Best tutorial on protection. Thanks for sharing your valuable knowledge for free and for people like us who cannot afford premium subscription to some online educators. You are one of the best teachers I have learnt from as far as Electrical Engg. is concerned. 👍🙏
@electricaltechnologyandind53354 жыл бұрын
Thabks a lot....
@krnair22556 ай бұрын
Aptly explained. Hope this the tutorial will aid students as well as beginners of profession a handy presentation. Thanks a lot.
@surendrakverma5552 жыл бұрын
Very good. Thanks 🙏🙏🙏🙏🙏🙏🙏
@DryPepperEntertainment Жыл бұрын
Superb explanation thank you soo much
@zoro4zena4 жыл бұрын
Best content utube ❤️
@awadmohamedahmed48392 жыл бұрын
Nice Explanation, thank you so much
@abhisheksingh-cv7iq3 жыл бұрын
Very nice explanation 👌
@rameshnabde15824 жыл бұрын
Very good & informative video
@prabhakarangovindaraj92385 жыл бұрын
Hatts off sir,👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍
@PramodKumar-zl4gq2 жыл бұрын
Excellent explanation sir
@prafulhalmare4 жыл бұрын
Great video Ring mail system is awaited
@varimas4 жыл бұрын
11:00 Sir, is it allowed for a double bus scheme system to skip the bus coupler Theoritically, i want to isolate bus 1 for maintenance. Convention is: 1. Close bus coupler 2. close both bypass isolator 3. Open bus 1 isolators bus side 4. Open bus coupler Can i do it like this? 1. Close incomer bypass isolator (Negligible current, bus 2 energize, same potential as bus 1) 2. Close outgoing bypass isolator (Same potential as bus 1) 3. Open bus 1 isolators bus side If i skip the bus coupler using these step what are the consequence?
@electricaltechnologyandind53354 жыл бұрын
No, then all the incoming and outgoing feeders breaker will be bypassed. You need to close the bus coupler first to bring both the buses at same potential. Follow convention an standard operating procedures. Do not improvise in ehv system, that can be fatal. Think multiple time properly.
@varimas4 жыл бұрын
@@electricaltechnologyandind5335 Sir, Thank you for the safety concern/instruction and speedy reply I am nowhere near any ehv. I am working on a school project computer program on bus operations. All theoretical. I have allowed isolator to operate on no load condition except if there exist a parallel path of equal potential or negligible current. So far my incorrect steps allowed the bus to operate without consequences and the incoming and outgoing feeders where not bypassed. I have to find a way to include these restriction. Sir what program did you use to show us the operation of isolators and breakers in another video? Again thank you, this video gave me an understanding on how bus scheme operation works.
@electricaltechnologyandind53354 жыл бұрын
Remember two thing regarding isolator operation. 1 no current change 2. No voltage change. Now what you said earlier will let you operate the isolators but that will eleminate all circuit breakers of the feeders. And also the by pass isolators are interlocked with other bypass isolator. So you can close only one by pass isolator at a time.
@varimas4 жыл бұрын
@@electricaltechnologyandind5335 Sir, Thank you for your insights and suggestions. What you mean by eliminate all feeder circuit breakers is that the circuit breakers will automatically open? I realized I was missing the interlock restriction. By putting an interlocking condition such as if a bus isolator is closed, the other bus isolator can only be operated when the busbar coupler is closed, i avoided comitting my hazardous incorrect steps.
@kiransaikia12522 жыл бұрын
Necely described tutorial. Please add voltage levels for eachv scheme.
@xnasna61513 жыл бұрын
អគុណបង😍
@Durga1894 жыл бұрын
Nice explanation. Please do a video on breaker rating calculation
@debarpanchanda90383 жыл бұрын
First of thanks a lot for the video sir.. 🙏🙏 I just wanted to know that, in one n half breaker i-type scheme for every feeder there is one dedicated isolator is mentioned, but in case of feeder fault or maintenance both the Circuit Breaker as well as the isolator will open, which is placed either side of the feeder, then why there is one extra dedicated isolator for the feeder...? Expecting a reply from your side. Thanks in advance sir. 🙏🙏🙏🙏
@electricaltechnologyandind53353 жыл бұрын
So that the feeder can be connected in either bus. It can not be explained over comment. Iwill make vdo
@debarpanchanda90383 жыл бұрын
@@electricaltechnologyandind5335 plz sir make one video on it..🙏🙏
@safnaskariapper75054 жыл бұрын
superb!
@sanjaykumarsharma34523 жыл бұрын
Great!
@sohambhattacharyya11264 жыл бұрын
Very good sir, Sir just define me and provide me the purpose of bus bar, main bus transfer bus etc
@madhukarshukla25644 жыл бұрын
I think protection will be shifted before charging the bus coupler breaker.... Also a scheme come in which when u close last isolator... It will not possible before transfer tht protection
@electricaltechnologyandind53354 жыл бұрын
The protection changes as per the isolators are switched.
@shashankkumar77704 жыл бұрын
We have single busbbar scheme at switchyard,single busbar with sectionaliser in indoor switchyard,double busbar scheme at alternator site..
@electricaltechnologyandind53354 жыл бұрын
Indoor switchyard!!!!!!! Is it GIS or the PASS which is also called hybrid substation.
@shashankkumar77704 жыл бұрын
@@electricaltechnologyandind5335 yes sir gis
@electricaltechnologyandind53354 жыл бұрын
Yard is refer to outdoor system. Switchyard will refer outdoor assembly and interconnection of switching equipments. GIS is a very reliable system. But expensive. Which plant you are referring??
@shashankkumar77704 жыл бұрын
@@electricaltechnologyandind5335 sorry sir instead of swithgear I wrote switchyard mistaken
@EberFarmo7 ай бұрын
Hi. Are you sure about your explanation for close the disconnector???? 9:00 to 10:00 You can not close the disconnector just because the voltage of both side is equal.
@electricaltechnologyandind53357 ай бұрын
Possible. Isolator can be closed if there is no change in current or voltage.
@EberFarmo7 ай бұрын
but you did not say that in video. Please check again your description about the priority of disconnector and circuit breaker. You said before opening the outgoing CB , you could close the disconnectir. Even you said , first close the coupler CB and after that close the bypass disconnector . It is completely wrong and impossible
@anwarullakhayoom78632 жыл бұрын
Need more clarification on Earth switches used for isolators.
@thinkseeeatthroughvickus45554 жыл бұрын
the switch gears with its cubicle consist of its portion of Bus bars. So except for single bus bar scheme & single bus bar scheme with sectionalyzer how do we employ other bus bar schemes, as we need to connect one breakers to more than one bus?
@electricaltechnologyandind53354 жыл бұрын
No other bus bar schemes are available either at outdoor i.e. switchyard or in gis(gas insulated switchgear). Normal pcc panel or switchboard has one bus with bus sectionaliser known as bus coupler
@Rajram8103 жыл бұрын
Nice
@satyarout93775 жыл бұрын
Sir can u make a video in switchyard protection scheme
@electricaltechnologyandind53355 жыл бұрын
there is nothing as such switchyard Protection. switchyard is basically high voltage feeder and bus bar system. so there Protections shall be just like the feeders like transformer feeder, incomer feeder , line feeder etc. only thing you have to remember if the switchyard voltage is 220kv or higher then bus bar differential protection is must. and for switchyard having more than one bus, there shall be Protection switching scheme. suppose you are transferring an incomer to transfer bus for the incomer breaker maintenance, then all the incomer Protection shall be switched to bus coupler.
@thinkseeeatthroughvickus45554 жыл бұрын
Sir, can you do a video on equipment voltage selection. ie, at what power rating equipment like motor should be LV, MV,HV... when we should go for LV, MV , HV substations... what is max available transformers, its KA ratings.
@sandyroyalsandeep61374 жыл бұрын
In double bus scheme your closing the buscoupler that time both bus are charged how your going to take maintenance for bus section 1..?is it compulsory to close the bus coupler..?No
@electricaltechnologyandind53354 жыл бұрын
After closing of bus coupler both the buses are charged.. now you switch over each feeder from say bus 2 to bus 2. Now your bus 2 is free. Open the bus coupler. Your bus 1 is de energized
@sandyroyalsandeep61374 жыл бұрын
@@electricaltechnologyandind5335 atlast we should open the buscoupler then only bus 1 is de energised thnk for your valuable information,kindly do a vedio on CT switching relay how it will work ..?
@godforbidden62064 жыл бұрын
in your opinion which scheme is the most optimized one??
@electricaltechnologyandind53354 жыл бұрын
One main one reserve cum transfer.
@godforbidden62064 жыл бұрын
Can you please elaborate?
@delosmark185 жыл бұрын
Hi sir, can u please discuss sizing of equipment/element in the substation?
@electricaltechnologyandind53355 жыл бұрын
Okay i will make video on that.....
@delosmark185 жыл бұрын
@@electricaltechnologyandind5335 thank you very much.