 inverter with 2 x UP5000 (pylontech) batteries. Can you please advise what the DIP switch setting should be? Does it matter? My installer used very specific switch settings but I can't find any reference for it. I am asking because I want to expand my battery pack to 3 units. Please advise.
@gowithgerdrivingschool8552
@gowithgerdrivingschool8552 Жыл бұрын
Thanks for this. Do you know if you can mix different capacity pylontech batteries? I currently have 2 x USC2000 batteries and want to add an additional 2 x US5000 to the system to triple my storage capacity from my Solar Edge inverter!
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Hi yes you can mix them. The BMS of the master battery which you’ll need to set to one of the new us5000 batteries. So the master battery must be a us5000 in this setup.
@horstschafer2378
@horstschafer2378 Жыл бұрын
Very good explained! At any point in time your system is designed such, that all these batteries are discharged with a constant rate not exceeding 100 A, right?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
The inverter and internal BMS manage the charging/discharging so batteries all charge and discharge at the same rate. So the more batteries you have the more FREE solar energy from the sun you can store. Especially in these hard times and cost of living crisis with electric bills to exceed £6000 per year , so if you invest in solar battery storage you will get your investment back in 1 year and the batteries have a lifespan of 10 years. So well worth it.
@sahisa
@sahisa Жыл бұрын
After adding 2 new US3000c batteries to me my existing 3, do I need to change any settings on the inverter to ensure I am charging to the max 17.75kw capacity?
@avechristusrex31
@avechristusrex31 6 ай бұрын
Are you sure you don’t need to balance the charges before connecting to the inverter?
@MinoManekshaw
@MinoManekshaw 9 ай бұрын
Hi and many thanks for the video - I have a stack of seven 2000's to which I need to add a 5000. I understand that the 5000 has to become the new master - the question is, how is the new stack balanced when there is a mixture? I was told that I had to first fully charge my stack of seven 2000's and then separately charge my 5000 before adding the 5000 to the stack. This sounds awfully laborious and long winded so is there a neater, simpler way please?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 9 ай бұрын
No all you need to do is connect the us5000 set it as a master. Turn the battery’s on, sync them . Then let them balance naturally. Don’t turn your inverter on at this stage. After a couple of hours the bms in the master battery will store the charge state of the other batteries. At this stage turn on the inverter and use as normally. Eventually when there is no sun or extra charge the batteries will reach there minimum SOC and then they will be balanced . No need to charge them up individually, so backwards!
@maximus4621
@maximus4621 Жыл бұрын
I have 3 batteries. While I'm working off batteries, just 2 of them are flashing with all green lights. The one that is in the middle is just flushing "run" only. I do think that power is drained from 2 batteries that Victron is connected to with plus and minus. Is that a problem?
@marcellobacci7789
@marcellobacci7789 Жыл бұрын
Very interesting video, thank you, I would like to ask a question; if the solar panels fail to charge the batteries, could they be charged with a charger connected to a generator set ??and how??
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
You would still need a charge controller. But in principle yes they can be charged from a generator
@jbbcoral66
@jbbcoral66 Жыл бұрын
hi.. thanks for the time you spend on the videos for us.. if i want to raise my Battery capacity can i use a 3000 or 5000 in an 2000 system or must i stay with 2000???
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Thanks for watching videos, please subscribe. You can interchange us3000, us5000, us2000c, all together and have a mixed setup. No need to stick with one model type.
@jbbcoral66
@jbbcoral66 Жыл бұрын
@@pylontechsolarbatterystora3979 perfect.. thank´s
@cassandracurse7065
@cassandracurse7065 Жыл бұрын
Awesome vid mate exactly what I need ... Question...I have 3 x 2000 batteries at present and am going to add another 3000 is it neccessary for the 3000 to be the master?.... also my 3 have been stacked ontop of one another at install same question,... is it neccessary for the 3000 to be at the bottom? as it is the heaviest at 32kg?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Put 3000 at the bottom . Also it needs to be set as master. You can have upto 8 batteries stacked on top of each other , pylontech says
@cassandracurse7065
@cassandracurse7065 Жыл бұрын
@@pylontechsolarbatterystora3979 superb thanks so much..I'll be watching you and following now ...cheers
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
@@cassandracurse7065 please subscribe to the channel for more new videos coming up
@ricobass0253
@ricobass0253 5 ай бұрын
When and how do you switch the inverter on and off?
@moorsidefarmhousecottage4663
@moorsidefarmhousecottage4663 Жыл бұрын
thanks for the video, i have a question I have 2 us 3000 in parallel linked up to my solar inverter, I am about to add a wind turbine with a separate charge controller to my system but cant figure out how to connect both the solar and wind cables to the battery as there is only one connector for positive and negative, any suggestions? thanks
@rogereverett9095
@rogereverett9095 Жыл бұрын
in my system I have batteries connected via victron distributor to my inverter. You could connect your wind charge controller there. ie midnite classic, but you need to play around with charge settings so that midnite is always slave to solar.
@williemusopole4542
@williemusopole4542 Жыл бұрын
Hello Sir, I got the US3000C batteries (two) and unfortunately I connected them to an inverter that seems to be incompatible with the system as a result the batteries have gone into safety(sleep)mode and I don't know how to go about it from there, please assist me.
@sublimejazz8207
@sublimejazz8207 9 ай бұрын
Can only one of these batteries alone work on a 5kva inventor? If yes, how do you connect it
@gwenc8900
@gwenc8900 Жыл бұрын
So, what are the dips made for ?!
@phonologyfreaks
@phonologyfreaks 6 ай бұрын
I just added a 3rd us3000c battery in my stack, all 3 are the same model. However, when balancing them, 2 seem to get balanced and go on standby while the third keeps all lights turned on. No blinking. I waited for approx 3 hours already and it remained like that. Would you know what could be causing it or if can just go ahead and plug everything in to the inverter?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 6 ай бұрын
You need to run them with the inverter and discharge them to a 0 state . Then when they recharge they will be balanced
@MinoManekshaw
@MinoManekshaw 9 ай бұрын
I currently have a single stack of seven 2000's which the installer set up. In studying the PylonTech installation manual, it says not to stack them directly one upon another and even when using their super-expensive brackets, it says a maximum of four! Have you ever heard if or experienced. any problem with stacking?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 9 ай бұрын
Stacking upto 4 on top of each other is fine. Even when using brackets the benefits are negligible. In a us2000c manual , it says 4 can be stacked on top of each other. But if you are uncomfortable then you can vertically stack them making sure they are secured at the top and bottom.
@rupey
@rupey 9 ай бұрын
Do they have to be earthed? I have 2 no. 3000 and they're not earthed and Im having problems ballancing them, thanks in advance.
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 9 ай бұрын
Yes all batteries have to be earthed
@jeffpedley2109
@jeffpedley2109 5 ай бұрын
The new master battery has been fitted and all wired up but when I turn on the batterys all the LEDs on the new battery stay on have you any idea wy
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 5 ай бұрын
Maybe the new battery has not been fitted correctly
@gheorgheciuciu6374
@gheorgheciuciu6374 Жыл бұрын
Hi,you can tel me please, when we must change the position of the four ADD Switches,thanks.
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Only when using rs485 protocol , the ADD switches are used
@rogereverett9095
@rogereverett9095 Жыл бұрын
when using rs485, ie voltacon inverter, dip switch set on master for 1st array 2nd etc . 1st array 0001, other batteries on array 0000
@EpicWinz
@EpicWinz Жыл бұрын
Can I mix a US3000C into a system with 2x US2000B Plus in the same way as you describe?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Hi, yes you can as I have had these 2000b and us3000c working together. . You’ll need to change-your lead to the inverter to have the US3000C . The lead is available from premier computer solutions, call them .
@andyfraser5876
@andyfraser5876 Жыл бұрын
I have a single US3000C battery with a Sofar HYD 3000-ES hybrid inverter. The battery specification says it can be 95% discharged, but the Sofar will only allow 85%; is there a way around this, or do we need to wait for an inverter firmware update?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
You need to update the firmware, a later version has been introduced to allow 95% DOD from 85% currently
@andyfraser5876
@andyfraser5876 Жыл бұрын
@@pylontechsolarbatterystora3979 I've looked on the Sofar website, but no updates are shown. My inverter is very new, it arrived about 3 weeks ago, so I would expect it to have the latest firmware.
@andrewl9020
@andrewl9020 Жыл бұрын
It may also be down to the SOC settings within the inverter that you should be able to change yourself. My Solis inverter was set to 80% originally. However the inverter companies, like Solis advise against setting it to 95% to prolong the life of the battery.
@andrewl9020
@andrewl9020 Жыл бұрын
The SOC is the minimum it can go down to so 10 = 90% DoD at least on Solis inverter
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
@@andrewl9020 yes 90% is a good SOC limit . Depends on your inverter and if you have the latest firmware.
@leeebbrell9
@leeebbrell9 Жыл бұрын
Will they self balance or do you need to balance them 1st
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
They self balance and best to let them do it .
@mb-3faze
@mb-3faze Жыл бұрын
@@pylontechsolarbatterystora3979 When connecting the new battery, the batteries will certainly balance - but only the voltage will balance. The SOC, which is the data that is fed to the inverter/charger will be the average SOC of the pack. The SOC is calculated value based on the voltage drop given a certain charge delivery. As such the individual batteries can be quite different when it comes to SOC levels. It's probably best to check the capacity and SOC levels on each battery. This can be done with Pylontech's BatteryView sofware (PC based) or MultiSIBControl's graphical software which is pretty good. All you have to do is make a cable connecting the Console port on the battery to the PC and run the software. If interested I will send a link to the simple youtube video showing how I did this task.
@TheRosiebeam
@TheRosiebeam 9 ай бұрын
How long did equalisation take?
@TheRosiebeam
@TheRosiebeam 9 ай бұрын
He's charging 15€ per question. I wouldn't pay it. He didn't even finish the job. Turning them back on and saying job done isn't accurate
@richlee5516
@richlee5516 Жыл бұрын
Great system, however consider that the link cables between batteries and especially important, the long Pylontech Inverter cables must not exceed a constant 100A, due to both connector and cable ratings. They can briefly go up to 125A for a short time. I am not an electrician, but have read quite a lot about high current DC storage designs. Now my concern, (not sure if I could see this correctly) you appear to have a large system connected in parallel with only a single cable providing battery power to inverter. That means you can only draw 100A / 7(number of batteries) = 18.29A per battery before you exceed the cable rating. That is just 978W per battery. Your system potentially exceeds that easily the way it is connected, unless you have fuses protecting that cable with a 100-125A fuse, and a limit on the inverter/charger. To solve this, either use a small inverter maximum 100A, or a better solution, buy extra Pylontech long cables and wire in parallel to a high current bus bars for both live and neutral, then come off that with a higher rated cable towards fused inverter cables. Theoretically then you can go right up to the full massive rating that these batteries can supply. To enhance, try to ensure the batteries are fused before they reach the busbar also. That can be achieved with modified Victron Lynx Power In modules that are rated up to 1000A. KZbin has some good videos how to add fuses. Please check your inverter and batteries aren't exceeding all those cables.
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 Жыл бұрын
Hi Rich. The inverter cables are 2m , 100amp so all good. No problems at all. Been working well. Thanks for subscribing. Keep watching the videos
@rogereverett9095
@rogereverett9095 Жыл бұрын
agreed, I run a 6 us5000 with victron bus bars but before then could often see 118amps on those long cables. The other alternative is another set of long cables run parallel to the other connections on Pylontech, as per pylontech manual.
@muso31
@muso31 11 ай бұрын
Correct on these comments. The cables used are under spec in this setup. What I don't understand in the pylontech manual, is do you have to use multi group mode (A positive cable to the bus bar per battery) if you have more than one battery? Or is there another way using just one positive and negative cable?
@richlee5516
@richlee5516 11 ай бұрын
@@muso31 No it is not a multi group mode. I believe that is when you have multiple groups, where each group has several batteries. I have 6 x US5000 and there is one inverter RS485 communication cable to battery 1 then they daisy chain linked through each battery. This has worked just fine. Each battery has it's own Pylontech long cable to NH fuse (100A but you can reduce to 80A) before ending up at a large chunky bus bar.
@muso31
@muso31 11 ай бұрын
@richlee5516 this is great thanks. I assume the 100a fuse is on the positive lead only?
@DecoD71
@DecoD71 6 ай бұрын
can you add a 3000 to a us2000?
@pylontechsolarbatterystora3979
@pylontechsolarbatterystora3979 6 ай бұрын
Yes.
More Communication, More Power | The Pylontech Low-Voltage Combiner Hub
10:42
Intelligent Controls
Рет қаралды 2,5 М.
He sees meat everywhere 😄🥩
00:11
AngLova
Рет қаралды 8 МЛН
Sigma Girl Past #funny #sigma #viral
00:20
CRAZY GREAPA
Рет қаралды 23 МЛН
Wait for the last one! 👀
00:28
Josh Horton
Рет қаралды 108 МЛН
Adding a new Pylontech US2000 battery to my home energy storage.
16:48
Nicholas Howell
Рет қаралды 58 М.
Installing Pylontech US3000C Batteries
26:52
Ben's Garage
Рет қаралды 50 М.
Pylontech Battery Firmware Upgrade How To US2000C / US3000C
21:34
Help Dr Solar resolve the Pylontech LV Hub comm issues.
6:19
Dr Solar @AWPS Renewable Energy, LTD
Рет қаралды 16 М.
Add additional Pylontech batteries to an existing battery bank
6:08
Zayd’s House
Рет қаралды 52 М.
Pylontech battery very degraded.
20:33
Nicholas Howell
Рет қаралды 38 М.
Installing Pylontech US2000B / US2000C Solar Batteries #0047
12:27
Make Or Repair
Рет қаралды 16 М.
Www.premiercomputersolutions.co.uk, Balancing pylontech batteries, fault finding, fixing overload
6:50
Pylontech Solar Panel Battery Storage Installation
Рет қаралды 3 М.
Pylontech Cabling Master Class
13:05
Intelligent Controls
Рет қаралды 6 М.