Sir, please tell me whether it is necessary to change any parameters in the DC drive to get pulse signal from A_ and B_ in the encoder or will the drive run without any problem by connecting these in place of A and B wires?
@aforautomation28 күн бұрын
It will run without any problem
@askarindamroyАй бұрын
Very Informative video. 😊
@arvindkumarkumar59342 ай бұрын
Autotune but overshoot. Eurotherm
@aforautomation2 ай бұрын
Decrease the gain and try manual tune.
@rakeshverma-lr6pf2 ай бұрын
Sir Tia portal ke upar video banaye s
@arakerielectricalindustrie15462 ай бұрын
Fekadu 😂
@arunpaul61952 ай бұрын
Sir, when stop button from scada is pressed continuously the motor come to stop when rpm goes down. When button is released it runs again what may be the cause
@aforautomation2 ай бұрын
Start command in continously high from PLC or Hardwiring and Start stop parameter needs to be check.
@ashvineborade42992 ай бұрын
अदभुत विस्तार से बताया है,धन्यवाद
@car91672 ай бұрын
Can the formula at 8:00 be used for output reactor (from VFD to motor)? What frequency do you use? My motor goes from 3000RPM to 18,000RPM (so 50Hz to 300Hz). Do you use 300Hz for calculation?
@httrelectronic60823 ай бұрын
Why not drive trip in unbalanced??
@pixeledgeautomation77483 ай бұрын
Sir ji Siemens ka kya parameters hai
@anshultiwari9223 ай бұрын
plz send pid sheet link
@samiullahchohan77623 ай бұрын
Fantastic sir
@muhdsalman43863 ай бұрын
Dc shunt compound ke बारे में भी वीडियो बनाओ
@mdmahtabalam9253 ай бұрын
nice explained sir
@SaifulIslam-fd1wg3 ай бұрын
A Dc motor arm vot 470 and ext volt 310, 60hz if we apply in input of dc drive arm volt 400 and 310 ext, 50 hz what will happen? please let me know
@aforautomation3 ай бұрын
You have to set Input power frequency in drive parameter, drive measures frequency by itself and it will generate fault if set 50 Hz and apply 60Hz.
@aforautomation3 ай бұрын
Based on Input power frequency the SCR switching time and ramp generation signal is changed
sir 🙏, Sir i have used kinetix 5100 servo amplifier with auxiliary feedback encoder, kindly guide which parameters no is for feedback pulses.
@aforautomation4 ай бұрын
P5. 017, Aux encoder position
@aforautomation4 ай бұрын
I can share the list with you, plz share your mail id
@waheedahmad1554 ай бұрын
Can we used pid in weighing controle process
@aforautomation4 ай бұрын
PID can be used in any close loop control applications.
@sbindra36824 ай бұрын
Sir Bihar power corporation me. AC Aur DC drive diya hai . uska exam may me hai. app fir se AC and DC drive lecture le ligiye sir please
@VijayChoudhary-hc3zk4 ай бұрын
ct ke Baad star points kyu banate Hain?
@Kitty_minnie124 ай бұрын
Multispan d.c.draiv ke canection batane ki kripa kare
@aforautomation4 ай бұрын
Plz share model number or catalog number of drive
@ganeshhande79994 ай бұрын
मेरा सिंगल फेज INVT ड्राईव्ह है V FD से मोटार नदी मे अंतर 100 मीटर लंबा है पंधरा HP मोटर है कोनासा चोक लगाये कृपया बताये ?
@aforautomation4 ай бұрын
I will recommend 0.6mH, 30A Ins class-H, 3% reactor.
@aforautomation4 ай бұрын
I have uploaded a picture for the formula
@TheChinmay225 ай бұрын
Very good video.
@akashkarmakar15725 ай бұрын
Same formula maine PLC logic main use kiya, lekin jab line speed 0 MPM hota hai tab deflector roll and rewinder ka speed bhi 0 RPM ho jata hai. Tab yeah equation invalid ho jata hai. Iss calculation main kya sudhar kar sakte hai?
@aforautomation4 ай бұрын
Very nice to see this question, the value you are finding is instant Dia meter, for diameter after ramp you need to add some value to the instant Dia. This value is called change in dia meter which needs to be calculated by encoder counts feedback.
@aforautomation4 ай бұрын
If you wish I can share the Logic with you. Please let me know your email
@jayaramanneelatur91785 ай бұрын
Sir Take your fees to improve our skill.
@jayaramanneelatur91785 ай бұрын
Sir ThankQ & God Bless you
@oorkruiser5 ай бұрын
With closed loop vector control you can also accurately control motor torque above rated nameplate speed.
@aforautomation5 ай бұрын
Yes you are right, close loop vector control performance is best.
@sumits_shetty5 ай бұрын
VL - L kya hai ? 440-400? Pls explain
@adnanyounaskhan9865 ай бұрын
Sir please make a video on Direct torque control method and how can we give torque reference
@fansari44545 ай бұрын
Sir dancer roll pe video banaeye
@girishvasani83075 ай бұрын
Gurjii Aap ko Namsakar aap ko dhanya he aap ko me dil se namaskar karate hu
@aforautomation4 ай бұрын
Namaskar Bhai
@user-px5no9nv2k5 ай бұрын
Siemens g120 vfd ka profibus comunication parameter kon kon sa set korna porta hai , bata sakta hai keya sir?
@vinodbankar89425 ай бұрын
Siemens starter ke upr video banao sir aisa
@nitinmaind89675 ай бұрын
After long months How are you sir ?
@aforautomation5 ай бұрын
I am Good Nitin. How are you?
@harshvardhangaikwad35605 ай бұрын
Please sir ji Electric drives and control Subject ki all Topics ke playlists uploaded karo sir👍
@dipankardeo84795 ай бұрын
Sir make vodeo to calculate MPM .. DEFLECTOR ROLL ENCODER
@technomakealam6 ай бұрын
Nice
@technomakealam6 ай бұрын
youtube.com/@technomakealam?si=ue1HCf0zTnWdi6Hp
@sachinthakur31446 ай бұрын
DC Drive par videos banao
@ahmedbejaoui57186 ай бұрын
we should programm the Emergency stop in the ladder diagram from the automate in logo 8 or we need only to wire it thanks
@user_007596 ай бұрын
Sir, how can I connect to LS-is7 / ig5a inverter?
@dayanandagasagi84766 ай бұрын
Please explen how to work DC drive & plc in centrifugal machin in sugar plant,