I could sit a listen to Roy talk about boilers all day the mans knowledge is second to none. What a asset he is to viva training!
@SuperVitz Жыл бұрын
Thanks to this video I have fixed our Main 24he. We bought a property with this old combi in and wanted to keep it going a bit longer before replacing with something more modern. Our boiler wouldn't fire unless there was a large amount of flow from the hot water taps, requiring two taps to be opened almost all the way for the diverter pin to fully extend and engage the microswitch. I had removed the diverter valve body and fully rebuilt it using a rebuilt kit from eBay, but this made no difference. Watching your video, I then discovered the hydraulic Venturi. This was an even bigger faff to remove, but eventually got there with a 24mm wrench. The plastic part had disintegrated and the spring was loose in the hydroblock. I fished it out and replaced it with a new £15 replacement from eBay and now the boiler works as intended. Surprisingly none of the gauze filters were blocked on this old boiler and everything was quite clean. I also removed the differential pipes and flushed them out with water and air. I have degrees in mechanical engineering and electrical engineering and currently work on designing building control systems, but I will be having a gas safe engineer come and check everything over before we move in to the property. Cheers.
@AllenHart999 Жыл бұрын
Thank You
@PaulBrydges-i6x2 күн бұрын
Thanks for this video never knew there we filters under the boiler fix the problems i had
@chrisgibson58033 жыл бұрын
Allan you’re a step ahead with the training. I hope you get recognition for your efforts. Best of luck pal.
@bobbojones8157 Жыл бұрын
I’m in awe of your knowledge . When I was working combi boilers only came in half way through my career they were and still are more trouble than they are worth just so many things that can cause problems
@kishore099 Жыл бұрын
Roy, you are a genius. 10/10. Not only an expert with vast experience, rare ability to explain and make it understandable to ordinary viewers. I know the video is for trainee engineers but ordinary householders can understand the workings and complexity of diverter valves.
@AllenHart999 Жыл бұрын
Thank You
@1000Zebedee10 ай бұрын
What a fantastic breakdown and explanation of how these parts interconnect in a combi boiler. Thanks for the video🙂
@paulcopland66783 жыл бұрын
One of the best explanations i have seen Roy..keep it up Allan
@rocketman2463 жыл бұрын
Excellent video! Seemed like I’ve actually sat in the training classroom 😀
@tonyf2669 Жыл бұрын
Very useful suggestion on ensuring the small pipe off the rear mounted bypass which feeds the pump proving diaphragm and associated microswitch isn't blocked. Great video.
@AllenHart999 Жыл бұрын
Thank You
@StuHNomadBiker2 жыл бұрын
Brilliant video, I'm a breakdown engineer and learned a couple of things here 👍
@markm493 жыл бұрын
Love the 105 - so simple to service.
@freethink3r3 ай бұрын
Excellent! Thank you for the detailed explanation.
@michaelgreenhalgh88253 жыл бұрын
another great video Roy is a good lad had him train me when i went down to Baxi
@kosalaperera18992 жыл бұрын
Thank you, Sirs. Both Allen and Roy. love every bit of it.
@dan123collins3 жыл бұрын
Brilliant Training Roy. Thanks for sharing Alan 👍
@Timetochange763 жыл бұрын
You talk a language I understand. Great video and thanks doing it. I just wish I watched it before I spent hours repairing a main 24 he yesterday....it would of saved me a lot of time. ☺
@efrygasservices61693 жыл бұрын
Cracking video here guys 👍
@suheilhanna8733 жыл бұрын
As usual, 💫💫💫💫💫 can't find better teaching than this 🌹
@Asfiya672 жыл бұрын
thanks Alan and Roy very helpful video
@craigpriest86613 жыл бұрын
Brilliant video Roy. 👍
@NicholasPollard-k8z Жыл бұрын
Thanks the filter in the return seems to solve my problems 👍
@manohardevgun6543 Жыл бұрын
Hi Allan you are great explaining in deep depth. on my Bexi duo tec it take long time to get hot water going when heating is off. what could be be the problem? manohar
@MobinC973 жыл бұрын
Cracking video Allen cheers
@namesanmanname2972 жыл бұрын
Excellent video. Very good explanation.
@ashokrawal38203 жыл бұрын
Always great videos, Many thanks
@rodknee873 жыл бұрын
Brilliant, loads of useful info, cheers
@themadhatter47613 жыл бұрын
Fantastic video, great explanation of the operation, excellent. 👍👍👍👍🇬🇧
@sheriefgerges77893 жыл бұрын
Great video I would like to ask it will part numbers for metal washer for thermistor, water flow restrictor
@rickycunningham63683 жыл бұрын
another great video Alan. loving the channel and content its proper interesting your a top bloke mate
@ismailcelikkol29752 жыл бұрын
Great video, fantastic. thank you for that splendid work sir.
@colin50643 жыл бұрын
Great video all the info and tips you require to know
@TheCabbycol3 жыл бұрын
Another great video, keep them coming
@gasfitter783 жыл бұрын
Great video again.
@DD-eh9cp9 ай бұрын
Could do with a breakdown of each of the service kits for this hydraulic section with part numbers. Any chance of revisiting this training video and adding them?
@robjenkins9450 Жыл бұрын
Great explanation Roy. Would you happen to have a cutaway of a 105 Instant diverter valve. That would be equally useful.
@AllenHart999 Жыл бұрын
No, sorry
@davesaxon73483 жыл бұрын
Great video, well explained. Cheers
@Capitaldoc3 жыл бұрын
Mate you doing a great job. God bless
@1Mattza3 жыл бұрын
Well done lads very informative, thank you 👍
@leaturk113 жыл бұрын
Great training, thanks chaps.
@hazelbulgin6383 жыл бұрын
Great video lots of good information again quality
@S.Hitchcock Жыл бұрын
Brilliant video. Very knowledgable. Can you give me some advice on my 105 please? The pressure keeps gradually rising. It doesn't rise when doing nothing. The flat plate has been renewed 6 month ago so isn't pinholed or shouldn't be.The ev is ok. The pressure rises each time hot water is used, so after a couple of days using hot water the pressure is right round and overflowing outside. Thanks. Hope I'm not in for a hefty repair bill😂
@AllenHart999 Жыл бұрын
Sounds like the boiler could do with a service and the expansion vessel checking. it may even need a new one. Thanks.
@Hyde9991003 жыл бұрын
Another good video.....Thanks Allen......U Dah Mannn !
@richardhodgson74433 жыл бұрын
Cracking video 👍
@hardevgill242510 ай бұрын
thanks you explain very good.
@kennyjohnson86092 жыл бұрын
Great video as usual. Roy is the man on the 105’s. the brass washer for the thermistor instead of the fibre ones provided anyone know the part number for it?
@robertwhiteoak912 жыл бұрын
Found those filters on a potterton I believe it was... almost made me cry, I'd spent that much time messing about with other things 😄
@tommyblackman7119 Жыл бұрын
Great video Allen and Roy, May I ask as Roy never mentioned it, what would cause the pin on top if the diverter valve not to fully retract after demand, I have an issue where after pump has stopped the pin is half way out and still engaging the micro switch Many thanks
@lucasdoesgaming66 Жыл бұрын
Dirt on the pin stops it sliding through the stuffing box
@rhodespcrhodespc5094 Жыл бұрын
HAVE THE SAME ISSUE, RE-GRASED THE PIN ..BUT STILL STICKS UP@@lucasdoesgaming66
@cjfox75412 жыл бұрын
Hi great vidio. I have a baxi105e and had no hot water just change the heat exchanger and fab hot water. But one hour later no hot water. Any help would be appreciated cj
@thornhillplumbing3 жыл бұрын
The hydraulic Venturi can be difficult to remove. You need a 24mm ring spanner and it helps to spray it with shock release spray if it is stiff to loosen it up so you don't round it off. If the plastic part has crumbled , you can get the pieces of plastic out by removing the plate and poking the plastic out from the back. Also check in the plate for pieces of the plastic.
@sukbajwa2 жыл бұрын
Thanks for the video Alan. Can I use a 14mm socket to get that dhw venturi out
@veronicahart4503 жыл бұрын
Wonderful video
@rezuk12083 жыл бұрын
Thanks allen 🤩🤩🤩
@faizraouf9118 Жыл бұрын
Hi there got a main combi 25 got a problem the pump proving pin is continuously up and runing the pump I have changed the diverter valve the whole part but got the same problem I hope u can give me some idea ?
@sir-dil-a-lot3 жыл бұрын
Great video.
@Ace-xm9iq3 жыл бұрын
Great video 👍. Where can I find the list of part numbers?
@kckplumbingandheating3 жыл бұрын
Great vid 👍🏻
@kevindownes77632 жыл бұрын
I have a Baxi Duo-tech 28 HE A. It’s working okay, no fault codes etc. Located in a downstairs utility room. It feeds the radiators upstairs and them drops down into the lounge and onto the hallway. All the radiator upstairs get hot and the hot water supply is fine. However the radiators in the lounge and hall do not get any heat. i’ve checked and there are no blockages. The boiler has just had the DIVERTER cartridge, motor and thermistor replaced. but this has mad no difference. Any ideas what could be causing theirs. The boiler has been installed for 11 years.
@kevind71503 жыл бұрын
The small O ring at the back of the differential valve some time leaks, also. There is, a new one in the service kit. Which is sometimes over looked!
@davidharris88852 жыл бұрын
Thank you 👍
@rayc15033 жыл бұрын
Excellent content Roy, Allen and viva training. I always felt that baxi got it wrong with the GA range boilers. I have a pet hate for them, dislike working on them.
@stephenwignall6 ай бұрын
Radiators are getting warm when hot tap is running main 30 He ?
@davelaye7003 Жыл бұрын
great knoledge
@AllenHart999 Жыл бұрын
Thank You
@spartacus09ful2 жыл бұрын
What could be the culprit of the plunger not coming out enough of the pressure differential valve on the front of diverter valve for hot water. It comes out a little bit but not enough to activate the microswitch. The plunger and diagphram have been replaced with no avail. The hot water does work but only with the heating on.
@taze952 жыл бұрын
Hi, have one at the moment, hot water is temperamental, but when there’s a call for hot water the pin on the heating side doesn’t retract, the pin on the water side comes out, Boiler fires up but hot to start then goes tepid, pin on heating stays engaged with micro switch, any idea please
@davideyre2542 жыл бұрын
Hi Alan just been called out, heating not firing, pin not coming out of block, changed diaphragm, power off as system comes up to pressure pin comes out and makes contact on microswitch, asked everyone no recommendations, changed diverter valve system works everything fine now but why did pin come out after diaphragm changed
@tommyblackman71193 жыл бұрын
Great in depth video and learning new things Love knowing how things work and the cut down parts so You can see inside Also I’ve changed a few diverter valves on these boiler an a few times I’ve had the orings on the bypass leak.. Tried replacing for one of my kit box but nothing near correct size, Baxi do sell them but they don’t give you the actual size of the orings . I found thus awkward as you cannot replace this oring because not knowing the size.. would Roy know the size of the bypass oring ? Thanks
@rhodespcrhodespc5094 Жыл бұрын
ON THE BACK PART OF THE DIVERATOR IF THE PIN IS STAYING UP, THIS AFTER REPLACING A NEW DIVERATOR ON A BAXI 80 ECO...WHAT IS THE PROBLEM..THANKS
@sudhiradhikari193 жыл бұрын
Thank you very much.
@andrewwhant11542 жыл бұрын
Hi , i have a Baxi 105 HE , had a problem for some time with only getting hot water if the mixer tap is turned on full on all taps and it takes about 1 minute to get hot, as soon as you reduce the tap the burner stops and cold water , could you advice on what the problem could be, the plumber has changed the diaghram on the diverter, he saying now the diverter is faulty, would appreciate your help, thanks
@SuperVitz Жыл бұрын
Hi. Did you ever fix this problem? I have the same thing. Please let me know, thanks.
@michaelvenus85392 жыл бұрын
Is the rear plunger meant to come up when the DW plunger hits the switch?
@anthonyjackson979 Жыл бұрын
Did you find the answer mine is doing the same
@PawelLis-h6j2 ай бұрын
Thank you
@timgordon71072 жыл бұрын
Question ? Running hot water tap radiators getting warm what is this please
@ReleaseThaPressure2 жыл бұрын
Likely diverter valve issue, I'm here watching this with the same problem.
@colin50643 жыл бұрын
Hi, could you post the hydro inlet assembly filter and flow restrictor part number 12 L. As Baxi parts don't list this individually, only the full unit? MAIN 24HE HYDRAULIC INLET ASSEMBLY 248246. So how can just the required serviceable items be obtained?
@kopynd13 жыл бұрын
so what is the problem if you only get tap hot water when the radiators are on
@medmtv39752 жыл бұрын
I cleaned everything like new every piece is cleaned and waxed good water pressure the membrane is good but the hot water pin is not coming out to activate hot water mode with my hand it moves perfectly but with water the pin doesn't come out
@timewaster1959 Жыл бұрын
Why do I only get hot water when heating is also on .
@mikeystyz3 жыл бұрын
Great video Allen thanks
@janosgaborsalanczi4836 Жыл бұрын
Thanks the video, could you have me the spare part kit number?
@bahiaharjinder3 жыл бұрын
Hi allen another great informative video throughly enjoying roys boiler training its very helpful, is it possible to do one on the hydro block for the baxi instant combi he version its the one where the expansion vessel is used for pre heat would be superb if you could thankyou
@Mad4plumbing-ltd3 жыл бұрын
👍😉
@colin50643 жыл бұрын
looks like the part numbers promised at 12.min 50 on the video never made it, rather disappointing guys