AVR DROOP AND EFFECT ON POWER FACTOR | V. R. Venkatesan | HIMT

  Рет қаралды 47,530

HIMT

HIMT

Күн бұрын

Пікірлер: 38
@avinashkanesen53
@avinashkanesen53 6 жыл бұрын
I'm from Malaysia and this helped me a lot in taking my 4th class Oral exams .Your explaination are very clear and understandable.Thank you very much sir
@RamKumar-sl1yj
@RamKumar-sl1yj 3 жыл бұрын
Excellent explanation 🙏. 22000 times this video has already been watched . Alteast people should show some basic respect by liking it ( least way of appreciating the effort) .
@a.j1298
@a.j1298 6 ай бұрын
Thanks a lot for clear explanations. You are a teacher by definition itself.
@PAWANKUMAR-bn2ro
@PAWANKUMAR-bn2ro 6 жыл бұрын
Sir your explanation is extremely awesome.. I have watched your lecture about governor droop , reverse power .. After sailing almost 5 years ... only after watching your videos i understood the complete concept of these topics.. Thank you so much. I will be waiting to get more videos from your side.
@MrUgyentshering
@MrUgyentshering 6 жыл бұрын
Really Knowledgeable Information. It cleared my big Black Snake of doubt in my mind. The material is well explained comparative to the Gov Droop. Thank you.
@DIXITAGGARWAL93
@DIXITAGGARWAL93 3 жыл бұрын
One of the best teachers
@jjg0000
@jjg0000 Ай бұрын
best chief engineer i have ever seen
@seriousjack1
@seriousjack1 3 жыл бұрын
Thankyou sir i was having this issue although we adjusted the trimmer but our power factors are varying too much! And it happened suddenly. Now i know atleast what is the problem. Droop setting it is in AVR.
@mr.basavarajhakare5958
@mr.basavarajhakare5958 4 жыл бұрын
Very accurately explained it sir.. In my ship at present one generator is running on leading power factor during load sharing... We tried adjust the voltage by voltage trimmer in MSB.. But it was no use.. Please tell me how to adjust voltage on AVR itself.. AVR has got 3 potentiometer marked as "Usoll", "Vreg" & "Tnach".. Your reply is very helpful for me..
@akshaysahni4179
@akshaysahni4179 Ай бұрын
Hello, sir am facing the same problem rn if you tell me how to resolve it'll be very helpful. When single running all 3 AE are good enough when parallel PF is different in all 3 and one generator PF dropping till .2~.3 i changed the AVR after that AE PF is 1 only but other 2 PF is drop.
@adeebahmad7822
@adeebahmad7822 22 күн бұрын
Very nice explanation.
@kalyanasundaramsrinivasan2612
@kalyanasundaramsrinivasan2612 6 ай бұрын
Thanks a lot for your clear explanation.
@lakshandissanayake1406
@lakshandissanayake1406 2 жыл бұрын
Sir , Excellent Explanation !!!!
@shazad5444
@shazad5444 3 жыл бұрын
Very good explained, thank you very much Sir.
@nishanthagayan4900
@nishanthagayan4900 6 жыл бұрын
Sir ,excellent explanation .can you explain AVR FUNCTION USE BY ELECTRICAL DIAGRAM.
@aseefhussainmanikfan1713
@aseefhussainmanikfan1713 Жыл бұрын
well explained.. thank you sir,
@vrvenkatesan5825
@vrvenkatesan5825 4 жыл бұрын
Did you compare the no load terminal voltage? Are they equal.?. During load sharing, does the alternator with leading pf have less load current for the same kw? . Run the alternator alone adjust the voltage trimmer and check if the voltage changes.
@ambeshpandey72
@ambeshpandey72 4 жыл бұрын
Very well explained Sir,keep it up.You are the hope for those who want the knowledge in simple and quality manner.
@lubaba091
@lubaba091 6 жыл бұрын
Thanks a lot. It was explained very simply and clearly.
@powerproductionunits2169
@powerproductionunits2169 5 жыл бұрын
Sir, You made my day excellent explanation
@MukeshSingh-qp1ns
@MukeshSingh-qp1ns Жыл бұрын
When we are running two generator for ex. AE1&AE2 in parallel then during load increase no.2 AE amp increases abnormaly but AE 1 amps is ok and finaly preferential trip occurs. Plz suggest reason and solution.
@sumitmishra3194
@sumitmishra3194 Жыл бұрын
Thanks for good video Sir....
@dineshdxx
@dineshdxx 3 жыл бұрын
Very nice information 👍👍
@giri6996
@giri6996 2 жыл бұрын
Thank you very much sir
@shonith91
@shonith91 2 жыл бұрын
Thank you🙏🏽
@prakashd5295
@prakashd5295 2 жыл бұрын
Sir droop qdc pot adjusted but voltage not dropped voltage increased on load what is the reason
@shaguntandon2715
@shaguntandon2715 3 жыл бұрын
Good afternoon sir, i have a doubt, request if you can share your thoughts on the same. "Even after ensuring the no load voltages and AVR droop setting of both the generators are same , is it possible that the generators are still sharing unequal KVAR (not very significant though)?" Both generators are of same rating-1100 KVA. Both having AVR of same make and model- COSIMAT-N+ Thank you Sir.
@ragarajanc9523
@ragarajanc9523 5 жыл бұрын
Thanks sir for all this videos plss upload more video about purifier and clarifier
@saurabhnarvekar4034
@saurabhnarvekar4034 2 жыл бұрын
Sir we are facing same problem... Base load 500kw One gen running kvar 0.8 2 gen running in parallel kvar 0.5 for no1 or no3 gen and 1.0 for no2 gen... We are facing problem with no2 gen... We adjusted the droop setting in avr but still the problem is same... Terminal voltages for all gen are same without load...
@transientmatter6088
@transientmatter6088 2 жыл бұрын
This sir already passed away ......
@rlakshmanan1
@rlakshmanan1 3 жыл бұрын
Sir, As your explanation is very useful for me. i want to do clarify of my doubt , so please advise me about if will adjust the voltage for one generator by trimmer(external given potentiometer) while parallel the running of both generator, it will not affect operation. because as your said , can change the p.f and kvar. let me know? how much load% need to be maintained of both generator for will proceed the droop adjustment& acceptable range is required.
@sunitavenkatesan5430
@sunitavenkatesan5430 3 жыл бұрын
Ideally adjust the voltage setting when on no load. If it is adjusted while on load in parallel the effect will be same as explained. If v settings is increased current will increase and pf will come down. All these adjustments should be small and then check.
@BahaMaktari
@BahaMaktari Жыл бұрын
Your lectures are so precious, but your language is not clear, may you add captions to convert speech to written
@iswarmahanta6905
@iswarmahanta6905 5 жыл бұрын
Any book about the setting...
@نصرالدينجليلة
@نصرالدينجليلة 2 жыл бұрын
Thanks you please translation
@vivekkumar-vi1sw
@vivekkumar-vi1sw 5 жыл бұрын
Respected Venkatesan sir,,,very happy to see your video.fabulously accurate and as always to the point....am ur preparatory candidate...😁....if the 2generators in parallel are having fluctuations in load by upto100_150kws continuously....what would be the reason to look into?and if a governor needs attention then would any adjustments help!!
@HIMT
@HIMT 5 жыл бұрын
If the power management system is on, put it on manual and then check. If the power sharing becomes stable, then the issue is with your PMS. If the fluctuation continues then the issue could be with the governor or the engine. Start with the droop setting, check compensation; check hydraulic oil, purge out the governor if air is in the oil.
@نصرالدينجليلة
@نصرالدينجليلة 7 ай бұрын
الترجمة من فضلكم
Purpose of Droop in Governors | V. R. Venkatesan | HIMT
22:18
Cat mode and a glass of water #family #humor #fun
00:22
Kotiki_Z
Рет қаралды 8 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 52 МЛН
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 19 МЛН
POWERFACTOR,FIELD EXCITATION,FUELCONSUMPTIONS,AVR
16:12
ETO ETR EDUCATIONAL VLOGS
Рет қаралды 1,8 М.
Speed Droop in Power Control Explained
8:13
RealPars
Рет қаралды 101 М.
Power Factor Explained - The basics what is power factor pf
11:09
The Engineering Mindset
Рет қаралды 1,9 МЛН
What is the Difference between VFD and Soft Starter?
7:30
RealPars
Рет қаралды 2,4 МЛН
Speed Governors | V. R. Venkatesan | HIMT
57:42
HIMT
Рет қаралды 29 М.
Cat mode and a glass of water #family #humor #fun
00:22
Kotiki_Z
Рет қаралды 8 МЛН