Why do we connect CHWS pipe line in bottom of the cooling coil and CHWR pipe line in top of the cooling coil.. comment your answers
@shahabajmullani9553
@shahabajmullani9553 2 жыл бұрын
CHWR has warmer water than CHWS, as warmer water has lower density it will be easily go up so load on pump will automatically reduces
@shadabzeya8952
@shadabzeya8952 2 жыл бұрын
The air which remove from the cooling coil is cold and if we connect the cwrl the that air become hot. Hence reduces efficiency of Ahu. However we connect cwsl.
@freecopyrightsounds5560
@freecopyrightsounds5560 2 жыл бұрын
Because of gravity
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
Cooing coil circulting supplying up and bolwinging distbuting room cool heating retanning line outgo $$$explas shell and tubes are fitted in side the steel shell copper tubes as shown in the diagram . Cold water is circulated through the tubes by a watwr circulating pump The high pressure vapourcoming outofthe
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
Cold water culating throughthe tubesandthe vapour changesto liquied.thecollected at the bottom ofther condenser passtothe passed direactly tothe evaportor The hot waterfromthe tubes thus passtothe coolin towerand coold the coldwaterfrom the cooling tower is again circulated through the conder by water pump This continued when the water continuously circulaters rhhrough the tubes the inside becmoes coated wuth scaleand orher materials in water .. dis tey buing supppling
@khokansardar
@khokansardar Ай бұрын
Superrrr superb knowledge full video bro.
@HVACWorld
@HVACWorld Ай бұрын
Thanks 👍🏻👍🏻👍🏻
@pranitbraganza
@pranitbraganza 4 жыл бұрын
Chilled water is supplied from bottom so that the coil runs full of water, it will advace slowly filling the pipe completely....if we supply it from top, water will rush through the coil downwards and the water may not have full contact with the pipe surface leading to lesser heat exchange.
@HVACWorld
@HVACWorld 4 жыл бұрын
100 % correct.....
@irshankhan7158
@irshankhan7158 3 жыл бұрын
sahi hai bhanjee 🔥🎉
@HVACLEARNING8
@HVACLEARNING8 Жыл бұрын
Achha lga hai Sir aapka video .. Ummed krte hai aap aise hum knowledge dete rahenge taaki hum jaise new chiller tech v ek achhi job pa sake
@nirmal7061
@nirmal7061 2 жыл бұрын
Sir bohat badiya ...please vedio banate raho sir please
@shaikhfaridh4269
@shaikhfaridh4269 3 жыл бұрын
very well explained process and description of each items used.
@MohammadfirozKhan-lc1jo
@MohammadfirozKhan-lc1jo 2 ай бұрын
Very good explain sir
@hsk.123kushwaha6
@hsk.123kushwaha6 Жыл бұрын
Nice information sir
@ramsevakrajbhar3170
@ramsevakrajbhar3170 2 жыл бұрын
Ok bahut badhiya samjhae Hain aapane
@mdaafanhasan2651
@mdaafanhasan2651 4 жыл бұрын
You explained very well
@sunnymodi9393
@sunnymodi9393 2 жыл бұрын
Nice, very helpful. Upload more videos on HVAC piping system please like for Pumps - vertical & horizontal, chiller, boiler pipe connections. Thank you.
@HVACWorld
@HVACWorld 2 жыл бұрын
Thanks
@bikashbera1113
@bikashbera1113 3 жыл бұрын
very good explanation sir
@fatdubai
@fatdubai Жыл бұрын
Very informative video Thanks
@angreentachairconditioning4687
@angreentachairconditioning4687 3 жыл бұрын
Bahut pasand aayi bhai
@shabbirjaan8480
@shabbirjaan8480 9 ай бұрын
Very well explained process
@syedbasheer2299
@syedbasheer2299 9 ай бұрын
👍👍👍
@abhijitkandale458
@abhijitkandale458 3 жыл бұрын
Nicely explained
@ssraorao7565
@ssraorao7565 3 жыл бұрын
Excellent explation thank you sir
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
Vrey good exlant noy belved baiwhat is sayed bai
@mohdumar2692
@mohdumar2692 2 жыл бұрын
Good information
@satyamprajapati9064
@satyamprajapati9064 3 жыл бұрын
Nice explain
@parvejali5088
@parvejali5088 11 ай бұрын
Nice vidios 🤟👌
@mechanicalirshadirshad1092
@mechanicalirshadirshad1092 Жыл бұрын
Excellent 👌👍
@KumarD257
@KumarD257 2 жыл бұрын
Very good.
@mohammadreyaz6071
@mohammadreyaz6071 3 жыл бұрын
Awesome
@mdansaralam2287
@mdansaralam2287 3 жыл бұрын
Good sir G
@shaikhshahzad7177
@shaikhshahzad7177 2 жыл бұрын
The CHWS always be connected to the bottom side of AHU because we have to filled the pipe lines maximum by the chilled water and there is no air vapor existing during the CHW circulating. also its helps to make a proper cooling due water resist to up side and absorbed to all heats.
@HVACWorld
@HVACWorld 2 жыл бұрын
One of the greatest answer i received....
@md.shahid4305
@md.shahid4305 7 ай бұрын
Ahu unit ke supply line me drain cock kya kaam hota hai
@maroofalikhan6210
@maroofalikhan6210 Жыл бұрын
Great
@user-ug3kg3hq4u
@user-ug3kg3hq4u 10 ай бұрын
Very nice sir, pls tell me about Ahu blower working
@shamsuddinansari3001
@shamsuddinansari3001 2 жыл бұрын
Good
@mohd.ibrahimsiddiqui6585
@mohd.ibrahimsiddiqui6585 3 жыл бұрын
Very good teaching sir Why balancing valve place at return line of AHU, why not at Supply line? Please give me the answer.
@HVACWorld
@HVACWorld 3 жыл бұрын
To ensure the amount of water flow across the coil
@doanthanhbinh4308
@doanthanhbinh4308 2 жыл бұрын
Can we place balacing valve at supply water line ?? Any drawback comparing to placing at return line ?
@aadilraza5842
@aadilraza5842 Жыл бұрын
Ahu pressure gauge me inlet jiyada hoga ya outlet
@zabirhussain5582
@zabirhussain5582 3 жыл бұрын
Ahu ke bottom se child water suply hum isliye conect krte hai heat transfer jo ho wo better tarike se heat transfer ho dusra child water suply ata hai child water se air me heat transfer ho jab hamara child water ata hai to wo cooling coil se feel hote hue ata hai isliye niche se child water suply ko conect krte hai agar hum upar se conect krege to wo crevety se child water direct niche aa jyega Or wo cooling coil ki contect me jyda der nhi rah payega isliye niche se child water suply line ko niche se conect krte hai
@HVACWorld
@HVACWorld 3 жыл бұрын
Correct
@enam16
@enam16 3 жыл бұрын
How much we take average distance between fitting accessories in chws or chwr?
@GaanaShona
@GaanaShona 3 жыл бұрын
Please do one more video on 3 way valve sytem
@abdulquadir278
@abdulquadir278 3 жыл бұрын
Chilled water pipe connect from bottom because it takes time to return due to time delay the cooling efficiency is good. if we connect from top it passed very fast because of this cooling will be affected.
@jigarjidan4248
@jigarjidan4248 3 жыл бұрын
Very well explained, but I have a doubt for isolation valve, please could you explain me the working of isolation valve ??
@victorvalencia5603
@victorvalencia5603 2 жыл бұрын
function is close to make maintenence, or change any device
@ssraorao7565
@ssraorao7565 3 жыл бұрын
Sir please tell me why secondary pipe line and primary pipe line between provided bypass valve
@manojbaghel1175
@manojbaghel1175 3 жыл бұрын
Manoj Baghel present sir
@bhatuborane7761
@bhatuborane7761 3 жыл бұрын
If Balancing Valve will balance the flow, then why we incorporate PICV?
@mrlee2691
@mrlee2691 Жыл бұрын
Heat exchanger accha hone ke liye suplay in me hoti he
@roshanbharat8962
@roshanbharat8962 2 жыл бұрын
Why 3 way control valve is not shown?
@virgilionaviamos8784
@virgilionaviamos8784 6 ай бұрын
Requesting an English language.
@suershsingg7584
@suershsingg7584 3 жыл бұрын
chill water piping sply yepsu ke niche rahta h jisese maintenance me aaram rahta h
@akhilkumarpal2104
@akhilkumarpal2104 4 жыл бұрын
Sir ahu ka cfm ka 2nd videos ni aya and sir ahu k blower k barr mai videos bnae .backward and forward blower kya hota hai or kaise work krta hai plz
@HVACWorld
@HVACWorld 4 жыл бұрын
Sorry for delay friend.....CFM ka video bhut jald upload ho jayega...or AHU k blower ka video v koshish krunga dalne ki... Channel se jude rhe or v informative videos ayegi
@akhilkumarpal2104
@akhilkumarpal2104 4 жыл бұрын
Kkk i m waiting for your important videos🤔🤔🤔🤔🤔
@anwarulislam1392
@anwarulislam1392 3 жыл бұрын
Inlet and outlets pressure differences???
@usmanahmed8842
@usmanahmed8842 4 жыл бұрын
Nice video But I see arrangement with gate valve instead of butterfly valve
@HVACWorld
@HVACWorld 4 жыл бұрын
Gate valve is also an isolation valve....now butterfly valve widely used in ahu for pipe size 50mm and above
@usmanahmed8842
@usmanahmed8842 4 жыл бұрын
HVAC World right sir and thank you
@HVACWorld
@HVACWorld 4 жыл бұрын
My pleasure....new video also uploaded on cooling tower...watch for your knowledge and don't forget to share with friends
@usmanahmed8842
@usmanahmed8842 4 жыл бұрын
HVAC World sure
@abdulqayyum5413
@abdulqayyum5413 Жыл бұрын
What should be the maximum and maximum flow in picv
@mudassarnazar8862
@mudassarnazar8862 2 жыл бұрын
if we are using PICV VALVE .. what is the need of balancing valve then ? please clarify for this point that i have raised ..
@HVACWorld
@HVACWorld 2 жыл бұрын
If you are using PICV valve at AHU connection, You don't need balancing valve. PICV valve self balanced water flow and regulate flow like 2-way valve
@mudassarnazar8862
@mudassarnazar8862 2 жыл бұрын
@@HVACWorld ok thanks
@daudahmad414
@daudahmad414 2 жыл бұрын
@@HVACWorld sir as you said above that if we are using PICV then no need to install DRV but i saw in other channels they use both Valve at AHU connection so i got confused please clear this one we should use both valves or not as per international standards
@satyamprajapati9064
@satyamprajapati9064 3 жыл бұрын
Sir pid valve open karenge to kaise maloom hoga ki valve open ho gya hai kyoki usper koi indecater ya symbol wha hota nhi hai
@mdkaif1049
@mdkaif1049 4 жыл бұрын
Pressure drop propeller nhi hoga or AHU k inlet nicha is liya hota hai water flow m Kuch time laga to cooling properly ho ga isliya krte hai nicha se
@HVACWorld
@HVACWorld 4 жыл бұрын
Very good 👍
@habibarmaan8289
@habibarmaan8289 Жыл бұрын
Awsm trick boss
@iftekharamjad7674
@iftekharamjad7674 2 жыл бұрын
Inlet hamesha niche iss liye hota h q ki air lock se bachne ke liye hota h
@PradeepKumar-gd1ic
@PradeepKumar-gd1ic 4 жыл бұрын
IAQ ( INDOOR AIR QUILET) AHU STATEME KE BARE MEIN VIDEO BANAYE
@altafansari3442
@altafansari3442 Жыл бұрын
Air cooled chiller me bypass line kyun use karte hai?
@mdashrafali7368
@mdashrafali7368 4 жыл бұрын
Sir, reverse and forward movement aur uske application k bare me video bnaye
@HVACWorld
@HVACWorld 4 жыл бұрын
Reverse and forward movement of which part????...plz explain
@mdashrafali7368
@mdashrafali7368 4 жыл бұрын
@@HVACWorld Sir, I want dwtailed explanation of forward and reverse movement of blower as per the requirements and its appliction
@HVACWorld
@HVACWorld 4 жыл бұрын
@@mdashrafali7368 ok i will explained it in next video which will be upload soon
@karelalrajpal
@karelalrajpal 4 жыл бұрын
Sir can you plz 🙏give me your contact no. Jiske dwara me apse call par dowt clear kar saku Sir plz don't ignor me
@karelalrajpal
@karelalrajpal 4 жыл бұрын
Me mechanical engineer hu me pharma company me job karta h
@saleetmazhar5978
@saleetmazhar5978 2 жыл бұрын
Which liquid is preferred in thermowell
@HVACWorld
@HVACWorld 2 жыл бұрын
Mercury is ideal
@abdulmasud5990
@abdulmasud5990 Жыл бұрын
Bahi Y stanar retain line rahta sayad
@DBG01Sanju
@DBG01Sanju 3 жыл бұрын
AHU Chill water pipe line ke saat Hot water pipe line be Hoti hai jiska temperature 55 degree Celsius hota hai usske bare me koyi information hai Tu please bataye ....ussi AHu me Kay working role hota hai
@HVACWorld
@HVACWorld 3 жыл бұрын
You will get answers to your every question... kindly get the channel membership
@mdakhil2647
@mdakhil2647 3 жыл бұрын
Sir....pressure gauge me kitna pressure maintain karna hoga in aur out pipes me
@HVACWorld
@HVACWorld 3 жыл бұрын
Difference 0.5-1.0 Kg/cm2 ka hona chahiye
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
Supply 50 retand55
@moonsheikh7117
@moonsheikh7117 2 жыл бұрын
@@HVACWorld sir usne chilled water line ke supply nd return ka pressure pucha h ? Pls tell me I also want to know I have seen in psi Supply line pressure 100 psi Nd return line pressure 90 psi which means 10 psi difference I don't know in kg/cm^2
@jishilk9747
@jishilk9747 Жыл бұрын
​@@moonsheikh7117 as per ur values, pressure difference is 10psi, i.e. 0.7 bar (or kg/cm2) which is matching with values given by hvac world
@HVACWorld
@HVACWorld Жыл бұрын
Supply and return line ka pressure defined nhi hota h.... you will get pressure difference always in TDS
@omkumarsubba3967
@omkumarsubba3967 2 жыл бұрын
ok 3way velbaka sath ek video
@HVACWorld
@HVACWorld 2 жыл бұрын
Ok
@mdaakiftanweer9374
@mdaakiftanweer9374 4 жыл бұрын
Sir tho definition written mai bhi daliye
@HVACWorld
@HVACWorld 4 жыл бұрын
Ok sir g
@naushadahmed2552
@naushadahmed2552 3 жыл бұрын
Sir how to set balancing valve
@ashwadkhan9818
@ashwadkhan9818 2 жыл бұрын
Water ka pressure drop hone ke liye
@AshrafKhan-xu4wk
@AshrafKhan-xu4wk 4 жыл бұрын
sir Chiller ka inlet outlet pressure kitna hona chahiye minimum and maximum
@HVACWorld
@HVACWorld 4 жыл бұрын
Coming video me clear kr dunga...
@AshrafKhan-xu4wk
@AshrafKhan-xu4wk 4 жыл бұрын
@@HVACWorld Thank you sir
@aymankhan9001
@aymankhan9001 3 жыл бұрын
Chiller ka inlet 7 outlet 12 hota hai
@sbhosale2101
@sbhosale2101 3 жыл бұрын
@@aymankhan9001 He is taking about pressure, not temperature.
@aymankhan9001
@aymankhan9001 3 жыл бұрын
@@sbhosale2101 oo sorry by mistake I write down temperature....
@farhanalam270
@farhanalam270 3 жыл бұрын
How will be rectify that strainer is dirty...
@HVACWorld
@HVACWorld 3 жыл бұрын
By cleaning strainer....first open tha strainer remove the mesh clean it properly and re-fix it
@aymankhan9001
@aymankhan9001 3 жыл бұрын
Because that will cooling effect in the room go and check temperature thermometer and pressure gauge of ahu..the supply of water down temperature show thwn you will have to check satiner and clean cylindrical filter and fix again
@leonardobejosano7516
@leonardobejosano7516 3 жыл бұрын
Is there English explanation .
@shahrukhqureshi1841
@shahrukhqureshi1841 2 жыл бұрын
Why purge valve place child water line and why not place on child water supply line
@exploreway6935
@exploreway6935 29 күн бұрын
Air moves in updirection.. May be that's the reason
@karelalrajpal
@karelalrajpal 4 жыл бұрын
Plz
@Abhishekkumar-fc2nz
@Abhishekkumar-fc2nz 4 жыл бұрын
Chilled water pipe neeche isliye hoti hai kyuki, chilled water me moisture ( more weight) and return water pipe ka weight kam hota hai. ( less moisture ) , isliye water ka circulation ache se ho. Please reply I'm right or wrong.. I'm new, (fresher) .
@HVACWorld
@HVACWorld 4 жыл бұрын
I appreciate your effort....iske answer ka maine separate video bnaya hai...aap wo dekhe, apka doubt clear ho jayega....
@delowarhossain6615
@delowarhossain6615 3 ай бұрын
Vai kichlia niche araho?
@delowarhossain6615
@delowarhossain6615 3 ай бұрын
Sir
@mohitsharma-xe2zl
@mohitsharma-xe2zl 3 жыл бұрын
Mohit sharma Roll no 17
@aanimevideoyoutube
@aanimevideoyoutube 26 күн бұрын
Chiled Water pipe Noxhe Se Q connect Rehta Hai
@HVACWorld
@HVACWorld 25 күн бұрын
Kyu k paani upar ayega to gravity k against me ayega jisse ke ye ensure hota h k coil k andr pura paani fill ho or better heat transfer ho
@godwinjohn2639
@godwinjohn2639 Жыл бұрын
Not in English why??
@vrkalyan11
@vrkalyan11 Жыл бұрын
This connection not gives satisfactory result.Only 3 way motorise valve give proper result.
@bhatuborane7761
@bhatuborane7761 3 жыл бұрын
If Balancing Valve will balance the flow, then why we incorporate PICV?
@hayathism
@hayathism 3 жыл бұрын
My Questions also same to u We r using PICV then why required Balancing valve
115 - How to design AHU and FCU valve package
4:50
NC Engineering & Technology
Рет қаралды 2,1 М.
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 5 МЛН
لقد سرقت حلوى القطن بشكل خفي لأصنع مصاصة🤫😎
00:33
Cool Tool SHORTS Arabic
Рет қаралды 29 МЛН
Box jumping challenge, who stepped on the trap? #FunnyFamily #PartyGames
00:31
Family Games Media
Рет қаралды 20 МЛН
小蚂蚁被感动了!火影忍者 #佐助 #家庭
00:54
火影忍者一家
Рет қаралды 41 МЛН
Chilled Water Fan coil unit pipe Hook up Details or Installation Details
2:03
HVAC-R -BE PROFESSIONAL
Рет қаралды 65 М.
Chilled water AHU connection and Accessories details in Hindi
4:48
FCU & AHU - Applications of 2-Way and 3-Way Valves (HVAC SYSTEM)
12:27
HVAC SIMPLIFIED
Рет қаралды 117 М.
ceiling cassette chiller water installation
9:21
titopags tv
Рет қаралды 17 М.
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 5 МЛН