Ahu Chilled water piping conections from header line
Пікірлер: 95
@ansariferoz1768 жыл бұрын
3 way valve is used to bypass the chilled water according to the temperature set on the thermostat. suppose,temperature is seted on thermostat @24 and temperatures reched around 20 then it allow water to flow 20% from the coil and bypass the rest 80% water through the bypass line.
@ASADKHAN-xb3vn3 жыл бұрын
Very useful information Thank you so much
@areebahmad89446 жыл бұрын
Great Work Gaurav, thank you very much.
@junglee629 жыл бұрын
I appreciate your effort. Very helpful man. Thanks keep the good work going.
@salmanahd42979 жыл бұрын
Thank you my dear for such a brief Video
@EXPLORINGPIPING6 жыл бұрын
really great job sir .... nice explanation
@Irafn19 жыл бұрын
Hi Kuntal, I appreciate you for uploading such videos and I wanna add some more information here that, regarding the function of the 3-way control valve not ton maintain the flow rate inside the AHU coil but to control the flow .Based on the thermostat reading & BMS command the valve will allow some chilled water to flow through by pass line.
@kuntalgaurav0009 жыл бұрын
I agree with u... by mistake I used the wrong word "maintain" instead of "control"....:)
@Irafn19 жыл бұрын
Well done
@IrfanAhmad-zo6ni7 жыл бұрын
Assalamo alaikum brother.nicely corrected. Need to talk to you as i am having some issues.can you contact me at irfan.stress@gmail.com.hope to hear from you .
@aeroabdul19 жыл бұрын
Very Good Video which is explained very simply and practically. Thanks a lot!!!
@aameerkhan28657 жыл бұрын
Really appreciate you Gaurav
@amala-rahman45318 жыл бұрын
gr8 work bro, really useful, thanks for the effort.
@shareeftkp7 жыл бұрын
Good work Gaurav.
@hossamhamed24679 жыл бұрын
thanks to show, and i wish to add more videos with your clear explain
@afkarahemed41349 жыл бұрын
Gd one bro.i lyk it.n thnxx fr sharing sch god info.thnxxxx
@nishadquadri52189 жыл бұрын
vary nice video as well as explanation. thanks gaurav.
@samueljesus44608 жыл бұрын
excellent explanation god bless you
@areebahmad89446 жыл бұрын
Thank you very much bhai. Please make one video for cooling tower also. :)
@ranaimran50277 жыл бұрын
Excellent explain thanks bro
@khwajafaisal51611 жыл бұрын
Thank you sir, your really nice.
@sunilghorpade168211 жыл бұрын
thnx gaurav, please have more vdo in this field with p and id diagrams. once again thanx for reply.
@joenerful10 жыл бұрын
I really appreciate you sir and would like only to have an additional point to include which is the isolation of 3-way valve in case of future maintenance/replacement. I am thinking to have a threaded couplings of 2" to be connected on 2 inlets and 1 outlet of the the 3-way valve...I would appreciate for any feedback.
@mohammadqaderqader24257 жыл бұрын
I would suggest couple of more items as well. first add 2 more automatic air release valve at the intake and discharge side of coil to purge air from coil and prevent coil from air trapping. b - always add a drain valve at the bottom of your strainer cap. c - make the drain pipe longer at least 1ft to collect drain from the system with drain valve for isolation. good luck and keep up the good work.
@incrediblethings116 жыл бұрын
Thank You So Much Gaurav..
@gdf6066 жыл бұрын
Good explanation sir
@Luckified10 жыл бұрын
I love ur Accent... Hahaha
@hangoverpubg87009 жыл бұрын
Gud work Thanx bro
@masterchef66947 жыл бұрын
thank you very much gaurav
@mohammedimtiyazahmed655011 жыл бұрын
Thanks Your Videos Sir
@suhailshams79618 жыл бұрын
informative..thank you
@imtiyazmod88039 жыл бұрын
Thanks gaurav bhai your video tutorial is great.can you please help me by uploading the video of chiller connection to the pumps and to the Fcu. If you can please it will be of great help.
@shamsheralam88623 жыл бұрын
Thanks for the details vedioes, very useful. I want to know how the welding joint is tested for chiller piping is it by MT ?
@kyawlay233610 жыл бұрын
Nice explanation
@rahulpatekar691210 жыл бұрын
thanks ......... good
@gouse967 жыл бұрын
Good explanation
@sakthivel.d15417 жыл бұрын
Hi kuntal thank you I need how cleaning activity in ahu pipe line and i need what using in chemical flushing .
@hhharoon310 жыл бұрын
How about two water inlet and two water outlets , where to put the reducer at the end of the AHU or when dividing the pipe by using tee there ??
@masterchef66947 жыл бұрын
which make double regulator valve are you using?
@hafeezrahman72259 жыл бұрын
Could you please tell me where 3 way valve we can use?? why you have preferred 2 way in this connection (in video)
@mdrustam35546 жыл бұрын
good knowledge video
@akberkhan888011 жыл бұрын
informative video. thanks
@cabuenasnelson0111 жыл бұрын
thanks your vidoes
@IrfanAhmad-zo6ni7 жыл бұрын
nice vid
@istiyaqueahmad587811 жыл бұрын
Thank You
@mohammadqaderqader24257 жыл бұрын
My friend couple of issues with your installation( a-I see the 3way valve is installed and there is not way to change it. since it is a 2in valve having a union is looks like necessary for maintenance works. b - You used 3in gate valve.. it is better to use butterfly valve since it takes less space.d-you do not need 2 reducers at the return side before 3way valve and cooling coil since they same size 2inch.
@ahmedabdelsalam151910 жыл бұрын
Thank you
@antojose90398 жыл бұрын
This 3way(mixing) valve or 3way(diverting) valve?
@peaceisthebestthebestispea27446 жыл бұрын
What is the use or function of bypass valve from supply to return?
@dukebmxrider9 жыл бұрын
thank you for your informative video we just replaced the gate valve for the supply from 17 to 22.. but after three gate valve fitings due to factory defect it is ok now except the return gate valve is leaking now since it is 14years old and only now has been open it is dripping 1 drop per five seconds.. one of our outlets wich is rented has been complaining about losing customers during the installation of the supply gate valve so its a very hard for me to suggest to chairman(my father) that we need to replace the return gate valve..we operate a hotel in bahrain.. will the gate valve hold up for one year before bursting? it is cold season now here but we still need aircondition for our outlets
@valaypatel74039 жыл бұрын
***** try econosto gate valve. and what is current gate valve please write here .
@sagarsuryavanshi23933 жыл бұрын
👍👍👍
@shadabshaikh39308 жыл бұрын
Hi! why isn't there a by-pass for the modulating valve?
@sarathjames86539 жыл бұрын
Friend, there is many way to connect an ahu regards to its design...plzz teach them the most best way...if not possible the most commonly used way..
@derlabeso6007 Жыл бұрын
Great
@nevinjohn371611 жыл бұрын
How about regulating pressure in the pipes? Suppose the chillers are located in the terrace, and this AHU is in the basement. So the pressure (water height) acting on the AHU coil would be very high! What can be done in such as case??
@masterchef66947 жыл бұрын
why have you used gate valve for isolation....why not butterfly valve? thanks again
@varietytubesbd83254 жыл бұрын
thanks sir
@fazilm87 жыл бұрын
Bhai, y there. is a need of iv valve on return while we are having drv .how will you.do flushing with this bypass
@sunilghorpade168211 жыл бұрын
gaurav kuntal ji, i agreed to you pipe line connections. but is there any insulation required for pipe lines please explain
@lujensacel878511 жыл бұрын
Can u give also about the pipe connection of AHU with heat recovery?
@kuntalgaurav00011 жыл бұрын
offcourse insulation is required in every chilled water line.... normally we use fibre glass or glasswool insulation.
@habeebrk10 жыл бұрын
very nice..
@walidabdul36811 жыл бұрын
engineer regarding with chemical treatment when all pipe is already finished work why? that time i put chemical is the all sytem water in pipe line is very hot do you have any idea of this.....
@nishanthkumarsk69709 жыл бұрын
ello sir, i am working as an site engineer mechanical(hvac).in my system we are used 2 way motorized valve in return line.may i knw what is the diffrence btw the function of 3way and 2 way.in 2 way it is need to require bypass
@muhammedshafy83079 жыл бұрын
Can you explain the difference between a BALANCING VALVE & DOUBLE REGULATING VALVE
@valaypatel74039 жыл бұрын
Muhammed Shafy ing Valve so you can say that , you can adjust the flow through the balancing valve and usually in ahu & Fahu , DPCV is used for regulate the pressure.
@granerobiju11 жыл бұрын
what is use of regulating valve
@shamsheralam88623 жыл бұрын
Kindly me same type of vedioes on chiller pump
@mohamedkadabe180510 жыл бұрын
good
@zeehanable11 жыл бұрын
hello can u please explain me what is the function of strainer
@rahulsaxena7955 жыл бұрын
FLEXIBLE IS FOR VIBRATION ALSO
@sarathjames86539 жыл бұрын
On flow...
@rehansuddu10 жыл бұрын
may i get chilar connection detail as u hv given abt AHU, sir ,i wanna knw whole connection ,chillar to ahu and water cooler,,and a mentaion valve and its function also
@rahulsaxena7955 жыл бұрын
YOU SHOULD INSTALL UNIONS FOR 3 WAY VALVE
@kuntalgaurav00011 жыл бұрын
kindly watch d vdo again i already mentioned its function.
@abuayesha42619 жыл бұрын
York chilled water ahu not cooling what is possible reason
@kuntalgaurav00011 жыл бұрын
first of all let me tell u that chilled water system is always designed so that its pressure never exceeds the working pressure of a system, means CHW pumps are selected according to that....... in case.... according to site conditions u r getting more pressure in CHW line then u can use PRV to reduce pressure..... normally u wont find it.
@nishanthkumarsk69709 жыл бұрын
hello sir, i am working as an site engineer mechanical(hvac).in my system we are used 2 way motorized valve in return line.may i knw what is the diffrence btw the function of 2way and 2 way.in 2 way it is need to require bypass
@Irafn19 жыл бұрын
Hi Nishan, There are normally two types of chilled water system in the industry one is variable flow system where we use 2-way control valves and other one is constant flow system where we use 3-way control valve.
@sarathjames86539 жыл бұрын
Incase of three way valve there is no suppose to be a cintrol....
@Qurbanalimalik9 жыл бұрын
halloo bahi ap ne by pass ma gate valve kyu nai lagaya plz explain thank you..
@mdshafi88809 жыл бұрын
Thanks ihave one ahu is problem my ahu is in side coil is not cooling inlite water is coming and going but coil is not coling pls advice
@mbalajieee9 жыл бұрын
clean the filter
@valaypatel74039 жыл бұрын
md shafi checek the stainer ..please clean it. , check water temp . and so many other points are there
@Engrmarif11 жыл бұрын
The video is very informative sir...thnx a bunch...can u plz upload a video for AHU conection with ducts also? And plz write to me your email adres also if u don't mind.....thnx again!
@Zinukimasti6 жыл бұрын
where is air vent
@mohammedrahman33387 жыл бұрын
fcu fittings conection
@sankarrama84305 жыл бұрын
Plz speak to Hindi language sir
@rahulsaxena7955 жыл бұрын
THIS GUY DONT KNOW TECH DETAILS PROPERLY 2 1/2 AND ABOVE WILL HAVE FLANGE CONNECTION....AND IN THIS HOOKUP THERE IS NO DIELECTRIC FLANGE....