Mai already thik karwa chuka hu is mistake ko and thanx sir aapki video se mujhe bahut help milti hai ek video coasting P nikaliye puri details k sath sir pls
@mirsaif57952 жыл бұрын
Sahi video banaya Bhai tum ne....
@abhishekgautam81855 жыл бұрын
Aap bahut axe se explain krte hain... Thnk u sir
@civilsitevisit5 жыл бұрын
Thanks brother aese he dekhte raho sekhte raho n share plz ❤️
@pranjalbaishya8345 жыл бұрын
thnks vaai.. mere site pe hua tha yeh mistake.. shttrng ka spprt hil gaya tha.. column ka top 55 mm hil gaya tha... fir maine twist kara k thik kiya.. galat tha pata tha.. pr sahi tarika aaj malum para.. ab se fichr chmicl use karunga..thnkss buddy
@civilsitevisit5 жыл бұрын
wlcm pranjal ❤️ keep watching
@ShadabKhan-ls4rv2 жыл бұрын
Sir you are doing great job
@adityajoundal8500 Жыл бұрын
Knowledgeable Video sir
@mirsaif57952 жыл бұрын
Yeh kaisi thanks bolna samaj nahi Ara lekin bohat shukriya is video se kai sare logon ku bohat badi madad hogayee...
@vaibhavchavan60405 жыл бұрын
Thank u sir. very helpful video for site engineer.
@civilsitevisit5 жыл бұрын
Thanks brother please shate
@awaisahmad89352 жыл бұрын
I learned best column correction method from this video, great job sir
@syedmahmood23724 жыл бұрын
This video was really very helpful Sir
@adarshallkindsgame89885 жыл бұрын
very important information Sir ji thanks
@sarthakmohapatra37384 жыл бұрын
Excellent video sir . Thnx a lot
@fasttrendiz34113 жыл бұрын
Sir foundation colum 9*18 ka tha, 5 inch jaggal kiya h, dusre ki jagah m chala gya tha , coloum uspe plinth bim bhi dal diya, ab ky kre ,
@hollywoodexplosivetrailers87119 ай бұрын
Mere isme 2 inch ka dal diya joggle
@ItsAditya_xyz7 ай бұрын
Hey, it's been 3 years. Did you have any troubles due to this?
@shouryabikashjena78344 жыл бұрын
Sir agar aisa chhat banane ke baad hua to kya karu.....?please reply
@tripuritech4627Ай бұрын
Kaunsa IS code ka reference hai please reply?
@ramchandrashrivastava36395 жыл бұрын
Very very useful video.
@priyankapanche86362 жыл бұрын
Best idea sir
@mdreyazshaikh72415 жыл бұрын
Bahut achha sir jii
@civilsitevisit5 жыл бұрын
Thanks bhai
@sunitaprasad27244 жыл бұрын
Very nice Sir Thank you so much
@awaisahmad89353 жыл бұрын
I faced this situation and corrected with the help of your video, thanks a lot sir, U r wonderful
@ImranKhan-nu2tt4 жыл бұрын
Good message 👍
@civilsitevisit4 жыл бұрын
thanks brother
@GurpreetSingh-pj4vk4 жыл бұрын
Good
@ashutoshupadhyay59285 жыл бұрын
Will you please let us know from which IS code or ASTM you are suggesting it
@ankitsingh-hg4cm5 жыл бұрын
Very very good sir Expecting more like this Thank you
@Kshitijsingh913 жыл бұрын
Same work ghar k building me v karna chahiye kya
@turtlebrains4 жыл бұрын
Kya ham chhat se naya structure taiyar kar skte hai
@Iitgstr14 жыл бұрын
Nice information 👌 Brother, thanks
@salimjave18344 жыл бұрын
Best video sir
@civilpro95375 жыл бұрын
Sir jo misplaced ho gaya hai ushe cut karke hatana hai kay ?
@civilsitevisit5 жыл бұрын
haan jo misplace ho jyta hai usko htana hota hai
@civilpro95375 жыл бұрын
instead of welding can we tight with binding wire sir ?
@pranjalbaishya8345 жыл бұрын
wire se v sayad kr sakte ho.. lekin mazbooti utna nahi milega jitna welding main milega..
@dhingranitish3 жыл бұрын
Nice content
@nitinpandharkar66465 жыл бұрын
What is your suggestion for rebar which are not in position/need to be jackled. Did you cut these rebar? Or kept as it is in column
@SandeepNayak252 жыл бұрын
just cut them
@muhammadharisbacha34664 жыл бұрын
Sir tile analysis Kai barai main vedieo bana dai
@zetchalama41123 жыл бұрын
Can same method be done if column mistakes in on first floor
@sonalibahuguna19452 жыл бұрын
Out of 16 columns, 5 Columne are misplaced by 2 to 5 inches.. plinth beam is already casted. What should be correction for this mistake ?
@perfectstranger28452 ай бұрын
How did you fix it? I’m having same problem . I think you used rebar chemical ?
@shahidiyasir43965 жыл бұрын
Bht Sahi...
@civilsitevisit5 жыл бұрын
Thanks bhai
@Rajeevkumar-qb1rj Жыл бұрын
Usko position change karne ke liye Kitna inch jogal de sakte
@sajidchoudhary34643 жыл бұрын
Sir yei to apne 230 kai grout kr leya footing k base pr sai lken slab pr sai colume out ho jaye to 230mm kai grout kaise hoga slab ki to thicknes hi 150mm ki hote hai waha kaise kre sir reply plz
@viralintwala4249 Жыл бұрын
Which IS code allow this method ?
@UmeshKumar-fm1qp4 жыл бұрын
very good
@prashantkumar-tg1wv3 жыл бұрын
Super sir
@CivilSiteadda105 жыл бұрын
Sir aap videos edit ke liye kon sa app use krte ho
@amitthakur86295 жыл бұрын
Sir agar chat par first ya second floor me hua hai to bhi same rule rahega kya
@Waseemakram-fd3oe5 жыл бұрын
thank you sir aap ni zabardase video ke hai sir
@civilsitevisit5 жыл бұрын
Thanks waseem keep watching
@chennareddyindla23494 жыл бұрын
Good.
@sachinshrivastav5174 жыл бұрын
Hilti and fisher grouting service available
@civilsitevisit4 жыл бұрын
okeah
@shivrgpandeya46795 жыл бұрын
Sir ji, Steel cut kar denge but niche se aadha steel se match kaha ho payega Jo 230mm niche dril karke dall rhe vah concrete pr rest krega n niche steel k tuch me kaise rahega
@civilsitevisit5 жыл бұрын
match ni brother ....bs insert n grout
@shivrgpandeya46795 жыл бұрын
Ha vahi, confusion ye h ki jo steel niche se continue aarha uska end karke fir dusra steel dal rhe,us continue steel se link khatm hojarha n, ye doubt h mera
@vikasgawai93105 жыл бұрын
Same doubt for me...
@ravipatel93165 жыл бұрын
Continuity will be break... we're going for newer steel with method of Rebaring... Yes, it's not as per design for spacing of vertical bars , but it's better option over jackiling of bars...
@pranjalbaishya8345 жыл бұрын
continuety brek hoga.. sahi hai.. par twist karke continue krne se grout krna bettr hai...
@harshraj73072 жыл бұрын
Bhaiyaa mere ghar ise trah dhalai ho gya 3 room ek hall sara room badguniya nikal gya stairs be tedha ho gya ab second floor aisa na iske lea kya ho seckta hai ya kuch nahi ho payega
@sachinparmar28205 жыл бұрын
Lekin sir jo sariya out ho gya usko to die marke column ke andar to lana pdega na. Ya fir out huwi bar ko cut kr lee
@pramodtiwari91985 жыл бұрын
Kya ye tarika pwd,cpwd etc Mai manya hoga?
@a94501542474 жыл бұрын
Very impressive sir... Chote plot ya structure k liye piller itne heavy nhi hote h... Aur 4bar pillar me h aur 4 hole kr k ye process krna impossible hoga?? Waha kaise kare isko???
@tanweerabbas66285 жыл бұрын
Please upload a video on substation
@civilhunt10415 жыл бұрын
sir outer peripheral ka rod agar out of actual position se nikal gaya toh kaise Karna hai... apne toh andar wala ka hi dikhaya hai
@dimalbarman44285 жыл бұрын
Sir 24 by 30 fit building sat take Kitna tmt bar lagyga ,comment please.colmin air bim mein 16 and 12 tmt use karange
@adityajoundal8500 Жыл бұрын
Yes sir 👍
@simantakumardalai81895 жыл бұрын
Bahat achha
@civilsitevisit5 жыл бұрын
keep watching brother
@Amit775005 жыл бұрын
Thank you sir Aap best me best ho sir
@civilsitevisit5 жыл бұрын
Thanks sunil keep loving 🔥
@252ranjeetrajendrashinde54 жыл бұрын
Pile ke bar rectangular shape me kaise kre
@RaviKumar-wu2rr5 жыл бұрын
Sir column ke varticale Rainforment me jogal nahi karte h but column ke lap ke liye jogal kyu krte h please reply
@anujarora44135 жыл бұрын
Brother Jo displaced bar tha usko exposed point se cut kiya fir initial alignment me hole karke another bar usme insert ki fir cut ki hui bar ko L shape deke doosri bar se weld kiya?
@sagarjadon24045 жыл бұрын
Staircase marking slope and step both please upload
@civilsitevisit5 жыл бұрын
soon brother keep watching and keep loving
@manojsahoo75795 жыл бұрын
Hlo sir good afternoon... please make a video about on details of pile foundation ....nd quantity calculation ...
@civilsitevisit5 жыл бұрын
ofcourse brother soon
@manojsahoo75795 жыл бұрын
@@civilsitevisit thank you sir
@rahultolani74854 жыл бұрын
1 more question sir, bhot baar aisa hota h site pe, jab column size or column steel jaise jaise upr jaTe h to reduce ho Jaye h, as per steel design. Eg. Column C1 (230 X 530 mm) Mei initially steel is as 12 bars of 20mm upto third storey and for fourth storey steel is reduced to 8 bars of 16 mm and column size reduced to 230 X 450 MM... In this case what is the right way of providing the steel and lap connection of the column steel...please explain. Thank you 😊!!
@sahilbanyal12324 жыл бұрын
What is the cost for rebaring?
@arvinddube13975 жыл бұрын
Sir ye bataiye if yadi collom lambai me sidha h lekin kuchh collom chaudai me ek line me nhi h to issse koi dikkat ho sakti h makan bad guniya ho gaya h to iska koi upay h ,yadi no. H to dijiye...
@civilsitevisit5 жыл бұрын
haan dikhat houfi tiling n plaster meh ...shilna padega column
@shailendradiwa84235 жыл бұрын
Sir...mere ganv ke ghar me column me yhi dikkat hua tha aaj ghar me crack aa rha h .... ab usko thik kiya ja sakta h??
@VivekKumar-qq3ol3 жыл бұрын
10 by 10 ke pillar Mein ye process kaise karenge
@surajitdas7894 жыл бұрын
Sir 230 mm niche samajh a gaya lekin upar toh 750mm dikha raha hai please ek 3d photo share kare sir
@dheerajshukla89025 жыл бұрын
Sr video editing k liye kon sa app or software use krte ho
@sfr13905 жыл бұрын
sir maine apne lower floor ke bathroom ke upar bathroom banaya hai par upar wala neeche wali deewar se 2.1/2 fit bahar hai linter pe uska weight hai kindly guide
@AkashSharma-zt7xk5 жыл бұрын
Thank you sir
@civilsitevisit5 жыл бұрын
keep watching
@zoya15205 жыл бұрын
Jo bend ho geya tha uska kya hua ??? Cut kar Diya ya phir wyse hi chor diya ????
@civilsitevisit5 жыл бұрын
cut
@vikramthakur59405 жыл бұрын
Good sir
@civilproof78365 жыл бұрын
(in video)Top bar lapping is in beam column junction....is this right or wrong???????
@civilsitevisit5 жыл бұрын
it is right praticaly but not acc. IS codee
@civilproof78365 жыл бұрын
It should be at center right???
@fasttrendiz34113 жыл бұрын
Aur usi site pe ek cornaer ka coloum ka 6 inch bahar chala gya center line, to contractor, 2 sariya hi tod diya jad m, aur wo chorke plinth bim bhi dal diya, wo bhi 9*18 k colum th uska ky kre
@sapnac3257 Жыл бұрын
Jab slab hi 125 mm ka he tab?
@wethepeople19965 жыл бұрын
But kya iss se strength kam ni hogi? Original k respect me?
@civilsitevisit5 жыл бұрын
yes ofcourse thoda farak padega
@fareedmohammed2785 жыл бұрын
20by45 main calum distance Kia Honda hai
@rajivbhowmickgkb2803 жыл бұрын
Sir plz ek video banao 🙏🙏. Ager extention rebar small hain or corrosion se ager rcc rebar ka diameter kam ho jaye to 2nd 3rd floor extention kaise kare??
@nitinpandharkar66465 жыл бұрын
Rebar embedment shall be designed for pull out capacity/force, it shall not be 230 mm. Newly embedded rebar length above concrete shall be lap length not @700
@yogeshkumar-jn5pb4 жыл бұрын
Ye to centre ka steel hai agar side ke steel me jackle aye to kya kre
@rahuldaroch6824 жыл бұрын
sir jo aap 750 bol rhe hou..uske accordingly agar columns mei bar 25 mm kaa hou toh as per is code456:2000 k hisaab se toh ban ee nai rha...lap should be 25*50=1250mm....how its possible 750mm.?????
@malharmemon60933 жыл бұрын
Sir wo lap length jo ap multiply krhe ho wo yahan kam ki nhi yahi formula hai 230 750
@amansharma3074 жыл бұрын
Hello sir If we need to add a storey to building And top slab of building dnt have any extended columns What shall we do?
@ghanshyammakwana34335 жыл бұрын
Super bro
@civilsitevisit5 жыл бұрын
Thanks brother keep watching n keep loving
@bedantadas515 Жыл бұрын
Is code ?? n point number
@myciviltechnology42504 жыл бұрын
Please also explain the type of welding because common welding is also reduce the strength of steel bars .a special welding is required called mechanical welding.
@SandeepNayak252 жыл бұрын
butt weld should do the job
@pardeepsaini58964 жыл бұрын
What happened when this problem arises at the 1st floor slab or above. I think this solution is only possible when the bars need to be fixed on footing. And what about the outer bar or the overall column reinforcement when they all displaced from their actual position. btw thanks for providing this information.
@SandeepNayak252 жыл бұрын
true... but it helped me in an old retrofitting work where work upto plinth was wrongly done .. I can easily start afresh as per the drawing from plinth
@0owje5 жыл бұрын
Thanks
@civilsitevisit5 жыл бұрын
wlcm keep watching
@kamaltoprani88605 жыл бұрын
Sir my house mistake underground Pani tank ke uper se coluam khada Kiya hai to ab kya kare
@kamaltoprani88605 жыл бұрын
Replay
@msingh925 жыл бұрын
site engineer: abe saale column bar : maaf krna gusse me idhar udhar nikal jaata hu
@civilsitevisit5 жыл бұрын
hahaha nice one bhai ❤️
@nitinpandharkar66465 жыл бұрын
Good solution for such mistake in isolate foundation is to replace it with new foundation
@civilsitevisit5 жыл бұрын
yes check new video on it
@a94501542474 жыл бұрын
Sir ye toh heavy piller k case me bataya...jab ki gher k piller 9 ya 12 inch k hote hai...uss case me shifting ko kaise correct krenge... Mere plot me kuch time pehle work hua tha ab usme sabhi piller ki sariya bend ho gyi hai... Toh usko correct kaise kiya jaye...
@alive4ffun5 жыл бұрын
When welding process will be introduced it also heat the bars and will make it hard as you said in video
@hanzalamusheerkhan82775 жыл бұрын
At place of weld always two bars are present so actual Ast is doubled, which accounts for loss in strength of steel; that's why always suitable lap length is essential, basic of lapping 🤗
@SK-ld9lu5 жыл бұрын
koi job h site engg k m pas out hu 2018 k r m delhi m hu i need a job plz hlp me..
@subhashkapoor25073 жыл бұрын
My house is constructed two storeys..with 9"*9" columns on both sides..now I want to raise another two storeys on it...can I go with similar size columns or what to do..plz guide...thanx
@mrklifeline80325 жыл бұрын
Good
@SalmanKhan-or2cz4 жыл бұрын
Sir job lagwa do khi
@civilsitevisit4 жыл бұрын
civilsitevisit.com
@upanshusharma78155 жыл бұрын
Thankyou sir
@31Rohit_k_vlogs5 жыл бұрын
What should we do if that types of mistakes comes in first floor, where the thickness of floor is 150mm. And the size of column size is 250mm x 250mm.
@civilsitevisit5 жыл бұрын
same hole 230 in column n insert steel n weld
@31Rohit_k_vlogs5 жыл бұрын
@@civilsitevisit any formula or any Thumrule for inserting of rebar like 15d , 20d Or anything else.
@ravipatel93165 жыл бұрын
@@31Rohit_k_vlogs not any formula... it's given in company's material description... it's vary for saperate material
@31Rohit_k_vlogs5 жыл бұрын
@@ravipatel9316 ok. Thanks
@saqlainsayed26415 жыл бұрын
But how to prevent this, what is the reason of this displacement
@bhardwaj_abhishek5 жыл бұрын
सर आप बीच में ties की जगह stirrup बोल रहे है जो कि गलत है इससे students को गलतफहमी हो सकता है क्यूकी कॉलम में जो रिंग बांधा जाता है उसे ties कहते हैं और beam में जो रिंग बांधा जाता है उसे stirrups कहते हैं।
@civilsitevisit5 жыл бұрын
eheheh aesa ni brother ties alag cheez hai stirrup alag
@bhardwaj_abhishek5 жыл бұрын
@@civilsitevisit ties and stirrups me difference Kya h aap hi bta dijiye qki Mai bhi diploma Civil Engineer ka student hu Aur hme Aisha hi padhaya gya hai aur kuch vdo me bhi Maine yahi dekha h jaisa ki Maine phle btaya h