Fantastic you dedicated so much time to teach others and share your knowledge. Lifesaver fella. Great stuff.
@botman7 Жыл бұрын
I never realized how much friction had to be prevented in a pump like this. Amazing how much a little oil can do
@Stoparts2 жыл бұрын
Bravo colleagues , thank you for lesson
@happymorechapungu43389 күн бұрын
Well explained thank you mate
@evgenyl.76212 жыл бұрын
Very good explanation! Thanks a lot!
@microcolonel4 жыл бұрын
It'd be interesting if manufacturers looked at superhard low-friction coatings like BAM for the slippers and the port plate.
@farmerrick9660 Жыл бұрын
Good day, I was wondering if you can maybe give me some advice, I just finished a full restoration on a small gas powered new holland skid steer, I have two of the 15 series sundstund axial piston pumps, closed loop with drive motors for the wheels, everything works great , good charge pressure and working pressure as I can drive into a pile and stall the 20hp engine, my only problem I think as I’ve never owned a skid loader is that I find it very noisy, like hydraulic whine , it just seems not right, it does get worst when warm or in lower rpm’s, I’m thinking of pulling a pump apart but I’m not sure what I’m looking for that would make this issue?, thanks for your time
@lofman4 жыл бұрын
Great video
@mubarishussain36964 жыл бұрын
Thanks a lot. Fantastic
@upward_onward3 жыл бұрын
Its through your explaination that doubts on piston Hyraulic pump got cleared. So in a variable pump the swash plate angles can be changed ? if so, is it done manually or automatically ?
@microcolonel4 жыл бұрын
Where do losses come from in a hydrostatic circuit? Aside from cost is there any reason why hydrostatic drives with wheelmotors are not a thing in road vehicles? I think it would be awesome to have a light truck which could run the powerplant at peak power or peak efficiency in any speed range, or convert peak power directly to peak torque.
@hydraulics4 жыл бұрын
Compared to electric drive, hydrostatic is very inefficient. Electric does everything you want as far as keeping engine in torque band. Deere and some others use an electric generator and motor between engine and trans of medium wheel loaders to accomplish that too. But hydrostatic is very flexible in application but all the lubrication that goes out the case drain port represents inefficiency. Hydrostatic peak efficiency might be 85 to 90%. Diesel-Electric does 95% plus efficiency for way less $
@yohanrathnayaka80962 жыл бұрын
Thank you
@Andrerealworld3 жыл бұрын
Thank you 😀
@HYDRA_GAMING922 Жыл бұрын
Thanks sir
@barstasdemir709 Жыл бұрын
why pumps are designed with an odd number of pistons(7 or 9) 
@hydraulics Жыл бұрын
I was told it reduces pulsation. If even #, there'd be one piston at TDC and one at bdc of stroke simultaneously.