its basic concept of VFD,AC,DC DRIVE acceleration and deceleration time,rate and importance of both of them,
fault due to wrong acceleration and deceleration time setting,
basic understanding of Ramp up,Ramp down, over voltage fault,over voltage tripping,under voltage tripping and fault possible reason...
share this video with freshers of electrical engineering and Automation engineering people...
speed and torque mode of VFD
• 🔴Speed and torque mode...
DC bus regulation video link
• 🔴DC BUS VOLTAGE REGULA...

Пікірлер: 57
@farukpatel3049
@farukpatel3049 4 жыл бұрын
DC BUS OVERVOLTAGE NICE EXPLAIN
@rizwanwaqas9460
@rizwanwaqas9460 Ай бұрын
Very good Nice explain Sir
@nagireddisivaganesh4784
@nagireddisivaganesh4784 3 жыл бұрын
Thanks sir 🙏 Bahut badiya samjaya
@vishalgovekar6369
@vishalgovekar6369 4 жыл бұрын
Nice explain sir ji
@AshrafKhan-dg3tv
@AshrafKhan-dg3tv 6 жыл бұрын
Very good information in this video sir
@AmitKumar-ge7lj
@AmitKumar-ge7lj 6 жыл бұрын
Nice video sir is video s muje bhut fault clear hu h thanks
@aforautomation
@aforautomation 6 жыл бұрын
thanks for watching, keep in touch brother
@labibahmed6140
@labibahmed6140 4 жыл бұрын
goooooooooooood and niceeeeeeeeeeeeeeeeeeeeeeeeeee.
@inspirationinabox4932
@inspirationinabox4932 4 жыл бұрын
It’s really use full content thanks you 👍
@abhitrivedi6861
@abhitrivedi6861 4 ай бұрын
Sir servo motor explain karo ,, position accuracy kaise achieve karte hai and usme acceleeation time jyada hota hai yo kya effect hota hai position pe
@surendrasingh-me3hf
@surendrasingh-me3hf 6 жыл бұрын
Superb teaching. Superb explanation sir.
@aforautomation
@aforautomation 6 жыл бұрын
thanks surendra
@sanjeebbadaik2912
@sanjeebbadaik2912 4 жыл бұрын
Thanks Sir 👍
@labibahmed6140
@labibahmed6140 4 жыл бұрын
nice bro
@PankajTiwari-di1zq
@PankajTiwari-di1zq 6 жыл бұрын
Sir thank u so much for this kind of vidio on drives......your explanation is very clean and easy to understand......specially i like to listen "theeek hai n" from u after every sent.....😍😍😍😍😍......nd sir plz make a vidio on master slave drive configuration......how we can operate two drive as master slave .......once agian thankxxxx......
@aforautomation
@aforautomation 6 жыл бұрын
😁😊😊 welcome brother
@Lopanfernando
@Lopanfernando 5 жыл бұрын
Well done sir....I understood
@aforautomation
@aforautomation 5 жыл бұрын
thanks and watch all the videos they'll be helpful for you
@Lopanfernando
@Lopanfernando 5 жыл бұрын
@@aforautomation yes sir
@jasinaj5397
@jasinaj5397 6 жыл бұрын
nice explanation
@abhishekrana3243
@abhishekrana3243 4 жыл бұрын
Sir please make a video of harmonics and why we use more 6, 12 or 24 pulse drive
@rishikeshsharma5651
@rishikeshsharma5651 4 жыл бұрын
Sir, can you please make a video about of regeneration braking
@mohdrazaansari6980
@mohdrazaansari6980 6 жыл бұрын
V good sir
@prosanjit_saha_jeet
@prosanjit_saha_jeet 3 жыл бұрын
Thanks sir. push battom se friquency slowly and firstly com jada kayse karsakta hey
@aforautomation
@aforautomation 3 жыл бұрын
Push button se 2 DI connect karo aur DI k function me MOP inc aur decrease set karo, speed reference source ko terminal set karo,ho jayega
@mubarishussain3696
@mubarishussain3696 5 жыл бұрын
very good video. Much appreciated .Thik hai na 50 times
@aforautomation
@aforautomation 5 жыл бұрын
Hahaha. thanks brother
@desertrosewazir
@desertrosewazir 5 жыл бұрын
Thanks for the brilliant video. What is the cause undervoltage during deceleration..
@aforautomation
@aforautomation 5 жыл бұрын
Undervoltage during deceleration may be due to excessive braking current if DC braking is used or dynamic braking parameters are not set properly.if parameters are okay then there may be problem in braking IGBT of DBR.
@kuldeepjangra1868
@kuldeepjangra1868 5 жыл бұрын
Sir thank you so much
@nitinmaind8967
@nitinmaind8967 4 жыл бұрын
Voltage increase karenge toh current increase hoga ,and speed achived hoga toh current Kam kaise hot hai ??
@shashankkumar7770
@shashankkumar7770 4 жыл бұрын
Sir our drive tripping of crane application DC link overvoltage..we have applied dbr unit ..still sometime
@aforautomation
@aforautomation 4 жыл бұрын
increase de-acceleration time or tune motor with drive.You can use DC braking for better performance.
@FirozKhan-xc1ib
@FirozKhan-xc1ib 5 жыл бұрын
Nice
@aforautomation
@aforautomation 5 жыл бұрын
thanks brother. please view all videos they'll help you. please share with your friends who need this type of videos.
@debabrataswain350
@debabrataswain350 6 жыл бұрын
Sir,Good explanation Esa drive ke bare me or parameters ke bare me or vi topic me video banaiye plz Good job sir Thanks
@aryastudio28
@aryastudio28 6 жыл бұрын
Sir please abb dvire ki parameter ke manual per video upload karna jaise kaise number me kaisa perameter set Kiya jata hai
@aforautomation
@aforautomation 6 жыл бұрын
okay i will make
@reeshikeshmahato962
@reeshikeshmahato962 4 жыл бұрын
Sir my ABB 550 drive take a lot of time for start and stop ..tell me parameter for rectification..is this problem on acceleration and deacceleration time
@aforautomation
@aforautomation 4 жыл бұрын
yes its due to Acceleration and deceleration time but if you reduce time DBR will be required otherwise drive will trip on overvoltage fault.
@deviprasadpattanaik4634
@deviprasadpattanaik4634 6 жыл бұрын
Sir please give us a class of scalar mode vs dtc mode of a drive.
@aforautomation
@aforautomation 6 жыл бұрын
next video will be vector control concept
@deviprasadpattanaik4634
@deviprasadpattanaik4634 6 жыл бұрын
A For Automation ok..sir
@pardeepsharma8657
@pardeepsharma8657 4 жыл бұрын
Sir my 250 kw ABB ACS-850 Drive is tripping on DC over voltage on every minor voltage flauctuation. What is parameter for auto restart for ABB acs 850 ? Even others sinamics vfds of same rating doesn't tripped.
@aforautomation
@aforautomation 4 жыл бұрын
Have you connected brake resistor to drive if yes then enable par 48.01. if not then enable par 47.01
@aforautomation
@aforautomation 4 жыл бұрын
to auto reset the overvoltage fault bit number 1 of par 32.01 shoul be 1
@labibahmed6140
@labibahmed6140 4 жыл бұрын
if english subtitle, then i think your video will be see many many people
@nageshpandey5333
@nageshpandey5333 5 жыл бұрын
Sir drive mein two or more aacleration and deceleration time q diya rehta hai
@aforautomation
@aforautomation 5 жыл бұрын
drive me 2.acceleration time rahta hai use jab chaho select kar sakte ho ek digital input deke ya plc se digital input deke bhi.application k according selection kar sakte hain.
@dipakchate.
@dipakchate. 3 жыл бұрын
Sir vfd me lvd and lva error atta he how to solve
@aforautomation
@aforautomation 3 жыл бұрын
kon sa drive hai?
@dipakchate.
@dipakchate. 3 жыл бұрын
Vfd cx
@dipakchate.
@dipakchate. 3 жыл бұрын
AC drive
@ebenezertawiah379
@ebenezertawiah379 4 жыл бұрын
Sir kindle help us in translation to English
@shashankkumar7770
@shashankkumar7770 4 жыл бұрын
V/f value in drive
@deepakrawat4997
@deepakrawat4997 3 жыл бұрын
Nice
Properly Sizing Line Reactors for VFD Applications
27:15
Hammond Power Solutions
Рет қаралды 10 М.
Wednesday VS Enid: Who is The Best Mommy? #shorts
0:14
Troom Oki Toki
Рет қаралды 50 МЛН
Thank you mommy 😊💝 #shorts
0:24
5-Minute Crafts HOUSE
Рет қаралды 33 МЛН
«Жат бауыр» телехикаясы І 26-бөлім
52:18
Qazaqstan TV / Қазақстан Ұлттық Арнасы
Рет қаралды 434 М.
🔴Speed and torque mode of vfd (हिंदी में)🔵
14:18
A For Automation
Рет қаралды 39 М.
Top 5 Incredible Used Radios - Featuring Icom IC-7851
12:21
ML&S Martin Lynch and Sons
Рет қаралды 2,6 М.
🔴Motor control methods used by VFD or AC Drive(In Hindi)🔵
11:15
A For Automation
Рет қаралды 24 М.
Wednesday VS Enid: Who is The Best Mommy? #shorts
0:14
Troom Oki Toki
Рет қаралды 50 МЛН