Ademco Vista 15p Test 13 *PANEL CRASHES*

  Рет қаралды 13,794

FireAlarm9200

FireAlarm9200

Күн бұрын

Пікірлер: 54
@lazyraccoon3017
@lazyraccoon3017 Жыл бұрын
The 299 has gotta be the scariest siren driver ever
@Alarmo05221
@Alarmo05221 Жыл бұрын
Scary enough for a intruder to get out.
@meechmushrooms
@meechmushrooms 3 жыл бұрын
After about the 3rd time setting that off, my parents would have _killed_ me. Lol
@andrew_radios_speakersandmore
@andrew_radios_speakersandmore 2 ай бұрын
"You ave violated a proteted awea da powece wuh cawed leave immediately"
@vvv331
@vvv331 2 жыл бұрын
5:35 tfw voice driver turned into machine gun
@FireAlarm9200
@FireAlarm9200 2 жыл бұрын
AHHHHHHH
@SkyRBLX320
@SkyRBLX320 2 жыл бұрын
Yes so funny 😂😂
@KevinLyons-gn7eu
@KevinLyons-gn7eu 3 ай бұрын
@@FireAlarm9200 who is the voice of that ademco talking siren speaker ?
@therealstrike.
@therealstrike. 3 жыл бұрын
Panel when alarm: EEEeeeEeEEEeEeEEEEeEeE Panel during the middle of alarm: EeEeeEeEe- -dies
@blackmaxima
@blackmaxima 3 ай бұрын
So, on these panels, when they’re in alarm, bell output power comes straight out of the battery. This is actually pretty standard for security panels. I’ve seen panels with a high load on the bell output, cause the whole panel to shut down on alarm. That siren driver eats a lot of current too and it’s putting quite a draw on the battery. There are ways to wire speakers on a driver to budget the amount of current the driver draws, usually by putting speakers in series instead of parallel. The battery is discharging quickly when it’s in alarm. A sure sign that the battery is past its service life in AH capacity. I’d check the current draw out of the bell output and make sure it’s not beyond what the panel specified. I’d also go for a new and larger capacity battery. Just because the panel doesn’t show battery trouble, doesn’t mean the battery is actually good in terms of AH capacity.
@Alarmo05221
@Alarmo05221 2 ай бұрын
That is why I use a 7amp hour battery. It may sound the same but it works with the VS279 and VS299 that have shown that they crash panels whenever they want to with this dude, no issues for me, just trying to get rid of the supervision issue on my panel
@officialoofyt
@officialoofyt Ай бұрын
I agree with you. My battery *cables* stopped working (the battery is fine) and then since theres no battery my panel just sounds the siren for two seconds then goes into bell failure. However I found out that if I spam the panics the siren will eventually start going off from the transformer
@sarosvideos4429
@sarosvideos4429 Жыл бұрын
5:00 You can hear it winding down to beeps.
@farx4070
@farx4070 4 ай бұрын
Yeah 100% need a bigger PSU. You can hear the siren frequency dip once the announcer kicks on. Telltale sign of inadequate power
@willsarms3
@willsarms3 3 жыл бұрын
you should run the voice driver off of an external power supply to not suck up the panel power, I use an old Roomba charger with the 4204 relay module for my fire alarms.
@SodiumInduction-hv
@SodiumInduction-hv Жыл бұрын
Wdym? How do you attach a charger to a 4204
@willsarms3
@willsarms3 10 ай бұрын
I connected the positive output of the charger to a relay input, the charger negative to all the alarm negatives, the alarm positive goes to the N.O. side of the relay@@SodiumInduction-hv
@SodiumInduction-hv
@SodiumInduction-hv 10 ай бұрын
@@willsarms3 you could just run wire from positive terminal to alarm and negative terminal to alarm for 4204
@DanknDerpyGamer
@DanknDerpyGamer 4 ай бұрын
5:35 sounds like it's trying to begin tap dancing. 😂
@NyxKemo
@NyxKemo 3 жыл бұрын
The security system at my school is old and keeps crashing and each time it boots back up the siren goes off cause its a DSC system
@connordiana5713
@connordiana5713 3 жыл бұрын
That est is loud I had my AirPods in it did not sound to good
@CaptianGamerDude
@CaptianGamerDude 2 ай бұрын
Welp… it’s been one of those days
@matrix2048
@matrix2048 5 ай бұрын
Some part of me wants to think it had something to do with the battery, but I can't really be sure.
@mackgames2000
@mackgames2000 Ай бұрын
Bro thats so freaking loud 7:53
@The-creator-of-good-videos-15
@The-creator-of-good-videos-15 4 ай бұрын
2:02: I think my previous school’s fire alarm sounded like that or something, but higher-pitched or something… Idk.
@Mizu14.
@Mizu14. 3 жыл бұрын
It was repeating in my head and i got scared... but i just played music and it went off... why was it repeating in my head?? Because he kept looping the alarm over and over
@Mizu14.
@Mizu14. 3 жыл бұрын
I am scared of alarms
@babybert26
@babybert26 26 күн бұрын
3:16 PANEL BROKEN 😓
@lift_brisll
@lift_brisll 3 жыл бұрын
Where did you get the sound I want to download it from my system
@CrowJamz
@CrowJamz 3 жыл бұрын
its not a sound, its a sound driver (which just means it makes the sound on its own)
@lift_brisll
@lift_brisll 3 жыл бұрын
Okay
@officialoofyt
@officialoofyt 3 жыл бұрын
Finally early
@JHZ_7908
@JHZ_7908 3 жыл бұрын
5:15 it crashed
@JHZ_7908
@JHZ_7908 3 жыл бұрын
@Nevan Newaz's Gaming, Vloggs and more ik
@thatonecanadian.7102
@thatonecanadian.7102 Жыл бұрын
5:00 nah it crashed earlier, you can hear the panel dieing when he opens the door. And then at 5:15 the panel got low pitched and did 6 beeps seconds after. Tangled that siren needs to be on the external power supply so it doesn’t fuck up the panel like that.
@squdineycarolsims4825
@squdineycarolsims4825 3 жыл бұрын
Omg the sound of the ingerity sounded different
@BRISTOLFORCE2009
@BRISTOLFORCE2009 2 жыл бұрын
It’s not an integrity that’s why
@Alarmo05221
@Alarmo05221 Жыл бұрын
@@BRISTOLFORCE2009 there is a model of the integrity that sounds like that, but this alarm is a pre integrity.
@siphonralarms9411
@siphonralarms9411 3 жыл бұрын
Another panel crashing eh??
@FireAlarm9200
@FireAlarm9200 3 жыл бұрын
I’m blaming you.
@siphonralarms9411
@siphonralarms9411 3 жыл бұрын
@@FireAlarm9200 I’m blaming the power supply 😂
@Chubb._.12._.c._.official.us.1
@Chubb._.12._.c._.official.us.1 3 жыл бұрын
Lol 😂
@timeylies
@timeylies 3 жыл бұрын
wat.. it keeps crashing?
@matthewantonucci6751
@matthewantonucci6751 3 жыл бұрын
Hey Garrett why'd you remove The Notifier AFP-100 Test 7 video?
@FireAlarm9200
@FireAlarm9200 3 жыл бұрын
It had an issue rendering and I didn’t notice till the premiere ended early. It’s getting reuploaded.
@matthewantonucci6751
@matthewantonucci6751 3 жыл бұрын
@@FireAlarm9200 Thank you Garrett and when are you gonna reupload that Alarm Video?
@squirrelnutz2209
@squirrelnutz2209 5 ай бұрын
5:32
@Chubb._.12._.c._.official.us.1
@Chubb._.12._.c._.official.us.1 3 жыл бұрын
First
@mattdude
@mattdude 3 жыл бұрын
Why did it say alarm zone 00?
@SBLN_games
@SBLN_games 2 жыл бұрын
I think it had to do something with the panel crashing and rebooting... I've never seen that before.
@AA-777-
@AA-777- Жыл бұрын
@@SBLN_games I haven’t seen it as-well, but maybe if he hooks up a 6160 he could (or we) could see what zone 00 is atleast the name of it if it even has one
@mrmaddocs68752
@mrmaddocs68752 Жыл бұрын
The control panel when alarm: REEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE The control panel during alarm: REEEEEEE-dies Keypads when alarm: 13 AC STAY CHIME ALARM INSTANT Keypads during alarm: 1 A TAY E AL INST Then it dies
@alanhammersley5014
@alanhammersley5014 2 жыл бұрын
Absolute rubbish kit. Installed 4110s and 4140s and they were awful. Metal back plates on the 4140 and plastic covers.
Ademco Vista 15p Test 16 (ELK-110)
9:13
FireAlarm9200
Рет қаралды 10 М.
Ademco Vista 10se Test 22: The Last Test (Ft. Safeman4202)
9:13
FireAlarm9200
Рет қаралды 10 М.
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 73 МЛН
When you discover a family secret
00:59
im_siowei
Рет қаралды 34 МЛН
❌Разве такое возможно? #story
01:00
Кэри Найс
Рет қаралды 7 МЛН
Correcting Misinformation Around International Emergency Alert Systems
25:11
Ademco Vista 15p Test 14
10:32
FireAlarm9200
Рет қаралды 4,2 М.
Simplex 4008 Test 1: My New Voice Evac System
13:05
Equalstar's Alarms
Рет қаралды 1,2 М.
10 VS 10,000 Piece Lego Plane Crash IN POOL
15:42
supersnailboy
Рет қаралды 220 М.
Security System Test 10: ADT Safewatch Pro 3000
8:51
FireAlarm9200
Рет қаралды 78 М.
Reporting Formats Compilation
4:17
NewAgeServerAlarm
Рет қаралды 3,6 М.
Honeywell/Ademco Vista 20p Test 12: The voice siren
12:07
EYL8902 Alarms
Рет қаралды 37 М.
Warning System Broadcasts (EAS) Throughout The World
18:46
11Cent
Рет қаралды 6 МЛН
Honeywell/Ademco Vista 20P Test 6: New zone
7:29
EYL8902 Alarms
Рет қаралды 3,6 М.
Siemens Cerberus Pyrotronics MXLV Fire Alarm System Test / Demonstration
9:01
Fire Alarms of Northeast Kansas
Рет қаралды 460
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 73 МЛН