Annual fire sprinkler inspection

  Рет қаралды 2,984

Joy Cool

Joy Cool

Күн бұрын

Annual fire sprinkler inspection

Пікірлер: 32
@tmklo12
@tmklo12 Жыл бұрын
Great video!! Keep them coming
@JoyCool1
@JoyCool1 Жыл бұрын
Thanks! Will do tmklo!
@ChrisTopher284765490
@ChrisTopher284765490 Жыл бұрын
Happy Holidays to you Jim ! Good Ole Silent Knight Panels
@JoyCool1
@JoyCool1 Жыл бұрын
I love easy alarm panels! These things are a pain in the butt to reset sometimes! Thanks for your nice comments Chris Topher.
@charlesworrell5946
@charlesworrell5946 4 ай бұрын
Great job
@JoyCool1
@JoyCool1 4 ай бұрын
Well, thank you. I always appreciate a good job said to me. And I always want to thank you for watching. Thank you for that. Nice comment also. Stay strong and healthy. Bye-bye.
@ronfranz7578
@ronfranz7578 4 ай бұрын
I never liked the fact that the ITV is on the riser manifold. Although its accepted means of testing some jurisdictions still want them on end of the line for a proper flush. If the system is ever drained and recharged you will also have trapped air. During an inspection it may also be possible to disable the alarms and still have the panel annunciate properly. If there are multiple risers, each flow switch should have its own zone as well as each tamper switch. If they don't, that's usually known as the cheap bid. If there is an adequate jockey pump, some occasions you can perform n inspection with the pump off. However if there is only an annual inspection the fire pump get flow capacity tested by actually flowing water out hoses and checking that it meets its design capacity under peak loads. Additionally the fire pump (electric) shall be churn tested for 10 Min on a monthly basis, Diesel Pumps- Weekly- 30 min. Sorry for rambling on but in this business you have to CYA because most building owners don't want to spend money on something they cant see.
@JoyCool1
@JoyCool1 4 ай бұрын
You are so right about the inspectors test valve. I always like to bleed the air out myself. Your comments had a lot of great information and you seem like you know what you’re doing. It’s always nice to have people give good feedback like you did in this comment. I do appreciate and I do learn from all of those old timers that really know what they’re doing, I’m still learning every day or try to. Thank you again for watching and thank you again for that. Nice comment and very information or should I say very informational comment thank you and stay strong and healthy. Bye-bye.
@Torrque
@Torrque Жыл бұрын
After slowly/carefully recharging a drained system, why would the flow switch and mechanical bell continue to sound the alarm with a steady stream of water continuing to flow from that alarm drain line? Could the alarm valve flapper have failed to seat again?
@JoyCool1
@JoyCool1 Жыл бұрын
That sounds right.
@tmklo12
@tmklo12 Жыл бұрын
Jim what do you do if the main drain valve is so old and corroded and it like like it will snap or leak?
@JoyCool1
@JoyCool1 Жыл бұрын
I would only change it if it was leaking. I have seen some ugly valves that work just fine. Save your money Tom Maheras.
@Acee72
@Acee72 8 ай бұрын
Hi Jim, do you always have to ring the panel during annual inspections? I'm new so I need to learn this. An inspector is trying to initiate an annual inspection at our property but we have tenants and the date he scheduled is near Christmas 😬
@JoyCool1
@JoyCool1 8 ай бұрын
Yes you do. You just need to make sure that you get a signal to your alarm panel. Sometimes you can disconnect the strobes and bells from going off. If you have an electrician disconnect, the strobes or you’ll have to notify everybody that there will be going off for a few minutes. But that’s part of the inspection is to make sure that the alarm panel receives a signal from the switch. Thank you for watching. Thank you for your nice comments. Good luck. Merry Christmas and happy new year. Stay strong and healthy. Bye-bye.
@Acee72
@Acee72 8 ай бұрын
@@JoyCool1 also, there's a flow switch that isn't connected to the fire alarm panel, does the fire alarm company who services the panel have to be the one to connect it? Or can an electrician from the management company who services our property do it?
@JoyCool1
@JoyCool1 8 ай бұрын
No, the Alarm Co. does not have to be involved. Anybody that knows how to do electrical work can look it up. There’s a lot of KZbin videos on the wiring on how to hook up a flow switch. I do believe? Do not wire a lot of flow switches. I leave that up to the electricians. But I’ve done it a couple times. It’s not that hard. Good luck again. I kind of wonder why the flow switch wasn’t hooked up? Maybe it was getting false alarms? Anyway, have a good day. Stay strong and healthy. Bye-bye..
@Acee72
@Acee72 8 ай бұрын
@@JoyCool1 there's a problem with the water flow switch wiring and the vendor we hired fixed the wires, however they didn't take care of connecting it to the alarm panel and told us that the fire alarm panel company has to do it because it is not their panel (vendor who fixed the wires is also a fire alarm company) there were no alarms/signal upon annual inspection, that's why we failed. And we were just recently informed that it is not connected to the panel
@techno4evaa
@techno4evaa 3 ай бұрын
you do not have to sound the alarms during any sprinkler inspection but you must sound the alarms during every annual alarm inspection.
@myworldofsports1376
@myworldofsports1376 Жыл бұрын
Technically you can’t do a proper annual by yourself. You can’t be in multiple places @ once
@JoyCool1
@JoyCool1 Жыл бұрын
Thank you for the information. I will pass that on to my boss and let him know. Thank you for watching and thank you for your nice comments. Is there somewhere in there book that says you can not have one person do an annual inspection? That’s new to me. Thanks for the info again and thank you for watching!
@fF-jb4gs
@fF-jb4gs 4 ай бұрын
Can't do it on your own if running diesel engine iirc
@techno4evaa
@techno4evaa 3 ай бұрын
you can do a proper annual by yourself that’s nonsense
@fF-jb4gs
@fF-jb4gs 3 ай бұрын
@@techno4evaa you can't leave a diesel pump running and go around doing bell , flow testing by yourself
@jimgardner6018
@jimgardner6018 Жыл бұрын
Where’s the bell sign lol
@JoyCool1
@JoyCool1 Жыл бұрын
I will have to add this to my "to do" list Jim Gardner ;-p
@naruii5160
@naruii5160 4 ай бұрын
when we do annuals we usually have an alarm guy to disable everything and he does his inspection. if we’re doing a quarterly inspection we’ll be by ourselves so we just disable the panel ourselves, we do not want the customer to be upset.
@JoyCool1
@JoyCool1 4 ай бұрын
That is a great idea. I wish we would schedule our inspections along with the Alarm guys also. Then I could see what they mess with and I could probably learn some things and they can learn some things from me? I don’t know? That makes too much sense and we don’t do stuff like that anymore. I mean stuff that makes sense. Thank you again for watching. Thank you for your nice comments. Stay strong and healthy. Bye-bye.
@techno4evaa
@techno4evaa 3 ай бұрын
here at my company every inspector is required to do alarm, sprinkler and backflow inspections. that way you can send 1 tech to every site and get it all done in 1 stop. also you could just learn to disable alarms it’s not hard at all.
@rnriggs12
@rnriggs12 8 ай бұрын
Shouldnt the pump be running for your static and residual flow from main drain? Also you can disable the horn strobes on the panel typically.
@JoyCool1
@JoyCool1 8 ай бұрын
You make some good points. I will have to check into that. I know that we do not like to have that pump running. Unless it’s a test. And it is an annual inspection test? Thank you for your nice comment. Thank you for watching. Stay strong and healthy. Bye-bye.
@jj13jh
@jj13jh Жыл бұрын
How do you a pump run
@JoyCool1
@JoyCool1 Жыл бұрын
If you don’t know how to run a pump, you should not be running it. Somebody that knows what they’re doing should show you on site. Maybe you can find a video on KZbin. But basically you just relieve the pressure and the pump will automatically start. Then shut it off after 30 minutes if it’s a diesel pump. If it’s an electric pump you run it for 10 minutes once a month. Diesel pump gets tested once a week. Thanks for watching. And thank you for your nice comments.
5 year fire sprinkler inspection
20:02
Joy Cool
Рет қаралды 12 М.
Wet Sprinkler Inspection
1:22
Silco Fire & Security
Рет қаралды 6 М.
小丑在游泳池做什么#short #angel #clown
00:13
Super Beauty team
Рет қаралды 34 МЛН
1ОШБ Да Вінчі навчання
00:14
AIRSOFT BALAN
Рет қаралды 6 МЛН
ITM Double Interlock Preaction System
5:49
Northern Illinois Fire Sprinkler Advisory Board
Рет қаралды 60 М.
Sprinkler Room Inspection
6:18
CCPIA
Рет қаралды 2,4 М.
Oxford Mathematician DESTROYS Atheism In Less Than 15 Minutes (BRILLIANT!)
15:43
Central plant Fire alarm testing. Utility building for new elementary and middle school!
15:22
Why Millions of Smoke Alarms Can’t Catch Modern Fires🔥
16:29
Testing Painted Fire Sprinklers with Real Fire
6:39
FireAlarmDude5967
Рет қаралды 10 М.
FIRE PUMP How to perform annual Fire pump test.
7:00
Fire Technician101
Рет қаралды 56 М.
Q & A Session on Inspection, Testing and Maintenance and NFPA 25
1:37:31
Project  - Residential Fire Safety Inspection FF2
9:50
DJG Images
Рет қаралды 3,2 М.
小丑在游泳池做什么#short #angel #clown
00:13
Super Beauty team
Рет қаралды 34 МЛН