Bad txv symptoms | expansion valve ko kaise check kare | hvac training videos | हिन्दी اردو

  Рет қаралды 11,136

The Tech HVAC

The Tech HVAC

3 ай бұрын

Bad txv symptoms | expansion valve ko kaise check kare | hvac training videos | हिन्दी اردو
doston is video main expansion valve kaise check karte hain ki txv kharab ya sahi ..
👉To doston agar aapko video achha laga hai to please channel ko jaroor subscribe kar len 😍 / @thetechhvac
🔺👉 PLEASE JOIN HAMSTER KOMBAT LINK . t.me/hamster_kOmbat_bot/start...
✅ FACEBOOK PAGE 👉 profile.php?...
✅ INSTAGRAM 👉 / thetechhvac
TOPIC RELATED VIDEO 👉
✅ carrier package ac wiring 👉 • package ac wiring |hva...
✅ york package ac wiring 👉 • York package ac unit |...
✅ trane package ac wiring 👉 • Trane package ac wirin...
✅ SKM package ac basic wiring detail 👉 • SKM package AC wiring ...
💥〉MY VACUUM PUMP MULTI PURPOSE USE 👉. Hoxyn Value Double Stage Vacuum Pump VE - 2100N, Capacity Of 340 liters/min Specially Design for Laboratory Purpose. amzn.to/4bAsc4g
💥〉VACUUM PUMP FOR HVAC 👉 Hoxyn Dual Stage Vacuum Pump VE -245 N, Double Stage High Pressure, Capacity of 142 L/min For Specially designed for Laboratory Purpose) perfectly used with every product where vacuum is required. amzn.to/3XUse3F
💥 〉VACUUM PUMP FOR DOMESTIC AC 👉 Hoxyn Vacuum Pump VE 115N Pump, Single Stage High Pressure, Oil Capacity of 250 ml Flow Rate 57 liters/min and 1/4 HP | Specially Design for For Laboratory Purpose With One Oil Bottle. amzn.to/45TMRiH
💥〉MY DIGITAL CLAMP METER 👉 Kyoritsu KEW 2117R AC Digital Clamp Meter 1000A 600V AC True RMS KEW 2117R Japan. amzn.to/4cuXrza
💥〉MY ALL IN ONE CHEAPEST DIGITAL CLAMP METER FOR PCB CHECK 👉 Themisto TH-M98 Digital Multimeter (Black 2000 Counts). amzn.to/3zHxiOO
💥〉ALL IN ONE LEAK DETECTOR 👉 Elitech HLD-100+ Refrigerant Gas Leak Detector Halogen Leak Detector HVAC CFCs HCFCs HFCs. amzn.to/45VmmcG
💥〉MY MANIFOLD GAUGE 👉 Mastercool (59161) Brass R410A, R22, R404A 2-Way Manifold Set with 3-1/8" Gauges, 3-60" Hoses and Standard 1/4" Fittings amzn.to/3XR1LUV
💥〉SCREW DRIVER SET 👉 SPARTAN BS-02 8-in-1 Pc Screw Driver Kit With 3 Flat Blades, 3 Phillips Head, 1 Round Poker Bar, Extension Rod| Multi-purpose Tool Set Screwdriver Set (Multicolor). amzn.to/4cNwmXq
💥〉TAPARIA 1013 Hanging Pouch Screw Driver Kit (Set of 8), green & chrome, 8 screw driver 713, 922, 725, 828, 912, 712, 937, p5 861 75. amzn.to/3VO9jVK
💥〉Enon 12V Cordless Drill Machine For Home Use|Cordless Screw Driver Machine|2-Speed, Led, 0-1500Rpm|1-10Mm Chuck For Home Use|Drilling, Wood, Metal And Pvc Etc.|Heavy Duty, 1500 Mah Battery - Black. amzn.to/4cA93AQ
your queries :-👉
txv
bad txv symptoms
bad txv
txv troubleshooting
txv symptoms
symptoms of bad txv
bad txv valve symptoms
txv common symptoms
how to know if the txv is bad
txv valve
txv troubleshooting tips
piston vs txv
txv replacement
how to diagnose a bad txv
failed txv
bad txv troubleshooting
bad expansion valve symptoms
xpansion valve symptoms
expansion valve symptoms
symptoms of bad expansion valve
13 symptoms of a bad expansion valve
bad txv 410a
expansion valve
thermostatic expansion valve
expansion valve how it works
expansion valve ko kese check karte hain
expansion valve faulty
capillary type expansion valve kaise check kholen
ac ka expansion valve kharab hoga kaise thik kare
expansion valve kaise kam karta hai
expansion valve ka kaise kam karta hai
capillary type expansion valve kaise clean karen
Disclaimer:- Some contents are used for educational purpose under fair use. Copyright Disclaimer Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research Please contact for any copyright related issue.
#airconditioner #hvac #repair #hvacr #packageac #hvactrainingvideos #txv #expansionvalve #troubleshooting

Пікірлер: 44
@AhmedAhmed-lz1ke
@AhmedAhmed-lz1ke 2 күн бұрын
Aoa Very knowledgeable Explanation Thanks
@acmagd771
@acmagd771 8 күн бұрын
Very clearly explained
@altafhossain1574
@altafhossain1574 Күн бұрын
Thank you 🙏
@mkaleem9824
@mkaleem9824 2 ай бұрын
You are the best in our technician group
@Salmanhvacsystem
@Salmanhvacsystem 28 күн бұрын
Hamesha ki tarh 👌👌 maa shaa ALLAH ALLAH or kamiyabi de apko
@technicianmulajim7020
@technicianmulajim7020 13 күн бұрын
Thanks you 👍
@user-ww8ml2nt5s
@user-ww8ml2nt5s 3 ай бұрын
Thanks achhe se samchhaya h
@SaleemKhan-es1ru
@SaleemKhan-es1ru 3 ай бұрын
Thanks bade Bhai
@khurseedkhanvlogsofficial
@khurseedkhanvlogsofficial 3 ай бұрын
Nice video bro
@lailamajnu199
@lailamajnu199 Ай бұрын
Yes, good job 👏 👍
@thetechhvac
@thetechhvac Ай бұрын
Thank you! 😃
@sattarkhanjee7103
@sattarkhanjee7103 3 ай бұрын
Thanks for your sir ❤❤
@thetechhvac
@thetechhvac 3 ай бұрын
Most welcome
@raheeztp3158
@raheeztp3158 3 ай бұрын
👍👍👍👍
@bachpankakhel.648
@bachpankakhel.648 3 ай бұрын
Thank you for everything help and support brother.❤
@thetechhvac
@thetechhvac 3 ай бұрын
Always welcome
@SaleemKhan-es1ru
@SaleemKhan-es1ru 2 ай бұрын
Assalamualaikum Bhai. Sir g unit freezing ka connection aur uski checking ke bare ek basic se video upload kariye
@thetechhvac
@thetechhvac 2 ай бұрын
freezing matlab ..?
@mohammadesamuddin3912
@mohammadesamuddin3912 28 күн бұрын
Aslm bhai AK prablam Ara back pressure barabar Ara pirbi cooling nai Ara section pipe het hura prablam kya hai
@SaleemKhan-es1ru
@SaleemKhan-es1ru 2 ай бұрын
Evaporator coil pe laga hota hai jaise LP HP jaisa hota shayad suko anti freezing switch bolte hai Bhai
@thetechhvac
@thetechhvac 2 ай бұрын
ji han ...✅
@jollyscaria1922
@jollyscaria1922 24 күн бұрын
Expasion valve chockup ok lecking not working flusin and topset replcinv mechionsreolasinv gas cherging tocoveremoveing pin adjusting full fluhingsystom systom fuldion and norm fitef ok chocup rrplcing methad snd los didd high sidd e expshion topset removring ned replcing solveing porbels and unbalcing fixed ok systom poperly fixed ok systom vacuomed and systom gaumd vacum pump revalve coldd 2sidd vacom off and cherging lind fixid ok has cherging purging and methas pesged 35 mored ok iquked cherv 50t0 60cherging amper checking ok
@mahamdulhasan6892
@mahamdulhasan6892 Ай бұрын
Package Ac kah Honeywell thermostat Kece Automatic Kece Hoti hae oskah Display meh Automatic sensor kider lagta hae Or Honeywell thermostat kider lagnah chaiyee os barmeh ake details practical video upload kare brother ❤
@thetechhvac
@thetechhvac Ай бұрын
Insha Allah brother 🤝 ✅ ⏰
@tanveerkhan3477
@tanveerkhan3477 Ай бұрын
Zamil 6.5 ton package unit hai evaporator with expension an dryer an compressor allchang but ritrun not coming compressor over hit hoke tip kar Raha hai keya rission ho Sakta hai
@thetechhvac
@thetechhvac Ай бұрын
kuchh main aapko step bata raha hoon jisko aap follow karke apni problem solve sakte hain . lekin sab se pahle condensor ki kya condition hain jyada weak to nahi hai ( damage ) . agar ok hai to condensor coil proper neet and clean hai ? . follow this step 👉 sabse pahle aap compressor aur dryer filter lagane se pahle system ko flush / clean kar len ( R 11 ya R141 with nitrogen ) condensor coil ko alag se aur evaporator ko alag se . ab dryer filter aur compressor ko fit kar len . compressor agar aap naya use kar rahe hain to koi baat nahi lekin agar aap used compressor laga rahe hain to aap usko achhe se check kar len jaise kitna pressure hai , amps kitna le raha hai , sound kaisa hai kahin koi noise to nahi hai jisse hame maloom chalta hai ki mechenical ki kya condition hai , fir oil check kar len . ab iske baad system ko 500 micron vaccum karke gas charge karen . yaad rahe gas quality bhi matter karti hai cooling ko effect karne ke liye . to hamesha achhi quality ki gas use karen . ummeed karta hoon aapke sawal ka jawab mil gaya hoga 💚
@muhammadnaveed9382
@muhammadnaveed9382 18 күн бұрын
Back pressure 90 low hy or Head pressure 270 bhi low hy gas R410 charge krta hon to wo bhi charge nhi hoti kia reason ho sakti hy please guide me
@Technician613
@Technician613 4 күн бұрын
sir ek 9 tr ki unit hai voltas ki jo aapne wo sab kuch ok hai par awaaj karte hai bhut jyada or firr trip ho jata hai 20second bad plzz reply
@thetechhvac
@thetechhvac 4 күн бұрын
discharge pressure aur amps kitna hai?
@rajjakali4178
@rajjakali4178 10 күн бұрын
Bhai compressor 30 minutes chalne k bad back pressure badh jata hein wor thanda hona band kar deta hein, scroll compressor 10 tr ka hein. Kya ho jakta hein?
@SyedSher313
@SyedSher313 2 ай бұрын
Bhai Heat Pump hai usme 4 way reversing valve laga hua hai...Heating mode mein suction aur discharge pressure normal running karta hain but cooling mode me dalne se suction pressure pura down hojata hai approx 20PSI aur filter drier bhi bahut thanda hota hai aur cooling mode bhi show nahi karta hai display mein.
@thetechhvac
@thetechhvac 2 ай бұрын
agar cooling mode par chalane se dryer filter thanda hota hai to aapka filter chock hoga . filter normal ya thoda sa heat hona chahiye ye good condition hai aur thanda hai to iska matlab filter chock kar raha hai ( filter change karna padega ) NOTE ;- kabhi kabhi reversing valve agar problrm karta hai to bhi aisa problem aa sakta hai
@dariwalaladka
@dariwalaladka Ай бұрын
Bhai agar expansion valve kharab hai aur usko main remove karke direct kardu to kya cooling me koi effect pare ga ??
@thetechhvac
@thetechhvac Ай бұрын
ji han bagair expansion valve ya capillery cooling nahi hogi ( expansion valve ya capillery high pressure liquid ko low pressure liquid main convert karti hai jisse system main cooling hoti hai aur agar expansion valve remove karke direct kar denge to high pressure liquid , low pressure liquid main convert nahi hoga aur jisse cooling bhi nahi hogi . aur agar aasan way main samjhane ki koshish karoon to itna yaad rakhho ki jitna gas ka pressure kam hoga utna hi temp. gas ka kam hoga to jab tak kam pressure nahi karenge tab tak gas thandhi nahi hogi ... ummeed karta hoon aapko samajh main aa gaya hoga 🤝
@dariwalaladka
@dariwalaladka Ай бұрын
@@thetechhvac main yeh kehna charaha hu ke distributor aur capillery tube rahega sirf expansion valve ko remove kardu to kya koi problem hoga
@thetechhvac
@thetechhvac Ай бұрын
ji han problem hogi ! ( distributor aur capillery tube jisko aap rakhne ko bol rahe ho wo gas ke flow ko sirf distribute karegi na ki high pressure liquid ko low pressure liquid main convert karegi . jo distributor ke sath capillery tube lagi hai wo as distributor ka kaam karti hai na ki capillery )
@dariwalaladka
@dariwalaladka Ай бұрын
@@thetechhvac thanks bhaiya ❤️
@Technician613
@Technician613 3 күн бұрын
sir ji high pressure 500 pe chala jata hai on hote hi or low pressure 60 pe rahta or fir ekdum band ho.jata hai
@thetechhvac
@thetechhvac 2 күн бұрын
system main chocking to nahi hai ❓
@bikashtamang5158
@bikashtamang5158 25 күн бұрын
भाई अापका अावाज सहि नहि अाराहा है समझ मे नहि अाया।
@karthikn4176
@karthikn4176 3 ай бұрын
Very helpful video bro
@thetechhvac
@thetechhvac 3 ай бұрын
Glad it helped❤️
@ranadastgir3690
@ranadastgir3690 3 ай бұрын
Please explain one video thanks Lp HP switch close and open katny pressure pay hota han R22 R 410 and R134a R32
@thetechhvac
@thetechhvac 2 ай бұрын
watch this video 👉kzbin.info/www/bejne/i6HOfmeBjLiZd9E
how to check compressor | compressor check kaise kare. hvac
22:31
The Tech HVAC
Рет қаралды 97 М.
A little girl was shy at her first ballet lesson #shorts
00:35
Fabiosa Animated
Рет қаралды 17 МЛН
Slow motion boy #shorts by Tsuriki Show
00:14
Tsuriki Show
Рет қаралды 10 МЛН
Lehanga 🤣 #comedy #funny
00:31
Micky Makeover
Рет қаралды 18 МЛН
(TXV) Thermostatic Expansion Valve Operation with Pressures! 3 HVAC Scenarios!
6:45
Ductable ac service step by step .
7:41
DIGITAL AC SOLUTION
Рет қаралды 26 М.
HOW TO ADJUST A TXV ON A WALK IN FREEZER LIKE A PRO
8:56
Dnoorian
Рет қаралды 163 М.
Thermostatic Expansion Valve || TXV adjustment ||  TXV faults
11:48
FK mech official
Рет қаралды 18 М.