In this video I go through a simple preventative maintenance on a rooftop package unit
Please consider subscribing to my channel and follow me below
Social Media
Facebook www.facebook.c...
Instagram / curioushvacguy
For any inquiries please contact me at
curioushvacguy@gmail.com

Пікірлер: 41
@Imwright720
@Imwright720 5 жыл бұрын
At church this past Saturday the unit started squealing. Because I watched one of your videos I knew how to diagnose it. I knew to take the belt off and let the motor run to see if it was indeed making the noise. If not then to check the bearing play on the squirrel cage. I didn’t get to do it but at least I knew where to start. I’ve always enjoyed problem solving and so far have been able to repair my own a/c anytime something happened. A lot of times things you learn help somewhere else in life. My wife always wonders why I watch so many different types of videos, that’s why.
@thefreshride1510
@thefreshride1510 Жыл бұрын
Hi brother or friend. I just found your channel and videos. I really like them and you get a new subscriber. Greetings
@jrh86
@jrh86 10 ай бұрын
Useful and helpful yet again thanks
@davejohnsonnola2758
@davejohnsonnola2758 5 жыл бұрын
Very cool,thanks for the walk thru on the roof. We are still upper 80s overnight in late September with an eye over the shoulder for hurricanes, but looking forward to your pre-winter heating checkup follow thru. Gracias!
@davejohnsonnola2758
@davejohnsonnola2758 5 жыл бұрын
No, my former home in the mountains of Costa Rica is much cooler and too far south for hurricanes. I'm in New Orleans, LA.!
@actechformallyyomama746
@actechformallyyomama746 5 жыл бұрын
Remove contactor covers and inspect the points. Check the wires on the disconnect. Now on the line voltage connection of the transformer. The biggest problem I found was on a call for heat. The transformer was hooked up like that one with 208v to the unit and the factory hooked it to the 230v connection. The electric heat would run for just a couple minutes and cycle off. The thermostat was set to 90 and it was about 40 degrees in the space. It had an old mercury thermostat. The low control voltage was over heating the heat anticipator so the stat would satisfy. Then cool down in the 40 degree room rather quickly and cycle the heat back on. Took me a while to figure this out. On a 20 degree roof and a frozen brain things go slow lol. Not many of those stats around anymore. I don’t know if they teach about heat anticipators any more.
@texasbread107
@texasbread107 4 жыл бұрын
Thank you so much for this I’ve just recently got into Commercial HVac and I’ve been kinda lost doing these PM’s
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
no problem- any questions, feel free to email me curioushvacguy@gmail.com
@abdulrehmanakram.3030
@abdulrehmanakram.3030 2 жыл бұрын
i like ur videos. u make very good videos
@anthonycanty3755
@anthonycanty3755 2 жыл бұрын
Great video
@ramonmolina2394
@ramonmolina2394 2 жыл бұрын
Great job!
@jeffpook9471
@jeffpook9471 3 жыл бұрын
just learning, by taking using your return temp that could be used as your wet bulb temp, if you had to put on your gauge set, good video just found it
@bryantylerservices
@bryantylerservices 5 жыл бұрын
Another great video.. Like the comment on pressures.. Could be looking for trouble.. Unless its required per a realtor on a inspection ,before selling home.. Thx again! Bryan Tyler Refrigeration
@kcomfortsystemshvac7060
@kcomfortsystemshvac7060 4 жыл бұрын
Great video,professional explanation,,,,,,I have litle question,,,,somthimes,,do you come cross whit the ICM 220 relays lock out ? How do you deal whit it,,,.?
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
Hey L Mechanical - I honestly dont mind them, I havent seen them a bunch in my area and havent had any issues with them. Have you had a bunch of issues with them? if so what sorts of issues? feel free to email me as well curioushvacguy@gmail.com
@fernandorosillo9715
@fernandorosillo9715 3 жыл бұрын
Great job.
@SweSuf
@SweSuf 5 жыл бұрын
How often do you find problems during PMs? Of course it varies, but is one in ten, almost every time, or something else.
@miltoncastro935
@miltoncastro935 3 жыл бұрын
hey i do the same capacitors under load the same way 👍👍
@zachtruax3222
@zachtruax3222 5 жыл бұрын
Here in Indiana I’ve always been told outdoor units have to have a freeze plug in the trap to prevent the trap from breaking in freezing weather. Do you guys not use those or does it not really matter? Love the videos, very informative. Keep up the good work
@johnnyb8629
@johnnyb8629 3 жыл бұрын
When you been in the trade as long as I have , you get a equally long list of things not to do. I have had bosses who insisted on us using a co2 to blow out the control compartment of cob webs and dust, this was from an experience he had when a tech did a PM and the facilities guy opened the panel after him and seen it full of cob webs and concluded no PM was done. Blowing the control compartment out with CO2 can be a good idea but the problem is that if you are too close to the components or if its just too strong you can blow the springs out of the contactors and not notice. I have done this myself and its fine until it pulls in then its locked in and will not shut off. so, in short, you can actually cause damage if you mess with the unit too much. When checking charge on a Lennox with 4 compressors in a row , you notice the first compressor under charged and the last one over charged, because tech putting gauges on every summer and taking the charge from the first one and dumping it in the next because they don't dump the gauge charge back in when removing gauges.
@aaronvigil9910
@aaronvigil9910 2 жыл бұрын
Hey Jonny I’m looking to get into HVAC but more specifically HVAC Building Maintenance working at College doing HVAC is much easier/better doing than your typical residential HVAC? Thanks :)
@johnnyb8629
@johnnyb8629 2 жыл бұрын
@@aaronvigil9910 it can be but it's facilities work. I expect you could run into PTAC units, small residential furnaces in dorms. You may see a lot of crazy disgusting shit, my brother in law did that very same work at Tulane University in New Orleans and some of his stories were bad. I personally wouldn't do that work. Depending on where you are in climate zone you might see some big steam or hot water boilers for radiant baseboard heating, but it will all be the same stuff over and over. Working for commercial contractor you see something new everyday, new and different equipment new and different problems and troubleshooting everyday. I've been working in Chicago my whole life and still run into new and weird stuff. The last thing I remember seeing that I had never seen before was a external motor compressor still using R12. Crazy huh.
@aaronvigil9910
@aaronvigil9910 2 жыл бұрын
@@johnnyb8629 Thanks for the quick reply! I live in Colorado. It’s kinda hard to tell. I’ll be on call every 9 weeks for one week. So that’s not too bad. Maybe just changing filters and stuff but yeah never thought of working on dorm rooms. Not sure if they have PTC or not.
@HVACNOEL904
@HVACNOEL904 Жыл бұрын
prefect
@chrisscerbo5731
@chrisscerbo5731 4 жыл бұрын
hey, what's your opinion on micro channel coils. I'm not a big fan, but would like to see what you think of them. no rush on reply
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
Hey Chris- Im not a huge fan of them just because there so fragile, I prefer the old school beefy tube and fin coils myself but also I havent had as many issues with micro channels as most guys, I cant remember the last time I even had a leaking microchannel
@sudeshputran69
@sudeshputran69 3 жыл бұрын
Super
@dubaistories7154
@dubaistories7154 3 жыл бұрын
Very informative
@sparkytech8787
@sparkytech8787 4 жыл бұрын
LOL common sense school love your vids
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
Thanks, I think, lol
@johnnyb8629
@johnnyb8629 3 жыл бұрын
Im curious, how do you do coil repairs when you have a condensing coil with a hot gas line that rubbed threw where it passes threw the metal tube sheet?
@yzhang8629
@yzhang8629 3 жыл бұрын
12:15 exhaust is close to the gas pipe, is it really safe?
@Dave-dr4yy
@Dave-dr4yy 5 жыл бұрын
When your hat sticks to the fan on the top it’s probably about 200 cfm. 😂
@henryesp9284
@henryesp9284 4 жыл бұрын
How long does it take you to complete the maintenance?
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
Really depends how in depth the customer wants me to go and how many units they have- but on average a really in depth summer pm with coil cleanings can take 2-4 hours per unit, but again theres alot of variables there
@PBS-nm1uu
@PBS-nm1uu 4 жыл бұрын
Please do some troubleshooting of the circuit boards.
@pabloantonio9507
@pabloantonio9507 3 жыл бұрын
Badass
@rono3045
@rono3045 3 жыл бұрын
All that and you never changed any filters in the store or checked CFM
@johnnyfair1005
@johnnyfair1005 4 жыл бұрын
Lloked like it had a surveyor ems system
Commercial HVAC Preventative Maintenance
19:16
HughesMan HVAC
Рет қаралды 8 М.
HVAC Preventive Maintenance is a SCAM!!
9:02
Quality HVACR
Рет қаралды 20 М.
哈哈大家为了进去也是想尽办法!#火影忍者 #佐助 #家庭
00:33
火影忍者一家
Рет қаралды 122 МЛН
World‘s Strongest Man VS Apple
01:00
Browney
Рет қаралды 44 МЛН
这到底是怎么做到的 #路飞#海贼王
00:10
路飞与唐舞桐
Рет қаралды 4,1 МЛН
No AC in the Kitchen, please help
19:42
Curious HVAC Guy
Рет қаралды 6 М.
Preventative Maintenance Strategies for Plumbing Systems
11:40
Slipstream
Рет қаралды 2,7 М.
All 3 Ac units not cooling
24:47
Curious HVAC Guy
Рет қаралды 9 М.
Rooftop Bone yard
5:51
Curious HVAC Guy
Рет қаралды 4,9 М.
Preventative Maintenance Strategies for HVAC Systems
11:20
Slipstream
Рет қаралды 4,7 М.
Commercial HVAC Preventative Maintenance
16:34
HughesMan HVAC
Рет қаралды 27 М.
Commercial HVAC Preventative Maintenance Vlog
15:32
HughesMan HVAC
Рет қаралды 1,3 М.
Quick emergency calls
22:53
Curious HVAC Guy
Рет қаралды 9 М.
HVAC cooling season, rooftop unit p.m tips, tricks and what to look for
19:12
No AC, Trane package unit not cooling
13:08
Curious HVAC Guy
Рет қаралды 89 М.
哈哈大家为了进去也是想尽办法!#火影忍者 #佐助 #家庭
00:33
火影忍者一家
Рет қаралды 122 МЛН