API 510 Internal // AEU exchanger inspection part 1

  Рет қаралды 1,820

Mr Eric

Mr Eric

Күн бұрын

API 510 Internal inspection with varying corrosion

Пікірлер: 19
@سوسو-ه9ث
@سوسو-ه9ث 3 жыл бұрын
Thank you Mr. Eric for sharing like this kind of videos. we would like to watch more of your real work videos
@MrEric_API
@MrEric_API 3 жыл бұрын
Arif, my plan is to keep making videos. Tell everyone, and let's hear what kind of subjects are of interest.
@ExaILt
@ExaILt 3 жыл бұрын
Eric, getting ready to take the 510 exam in September. Your 510 videos are helping me get in the zone
@MrEric_API
@MrEric_API 2 жыл бұрын
Glad you liked the video. Mr. Eric
@lejohns2
@lejohns2 3 жыл бұрын
Good video mr eric
@MrEric_API
@MrEric_API 2 жыл бұрын
Thank you kindly, one of my earlier videos.
@andygregory2145
@andygregory2145 2 жыл бұрын
Is this pre cleaning inspection? The brownish deposits on the shell, are they process deposits
@MrEric_API
@MrEric_API 2 жыл бұрын
Andy, this is the base metal as found. No progress debris was present.
@mohdfirdausosman6238
@mohdfirdausosman6238 8 ай бұрын
hi mr eric, What types of corrosion found in the heat exchanger shell?
@MrEric_API
@MrEric_API 7 ай бұрын
This corrosion was mainly MIC type corrosion. samples of the corrosion and process debris was taken and tested for the presence of biological colonies, it was VERY high. Mr Eric
@georgeclapenstein7823
@georgeclapenstein7823 3 жыл бұрын
That 1” or 1.5” threaded nozzle attachment weld(at the end of this vid) is all but gone. Was it recommended for a repair?
@MrEric_API
@MrEric_API 3 жыл бұрын
1" with a plug. I recommended replacement of the entire shell assembly....... I believe it was returned to service, with a new bundle.
@wakeupbeb
@wakeupbeb 2 жыл бұрын
what is your recommendation??
@MrEric_API
@MrEric_API 2 жыл бұрын
The vessel runs at 20 psig, in a bank of double-fours. It comes out of service every other year. I recommended to look at it @ the next OOS interval. I don't expect the corrosion to be any different, though time will tell.
@wakeupbeb
@wakeupbeb 2 жыл бұрын
@@MrEric_API to be monitor ?
@wakeupbeb
@wakeupbeb 2 жыл бұрын
@@MrEric_API hello mr eric.. can your tech us how to calculate pitting and thinning on vessel.. how to do it
@MrEric_API
@MrEric_API 2 жыл бұрын
@@wakeupbeb I'll add it to the list of upcoming video content. MrEric
@kay486
@kay486 4 жыл бұрын
what kind of liquid would have been in something like this?
@MrEric_API
@MrEric_API 4 жыл бұрын
Jolly, this exchanger did have versions of oil on both sides. The sides being the tube and then the shell (that's what your seeing in this video) This is used commonly to use a hot liquid that they need to cool to heat up an incoming colder liquid. In this case the hotter liquid is on the shell side, heating up the tubes and the colder liquid in them.
API inspection // corrosion & erosion piping examples //
11:47
API 510 inspection plan of horizontal pressure vessel.
16:42
Mr Eric
Рет қаралды 3,9 М.
How it feels when u walk through first class
00:52
Adam W
Рет қаралды 25 МЛН
小丑家的感情危机!#小丑#天使#家庭
00:15
家庭搞笑日记
Рет қаралды 35 МЛН
Un coup venu de l’espace 😂😂😂
00:19
Nicocapone
Рет қаралды 14 МЛН
Government Brainwashing Expert On How To Spot Lies & Influence Anyone - Chase Hughes
2:25:42
DRVN Podcast with Leon Hendrix
Рет қаралды 2 МЛН
How to study ASME VIII Div.1 in API 510 exam?
5:16
I4I Academy
Рет қаралды 1,1 М.
Finally! Flashlights That Are Brighter Than Advertised!
20:07
Project Farm
Рет қаралды 450 М.
Welding and surface conditions of vessel internal
3:56
What's the Difference Between Paint and Coatings?
14:23
Practical Engineering
Рет қаралды 2,3 МЛН
Heat exchanger pressure test
3:25
Champion Trading Corporation
Рет қаралды 39 М.
How it feels when u walk through first class
00:52
Adam W
Рет қаралды 25 МЛН