Basics of Access Control

  Рет қаралды 299,876

Kantech Support

Kantech Support

Күн бұрын

A first look at access control for beginners

Пікірлер: 38
@allaroundsecurity1794
@allaroundsecurity1794 5 жыл бұрын
Nice explanation of Access control system .
@lampoyo
@lampoyo 3 жыл бұрын
Working on these doors for the first time. Thank you!
@bakerpatrick6842
@bakerpatrick6842 3 жыл бұрын
Sorry to be so offtopic but does any of you know a trick to get back into an Instagram account?? I stupidly lost my login password. I would appreciate any tips you can give me
@rodrigoleonardo2597
@rodrigoleonardo2597 3 жыл бұрын
@Baker Patrick Instablaster ;)
@tehshittiestlogin
@tehshittiestlogin 2 жыл бұрын
A mostly overlooked component of all access control systems is the DOOR CLOSER
@TecSpec9000
@TecSpec9000 3 жыл бұрын
You should fully explain that a Request to Exit is mounted on the secure side (inside) of the door. Otherwise good video.
@GIJew
@GIJew 2 жыл бұрын
Good point. Someone who doesn't know any better would assume based off this video that it's also mounted on the outside. In reality, it's on the side we can't see.
@YolaTechSolutions
@YolaTechSolutions 11 ай бұрын
Nice detailed
@Kit_Bear
@Kit_Bear 5 жыл бұрын
Basics of Access control is a Standalone System not a Networked system but I liked the explanation. Well done.
@kantechsupport6044
@kantechsupport6044 5 жыл бұрын
It can be networked or not, there is no difference in the functioning of the system. The system described in this video is a networked EntraPass system.
@23Thomasdevasia1992
@23Thomasdevasia1992 3 жыл бұрын
Very good explanation
@mohamednady867
@mohamednady867 3 жыл бұрын
nice its very good
@ahmedhasan6955
@ahmedhasan6955 4 жыл бұрын
Thanks for the useful informations
@user-rm6xr7oq8v
@user-rm6xr7oq8v Жыл бұрын
Hello, I have several KT-400PCBs whose heartbeat lights cannot be started, while DC, AC and network can be started. May I ask what is the problem?
@tuntunmyint1691
@tuntunmyint1691 3 жыл бұрын
thanks
@EzraMosomi
@EzraMosomi 6 жыл бұрын
Nice Breakdown there. Good Stuff!
@Stephen-lt1tp
@Stephen-lt1tp 5 жыл бұрын
The software is the hardest part
@Flawlessfox2001
@Flawlessfox2001 7 ай бұрын
Not if you use verkada. That’s the easiest access control software there is
@AngelMichael685
@AngelMichael685 3 ай бұрын
Access control λέγεται
@Pramesh31
@Pramesh31 3 жыл бұрын
what is height of t .rex sensor and connection mercury MR 51E
@kantechsupport6044
@kantechsupport6044 3 жыл бұрын
I'm afraid we do not have that information at Kantech. Contact the manufacturer of the product for installation recommendations.
@jaimestuardo4655
@jaimestuardo4655 5 жыл бұрын
Hello! I have one question about connecting REX button to KT-300. Button should me NC or NO? an illustration in the installation manual suggests normally closed, but in other documents, I have seen it could be normally opened. What is it? or it is configurable? Regards Jaime
@Kit_Bear
@Kit_Bear 5 жыл бұрын
On most systems it's N/O. (Close the circuit to open the door) Just test it with a spare wire from negative ground to the push button (REX) terminal. If it activates the relay as soon as you touch it it's N/O and if it activates as soon as you remove it then it's N/C. Hope this helps.
@jaimestuardo4655
@jaimestuardo4655 5 жыл бұрын
@@Kit_Bear Many thanks!!! Customer has another controllers KT-300 in his building. All existing doors are opened when the exit button is released, therefore all of them are N/C. I will configure the new doors the same way.
@flira3flira340
@flira3flira340 Жыл бұрын
No electricity also can use or not
@kantechsupport6044
@kantechsupport6044 Жыл бұрын
As long as you have a backup battery connected to the controller, it can work during a power blackout. The duration will depend on the usage.
@obiobalafrancis8063
@obiobalafrancis8063 3 жыл бұрын
Were is the access controller positioned
@kantechsupport6044
@kantechsupport6044 3 жыл бұрын
It could be positioned as far as 1000 feet away. Only the installer can answer that question
@JonTheChron
@JonTheChron 3 жыл бұрын
Usually in a server room, a telecom room, a closet, above a door (secured side) or any other secured location.
@antonhristov1926
@antonhristov1926 4 жыл бұрын
Can I install 2 card readers on both sides of the same door
@kantechsupport6044
@kantechsupport6044 4 жыл бұрын
It really depends on your equipment. If you are using a KT-400 or a KT-1, you can if using ioProx or ioSmart readers. Please contact technical support if you require any additional information
@newzealandgurusinghproduct7917
@newzealandgurusinghproduct7917 3 жыл бұрын
on gallagher, yes u can. just need to program and assign to the door
@Mr1bigsexy
@Mr1bigsexy 4 жыл бұрын
No one actually shows how to hook all this up to a power supply
@kantechsupport6044
@kantechsupport6044 4 жыл бұрын
All the wiring diagrams are available in the controller manual available in the technical library of our website. www.kantech.com
How to setup an access control system using zkteco f18 device
13:41
Tech Inside Out
Рет қаралды 9 М.
OMG what happened??😳 filaretiki family✨ #social
01:00
Filaretiki
Рет қаралды 12 МЛН
Intro to Access Control: Prox & Smart Cards
11:17
SchlageSecurity
Рет қаралды 27 М.
HID Signo Reader Installation & Wiring
5:37
HID Academy
Рет қаралды 49 М.
POP3 vs IMAP - What's the difference?
7:50
PowerCert Animated Videos
Рет қаралды 1,4 МЛН
How RFID Works? and How to Design RFID Chips?
9:07
easyELAB
Рет қаралды 232 М.
2024 Ubiquiti Unifi Door Access
12:16
Lou Filla
Рет қаралды 15 М.
Installation of Brackets with Electromagnetic Lock for Glass Doors
3:26
OMG what happened??😳 filaretiki family✨ #social
01:00
Filaretiki
Рет қаралды 12 МЛН