DSC PowerSeries Neo Alarm System Wiring Instructions - How you can be successful

  Рет қаралды 121,422

Alarm System Store

Alarm System Store

Күн бұрын

Пікірлер: 50
@jeradcampbell4359
@jeradcampbell4359 6 күн бұрын
Tell me why I did a certification class in this, but the KZbin video taught me more than the class itself
@javedbarakat2577
@javedbarakat2577 4 ай бұрын
Dude. Thank you so much. A client with so much money requested I get an alarm system for him.. truth be told I'm a networking guy.. CCTV.. access control.. servers.. switches..routers... He purchased this exact brand and detectors!! You just made me so much money haha! Thank you very much, dude. I was nervous about it but I have a very good damn understanding of this setup now. You are a legend! Hope you are doing well, cheers.
@1forthefacts254
@1forthefacts254 3 жыл бұрын
Really good
@MRrwmac
@MRrwmac 6 жыл бұрын
Jason obviously has a lot of experience in the field installing systems. He did a great job explaining and demonstrating the connections. Unfortunately the camera was upside down in half of the video. Hopefully his cold has gone away also - haha. Thank you Jason!
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
Thanks for watching. I'm afraid the upside down camera was our video editor's doing lol.
@andybowman9697
@andybowman9697 6 жыл бұрын
Jason is very knowledgeable and was a great asset to us. Unfortunately he's had to leave us for a new employment opportunity. He is certainly missed.
@MRrwmac
@MRrwmac 6 жыл бұрын
Andy Bowman Awwww. It seems every time I finally find someone that is extremely knowledgeable about a subject I need help with, they have moved on. Well, I can only hope he is happy with the new opportunity! Thank you very much for your reply Andy!
@contractorvegas5384
@contractorvegas5384 3 жыл бұрын
What did you do with the smoke detectors where do those tie into a burglar system not on fire system? I mean I know it will send an alarm signal if you put it to a zone....but the tamper switch would send a trouble and not an alarm signal, does it have to be programed differently? not a lot of burglar under my belt....tnx
@cctvgaurav
@cctvgaurav 2 жыл бұрын
greatjob. keep it up. please make video about programming all device.
@electropalsceo
@electropalsceo 3 жыл бұрын
great job -thank you
@rickturske5767
@rickturske5767 4 жыл бұрын
I have replaced several panels with 2GIG takeover modules and every panel I've worked in they have the EOL resistor at the panel. I have wondered about this for quite a while and this video confirms that the other company doesn't know what they are doing. I'm assuming they only put the resistor in at all because they don't know how to program the panel without using the resistor and hence the zone doesn't work properly without the resistor. Obviously the resistor isn't doing anything for them.
@frankbear6354
@frankbear6354 2 жыл бұрын
In the Red/Black/Yellow/Green group, i have 2 keypads and 4 extension modules. ITs difficult to try and get 4 wires all connected in one color. Can i crimp them all together and just have 1 wire going into these slots? does that make any difference?
@sandrasemente
@sandrasemente 4 жыл бұрын
Hello, I have a DSC pk5500 and it has a low battery alarm. My question is: the only battery he has is the black one UP7-12S, 12V-7Ah? I can't get it off the wall, so I don't think it takes other kind of batteries. Thanks a lot for the help.
@fxallo1
@fxallo1 3 жыл бұрын
you can also put 12v4a battery, you need to calculate the power consumption. If you have many motion, smoke detector or 4 wire device, you need to put 12v7a, if you have only 1 keypad, one panel and wireless device a 12v4A can do the job. The only difference is how much time system gonna work during power outage.
@noelr7988
@noelr7988 Жыл бұрын
Which model would you recommend to replace a pc1616 ua503 v4.6? Mine got hit by lightning.
@AlarmSystemStore
@AlarmSystemStore Жыл бұрын
The Neo 2016 is the modern = to your 1616. See here: www.alarmsystemstore.com/products/dsc-powerseries-neo-hs2016nkcp01-board-cabinet Be advised though, your 1616 keypads, modules and wireless will not work on the newer platform.
@noelr7988
@noelr7988 Жыл бұрын
Thank you. I appreciate it. Do I need to change keypads and sensors as well? The old ones still give continuity back to the board. It's just that power is not making it past the initial contact.
@noelr7988
@noelr7988 Жыл бұрын
Also, is it possible to link a wireless motion sensor to the 2016 model?
@AlarmSystemStore
@AlarmSystemStore Жыл бұрын
@@noelr7988 If you have a Host 9 wireless transceiver and compatible motion detector, yes. This is all the wireless products for Neo panels: www.alarmsystemstore.com/collections/dsc-power-series-neo-wireless-sensors
@noelr7988
@noelr7988 Жыл бұрын
I just purchased my hs2016 system from your online store. Will my current keypad RFK5501-433 work with the hs2016?
@alanhill3968
@alanhill3968 4 жыл бұрын
Hi. I need help wiring a ventcroft Bellbox to my DSC panel the Bellbox terminal are stab - hold off +. hold of - Run - Trg - Can anyone advise which terminals these go to on the DSC panel Thank you
@gloproglowingcups4795
@gloproglowingcups4795 Жыл бұрын
Do you wire a wireless transceiver module into the corbus?
@AlarmSystemStore
@AlarmSystemStore Жыл бұрын
Yes you do
@gloproglowingcups4795
@gloproglowingcups4795 Жыл бұрын
@@AlarmSystemStore Awesome thanks. I also keep getting tamper switch indicators on the keypad. I went around to make sure they are all depressed and ok. I can’t get to clear. Is there some kind of bypass or cheat to tell the system to ignore the switches. Thanks
@AlarmSystemStore
@AlarmSystemStore Жыл бұрын
@@gloproglowingcups4795 I am not in tech support, but I am fairly certain you can turn of keypad tampers in keypad programming.
@drewmurphy2796
@drewmurphy2796 2 жыл бұрын
Does dsc still make hardwired systems or is everything wireless now?
@AlarmSystemStore
@AlarmSystemStore 2 жыл бұрын
DSC's biggest lines are hardwired hybrids actually. They make less total wireless systems than they did say 5 years ago. See here for the latest hardwired / hybrid line. www.alarmsystemstore.com/collections/dsc-powerseries-neo
@teckiful
@teckiful 3 жыл бұрын
If you have 6 expander boards, does all 6 parallel on the main board??
@AlarmSystemStore
@AlarmSystemStore 3 жыл бұрын
Yes all are connected to the same keybus. Doesn't have to go directly back to the panel though, could be tapped at a keypad for example if need be.
@vidovictatarski
@vidovictatarski 4 жыл бұрын
hello, sorry for my english , I have a question ,in a situation when you have more than 1 motion sensor how you connect a tamper switch, paradox alarm system have nc with eol with tamper & wire fault recognition, where they do that with 2 1K ohm resistors conected in series, I would like to do similar thing with dsc
@fxallo1
@fxallo1 3 жыл бұрын
you can connect with 2x 5.6k like paradox and you go in section 013 option 2 for doube eol
@MAbhy-ml9cs
@MAbhy-ml9cs 4 жыл бұрын
sorry sir I want to ask in my serine there are six cables please help wiring the panel and whether I have to use a resistor
@eMinatti
@eMinatti 4 жыл бұрын
Pick 1 black and 1 red from the siren. Splice it to the black and red wire that's going to your panel. No need for a resister.
@robh9020
@robh9020 2 жыл бұрын
So the resistors that come with the kit are not necessary?
@andybowman9697
@andybowman9697 2 жыл бұрын
That's a matter of opinion. I recommend using them, but yes you can tell the system not to look for them if you don't want to, other than on smokes.
@danladikanyio390
@danladikanyio390 4 жыл бұрын
quite explicit but am more interested in the wireless configurations
@ashok1949
@ashok1949 3 жыл бұрын
Jason - how to take a zone off your system permanently. Thanks
@Meza201
@Meza201 5 жыл бұрын
Helpful vid but did how did no-one notice the long explanation of the terminals was filmed upside down!
@electropalsceo
@electropalsceo 3 жыл бұрын
Jason if you need a job and in the Chicago land area - let me know
@Murdxr3
@Murdxr3 5 ай бұрын
Just for laughs, you put the 4 wire smoke, yellow wire, in the comm instead of the zone terminal😅.
@ionutvasilache6679
@ionutvasilache6679 4 жыл бұрын
How to wire 3 Panic buttons in series with deol?
@fxallo1
@fxallo1 3 жыл бұрын
DEOL is more effective with one device per zone but its possible with multiple device,put one resistor in paralel with each nc/c contact and put resistor in the last device in serie between the contact and the wire
@danielreyes5972
@danielreyes5972 2 жыл бұрын
can yall xfinity panel
@sovannakdos7856
@sovannakdos7856 Жыл бұрын
How to change 1234 to a new user code?
@MRrwmac
@MRrwmac 6 жыл бұрын
Jason, did you get a haircut or just tie it up in back!
@AlarmSystemStore
@AlarmSystemStore 6 жыл бұрын
He tied it up in this one
@andybowman9697
@andybowman9697 6 жыл бұрын
Ha, he had it pulled back here, but he did end up cutting it for a new job he went to recently. Not sure if he'll see your comment or not so I thought I'd answer.
@daylonnorris765
@daylonnorris765 3 жыл бұрын
Upside down and out of focus
Alarm System Store - All about resistors
18:19
Alarm System Store
Рет қаралды 134 М.
Family Love #funny #sigma
00:16
CRAZY GREAPA
Рет қаралды 32 МЛН
Motorbike Smashes Into Porsche! 😱
00:15
Caters Clips
Рет қаралды 15 МЛН
Perfect Pitch Challenge? Easy! 🎤😎| Free Fire Official
00:13
Garena Free Fire Global
Рет қаралды 53 МЛН
Elza love to eat chiken🍗⚡ #dog #pets
00:17
ElzaDog
Рет қаралды 18 МЛН
DSC NEO Installation - Step by Step
17:20
The Automation Guy
Рет қаралды 495 М.
Alarm System Store Tech Video - DSC Power Series Basic Wiring
18:32
Alarm System Store
Рет қаралды 178 М.
Series and Parallel Wiring With Alarm Systems Explained
25:59
Alarm System Store
Рет қаралды 10 М.
Adding an External Communicator to a DSC PowerSeries NEO
14:13
Alarm Grid
Рет қаралды 33 М.
Family Love #funny #sigma
00:16
CRAZY GREAPA
Рет қаралды 32 МЛН