Biggest mistake on construction site | Column Bar को सही करने का तरीका ?

  Рет қаралды 366,933

Civil site visit

Civil site visit

Күн бұрын

Пікірлер: 204
@neerajyaduvanshi5661
@neerajyaduvanshi5661 4 жыл бұрын
Mai already thik karwa chuka hu is mistake ko and thanx sir aapki video se mujhe bahut help milti hai ek video coasting P nikaliye puri details k sath sir pls
@mirsaif5795
@mirsaif5795 2 жыл бұрын
Sahi video banaya Bhai tum ne....
@abhishekgautam8185
@abhishekgautam8185 5 жыл бұрын
Aap bahut axe se explain krte hain... Thnk u sir
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanks brother aese he dekhte raho sekhte raho n share plz ❤️
@pranjalbaishya834
@pranjalbaishya834 5 жыл бұрын
thnks vaai.. mere site pe hua tha yeh mistake.. shttrng ka spprt hil gaya tha.. column ka top 55 mm hil gaya tha... fir maine twist kara k thik kiya.. galat tha pata tha.. pr sahi tarika aaj malum para.. ab se fichr chmicl use karunga..thnkss buddy
@civilsitevisit
@civilsitevisit 5 жыл бұрын
wlcm pranjal ❤️ keep watching
@ShadabKhan-ls4rv
@ShadabKhan-ls4rv 2 жыл бұрын
Sir you are doing great job
@adityajoundal8500
@adityajoundal8500 Жыл бұрын
Knowledgeable Video sir
@mirsaif5795
@mirsaif5795 2 жыл бұрын
Yeh kaisi thanks bolna samaj nahi Ara lekin bohat shukriya is video se kai sare logon ku bohat badi madad hogayee...
@vaibhavchavan6040
@vaibhavchavan6040 5 жыл бұрын
Thank u sir. very helpful video for site engineer.
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanks brother please shate
@awaisahmad8935
@awaisahmad8935 2 жыл бұрын
I learned best column correction method from this video, great job sir
@syedmahmood2372
@syedmahmood2372 4 жыл бұрын
This video was really very helpful Sir
@adarshallkindsgame8988
@adarshallkindsgame8988 5 жыл бұрын
very important information Sir ji thanks
@sarthakmohapatra3738
@sarthakmohapatra3738 4 жыл бұрын
Excellent video sir . Thnx a lot
@fasttrendiz3411
@fasttrendiz3411 3 жыл бұрын
Sir foundation colum 9*18 ka tha, 5 inch jaggal kiya h, dusre ki jagah m chala gya tha , coloum uspe plinth bim bhi dal diya, ab ky kre ,
@hollywoodexplosivetrailers8711
@hollywoodexplosivetrailers8711 9 ай бұрын
Mere isme 2 inch ka dal diya joggle
@ItsAditya_xyz
@ItsAditya_xyz 7 ай бұрын
Hey, it's been 3 years. Did you have any troubles due to this?
@shouryabikashjena7834
@shouryabikashjena7834 4 жыл бұрын
Sir agar aisa chhat banane ke baad hua to kya karu.....?please reply
@tripuritech4627
@tripuritech4627 Ай бұрын
Kaunsa IS code ka reference hai please reply?
@ramchandrashrivastava3639
@ramchandrashrivastava3639 5 жыл бұрын
Very very useful video.
@priyankapanche8636
@priyankapanche8636 2 жыл бұрын
Best idea sir
@mdreyazshaikh7241
@mdreyazshaikh7241 5 жыл бұрын
Bahut achha sir jii
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanks bhai
@sunitaprasad2724
@sunitaprasad2724 4 жыл бұрын
Very nice Sir Thank you so much
@awaisahmad8935
@awaisahmad8935 3 жыл бұрын
I faced this situation and corrected with the help of your video, thanks a lot sir, U r wonderful
@ImranKhan-nu2tt
@ImranKhan-nu2tt 4 жыл бұрын
Good message 👍
@civilsitevisit
@civilsitevisit 4 жыл бұрын
thanks brother
@GurpreetSingh-pj4vk
@GurpreetSingh-pj4vk 4 жыл бұрын
Good
@ashutoshupadhyay5928
@ashutoshupadhyay5928 5 жыл бұрын
Will you please let us know from which IS code or ASTM you are suggesting it
@ankitsingh-hg4cm
@ankitsingh-hg4cm 5 жыл бұрын
Very very good sir Expecting more like this Thank you
@Kshitijsingh91
@Kshitijsingh91 3 жыл бұрын
Same work ghar k building me v karna chahiye kya
@turtlebrains
@turtlebrains 4 жыл бұрын
Kya ham chhat se naya structure taiyar kar skte hai
@Iitgstr1
@Iitgstr1 4 жыл бұрын
Nice information 👌 Brother, thanks
@salimjave1834
@salimjave1834 4 жыл бұрын
Best video sir
@civilpro9537
@civilpro9537 5 жыл бұрын
Sir jo misplaced ho gaya hai ushe cut karke hatana hai kay ?
@civilsitevisit
@civilsitevisit 5 жыл бұрын
haan jo misplace ho jyta hai usko htana hota hai
@civilpro9537
@civilpro9537 5 жыл бұрын
instead of welding can we tight with binding wire sir ?
@pranjalbaishya834
@pranjalbaishya834 5 жыл бұрын
wire se v sayad kr sakte ho.. lekin mazbooti utna nahi milega jitna welding main milega..
@dhingranitish
@dhingranitish 3 жыл бұрын
Nice content
@nitinpandharkar6646
@nitinpandharkar6646 5 жыл бұрын
What is your suggestion for rebar which are not in position/need to be jackled. Did you cut these rebar? Or kept as it is in column
@SandeepNayak25
@SandeepNayak25 2 жыл бұрын
just cut them
@muhammadharisbacha3466
@muhammadharisbacha3466 4 жыл бұрын
Sir tile analysis Kai barai main vedieo bana dai
@zetchalama4112
@zetchalama4112 3 жыл бұрын
Can same method be done if column mistakes in on first floor
@sonalibahuguna1945
@sonalibahuguna1945 2 жыл бұрын
Out of 16 columns, 5 Columne are misplaced by 2 to 5 inches.. plinth beam is already casted. What should be correction for this mistake ?
@perfectstranger2845
@perfectstranger2845 2 ай бұрын
How did you fix it? I’m having same problem . I think you used rebar chemical ?
@shahidiyasir4396
@shahidiyasir4396 5 жыл бұрын
Bht Sahi...
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanks bhai
@Rajeevkumar-qb1rj
@Rajeevkumar-qb1rj Жыл бұрын
Usko position change karne ke liye Kitna inch jogal de sakte
@sajidchoudhary3464
@sajidchoudhary3464 3 жыл бұрын
Sir yei to apne 230 kai grout kr leya footing k base pr sai lken slab pr sai colume out ho jaye to 230mm kai grout kaise hoga slab ki to thicknes hi 150mm ki hote hai waha kaise kre sir reply plz
@viralintwala4249
@viralintwala4249 Жыл бұрын
Which IS code allow this method ?
@UmeshKumar-fm1qp
@UmeshKumar-fm1qp 4 жыл бұрын
very good
@prashantkumar-tg1wv
@prashantkumar-tg1wv 3 жыл бұрын
Super sir
@CivilSiteadda10
@CivilSiteadda10 5 жыл бұрын
Sir aap videos edit ke liye kon sa app use krte ho
@amitthakur8629
@amitthakur8629 5 жыл бұрын
Sir agar chat par first ya second floor me hua hai to bhi same rule rahega kya
@Waseemakram-fd3oe
@Waseemakram-fd3oe 5 жыл бұрын
thank you sir aap ni zabardase video ke hai sir
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanks waseem keep watching
@chennareddyindla2349
@chennareddyindla2349 4 жыл бұрын
Good.
@sachinshrivastav517
@sachinshrivastav517 4 жыл бұрын
Hilti and fisher grouting service available
@civilsitevisit
@civilsitevisit 4 жыл бұрын
okeah
@shivrgpandeya4679
@shivrgpandeya4679 5 жыл бұрын
Sir ji, Steel cut kar denge but niche se aadha steel se match kaha ho payega Jo 230mm niche dril karke dall rhe vah concrete pr rest krega n niche steel k tuch me kaise rahega
@civilsitevisit
@civilsitevisit 5 жыл бұрын
match ni brother ....bs insert n grout
@shivrgpandeya4679
@shivrgpandeya4679 5 жыл бұрын
Ha vahi, confusion ye h ki jo steel niche se continue aarha uska end karke fir dusra steel dal rhe,us continue steel se link khatm hojarha n, ye doubt h mera
@vikasgawai9310
@vikasgawai9310 5 жыл бұрын
Same doubt for me...
@ravipatel9316
@ravipatel9316 5 жыл бұрын
Continuity will be break... we're going for newer steel with method of Rebaring... Yes, it's not as per design for spacing of vertical bars , but it's better option over jackiling of bars...
@pranjalbaishya834
@pranjalbaishya834 5 жыл бұрын
continuety brek hoga.. sahi hai.. par twist karke continue krne se grout krna bettr hai...
@harshraj7307
@harshraj7307 2 жыл бұрын
Bhaiyaa mere ghar ise trah dhalai ho gya 3 room ek hall sara room badguniya nikal gya stairs be tedha ho gya ab second floor aisa na iske lea kya ho seckta hai ya kuch nahi ho payega
@sachinparmar2820
@sachinparmar2820 5 жыл бұрын
Lekin sir jo sariya out ho gya usko to die marke column ke andar to lana pdega na. Ya fir out huwi bar ko cut kr lee
@pramodtiwari9198
@pramodtiwari9198 5 жыл бұрын
Kya ye tarika pwd,cpwd etc Mai manya hoga?
@a9450154247
@a9450154247 4 жыл бұрын
Very impressive sir... Chote plot ya structure k liye piller itne heavy nhi hote h... Aur 4bar pillar me h aur 4 hole kr k ye process krna impossible hoga?? Waha kaise kare isko???
@tanweerabbas6628
@tanweerabbas6628 5 жыл бұрын
Please upload a video on substation
@civilhunt1041
@civilhunt1041 5 жыл бұрын
sir outer peripheral ka rod agar out of actual position se nikal gaya toh kaise Karna hai... apne toh andar wala ka hi dikhaya hai
@dimalbarman4428
@dimalbarman4428 5 жыл бұрын
Sir 24 by 30 fit building sat take Kitna tmt bar lagyga ,comment please.colmin air bim mein 16 and 12 tmt use karange
@adityajoundal8500
@adityajoundal8500 Жыл бұрын
Yes sir 👍
@simantakumardalai8189
@simantakumardalai8189 5 жыл бұрын
Bahat achha
@civilsitevisit
@civilsitevisit 5 жыл бұрын
keep watching brother
@Amit77500
@Amit77500 5 жыл бұрын
Thank you sir Aap best me best ho sir
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanks sunil keep loving 🔥
@252ranjeetrajendrashinde5
@252ranjeetrajendrashinde5 4 жыл бұрын
Pile ke bar rectangular shape me kaise kre
@RaviKumar-wu2rr
@RaviKumar-wu2rr 5 жыл бұрын
Sir column ke varticale Rainforment me jogal nahi karte h but column ke lap ke liye jogal kyu krte h please reply
@anujarora4413
@anujarora4413 5 жыл бұрын
Brother Jo displaced bar tha usko exposed point se cut kiya fir initial alignment me hole karke another bar usme insert ki fir cut ki hui bar ko L shape deke doosri bar se weld kiya?
@sagarjadon2404
@sagarjadon2404 5 жыл бұрын
Staircase marking slope and step both please upload
@civilsitevisit
@civilsitevisit 5 жыл бұрын
soon brother keep watching and keep loving
@manojsahoo7579
@manojsahoo7579 5 жыл бұрын
Hlo sir good afternoon... please make a video about on details of pile foundation ....nd quantity calculation ...
@civilsitevisit
@civilsitevisit 5 жыл бұрын
ofcourse brother soon
@manojsahoo7579
@manojsahoo7579 5 жыл бұрын
@@civilsitevisit thank you sir
@rahultolani7485
@rahultolani7485 4 жыл бұрын
1 more question sir, bhot baar aisa hota h site pe, jab column size or column steel jaise jaise upr jaTe h to reduce ho Jaye h, as per steel design. Eg. Column C1 (230 X 530 mm) Mei initially steel is as 12 bars of 20mm upto third storey and for fourth storey steel is reduced to 8 bars of 16 mm and column size reduced to 230 X 450 MM... In this case what is the right way of providing the steel and lap connection of the column steel...please explain. Thank you 😊!!
@sahilbanyal1232
@sahilbanyal1232 4 жыл бұрын
What is the cost for rebaring?
@arvinddube1397
@arvinddube1397 5 жыл бұрын
Sir ye bataiye if yadi collom lambai me sidha h lekin kuchh collom chaudai me ek line me nhi h to issse koi dikkat ho sakti h makan bad guniya ho gaya h to iska koi upay h ,yadi no. H to dijiye...
@civilsitevisit
@civilsitevisit 5 жыл бұрын
haan dikhat houfi tiling n plaster meh ...shilna padega column
@shailendradiwa8423
@shailendradiwa8423 5 жыл бұрын
Sir...mere ganv ke ghar me column me yhi dikkat hua tha aaj ghar me crack aa rha h .... ab usko thik kiya ja sakta h??
@VivekKumar-qq3ol
@VivekKumar-qq3ol 3 жыл бұрын
10 by 10 ke pillar Mein ye process kaise karenge
@surajitdas789
@surajitdas789 4 жыл бұрын
Sir 230 mm niche samajh a gaya lekin upar toh 750mm dikha raha hai please ek 3d photo share kare sir
@dheerajshukla8902
@dheerajshukla8902 5 жыл бұрын
Sr video editing k liye kon sa app or software use krte ho
@sfr1390
@sfr1390 5 жыл бұрын
sir maine apne lower floor ke bathroom ke upar bathroom banaya hai par upar wala neeche wali deewar se 2.1/2 fit bahar hai linter pe uska weight hai kindly guide
@AkashSharma-zt7xk
@AkashSharma-zt7xk 5 жыл бұрын
Thank you sir
@civilsitevisit
@civilsitevisit 5 жыл бұрын
keep watching
@zoya1520
@zoya1520 5 жыл бұрын
Jo bend ho geya tha uska kya hua ??? Cut kar Diya ya phir wyse hi chor diya ????
@civilsitevisit
@civilsitevisit 5 жыл бұрын
cut
@vikramthakur5940
@vikramthakur5940 5 жыл бұрын
Good sir
@civilproof7836
@civilproof7836 5 жыл бұрын
(in video)Top bar lapping is in beam column junction....is this right or wrong???????
@civilsitevisit
@civilsitevisit 5 жыл бұрын
it is right praticaly but not acc. IS codee
@civilproof7836
@civilproof7836 5 жыл бұрын
It should be at center right???
@fasttrendiz3411
@fasttrendiz3411 3 жыл бұрын
Aur usi site pe ek cornaer ka coloum ka 6 inch bahar chala gya center line, to contractor, 2 sariya hi tod diya jad m, aur wo chorke plinth bim bhi dal diya, wo bhi 9*18 k colum th uska ky kre
@sapnac3257
@sapnac3257 Жыл бұрын
Jab slab hi 125 mm ka he tab?
@wethepeople1996
@wethepeople1996 5 жыл бұрын
But kya iss se strength kam ni hogi? Original k respect me?
@civilsitevisit
@civilsitevisit 5 жыл бұрын
yes ofcourse thoda farak padega
@fareedmohammed278
@fareedmohammed278 5 жыл бұрын
20by45 main calum distance Kia Honda hai
@rajivbhowmickgkb280
@rajivbhowmickgkb280 3 жыл бұрын
Sir plz ek video banao 🙏🙏. Ager extention rebar small hain or corrosion se ager rcc rebar ka diameter kam ho jaye to 2nd 3rd floor extention kaise kare??
@nitinpandharkar6646
@nitinpandharkar6646 5 жыл бұрын
Rebar embedment shall be designed for pull out capacity/force, it shall not be 230 mm. Newly embedded rebar length above concrete shall be lap length not @700
@yogeshkumar-jn5pb
@yogeshkumar-jn5pb 4 жыл бұрын
Ye to centre ka steel hai agar side ke steel me jackle aye to kya kre
@rahuldaroch682
@rahuldaroch682 4 жыл бұрын
sir jo aap 750 bol rhe hou..uske accordingly agar columns mei bar 25 mm kaa hou toh as per is code456:2000 k hisaab se toh ban ee nai rha...lap should be 25*50=1250mm....how its possible 750mm.?????
@malharmemon6093
@malharmemon6093 3 жыл бұрын
Sir wo lap length jo ap multiply krhe ho wo yahan kam ki nhi yahi formula hai 230 750
@amansharma307
@amansharma307 4 жыл бұрын
Hello sir If we need to add a storey to building And top slab of building dnt have any extended columns What shall we do?
@ghanshyammakwana3433
@ghanshyammakwana3433 5 жыл бұрын
Super bro
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanks brother keep watching n keep loving
@bedantadas515
@bedantadas515 Жыл бұрын
Is code ?? n point number
@myciviltechnology4250
@myciviltechnology4250 4 жыл бұрын
Please also explain the type of welding because common welding is also reduce the strength of steel bars .a special welding is required called mechanical welding.
@SandeepNayak25
@SandeepNayak25 2 жыл бұрын
butt weld should do the job
@pardeepsaini5896
@pardeepsaini5896 4 жыл бұрын
What happened when this problem arises at the 1st floor slab or above. I think this solution is only possible when the bars need to be fixed on footing. And what about the outer bar or the overall column reinforcement when they all displaced from their actual position. btw thanks for providing this information.
@SandeepNayak25
@SandeepNayak25 2 жыл бұрын
true... but it helped me in an old retrofitting work where work upto plinth was wrongly done .. I can easily start afresh as per the drawing from plinth
@0owje
@0owje 5 жыл бұрын
Thanks
@civilsitevisit
@civilsitevisit 5 жыл бұрын
wlcm keep watching
@kamaltoprani8860
@kamaltoprani8860 5 жыл бұрын
Sir my house mistake underground Pani tank ke uper se coluam khada Kiya hai to ab kya kare
@kamaltoprani8860
@kamaltoprani8860 5 жыл бұрын
Replay
@msingh92
@msingh92 5 жыл бұрын
site engineer: abe saale column bar : maaf krna gusse me idhar udhar nikal jaata hu
@civilsitevisit
@civilsitevisit 5 жыл бұрын
hahaha nice one bhai ❤️
@nitinpandharkar6646
@nitinpandharkar6646 5 жыл бұрын
Good solution for such mistake in isolate foundation is to replace it with new foundation
@civilsitevisit
@civilsitevisit 5 жыл бұрын
yes check new video on it
@a9450154247
@a9450154247 4 жыл бұрын
Sir ye toh heavy piller k case me bataya...jab ki gher k piller 9 ya 12 inch k hote hai...uss case me shifting ko kaise correct krenge... Mere plot me kuch time pehle work hua tha ab usme sabhi piller ki sariya bend ho gyi hai... Toh usko correct kaise kiya jaye...
@alive4ffun
@alive4ffun 5 жыл бұрын
When welding process will be introduced it also heat the bars and will make it hard as you said in video
@hanzalamusheerkhan8277
@hanzalamusheerkhan8277 5 жыл бұрын
At place of weld always two bars are present so actual Ast is doubled, which accounts for loss in strength of steel; that's why always suitable lap length is essential, basic of lapping 🤗
@SK-ld9lu
@SK-ld9lu 5 жыл бұрын
koi job h site engg k m pas out hu 2018 k r m delhi m hu i need a job plz hlp me..
@subhashkapoor2507
@subhashkapoor2507 3 жыл бұрын
My house is constructed two storeys..with 9"*9" columns on both sides..now I want to raise another two storeys on it...can I go with similar size columns or what to do..plz guide...thanx
@mrklifeline8032
@mrklifeline8032 5 жыл бұрын
Good
@SalmanKhan-or2cz
@SalmanKhan-or2cz 4 жыл бұрын
Sir job lagwa do khi
@civilsitevisit
@civilsitevisit 4 жыл бұрын
civilsitevisit.com
@upanshusharma7815
@upanshusharma7815 5 жыл бұрын
Thankyou sir
@31Rohit_k_vlogs
@31Rohit_k_vlogs 5 жыл бұрын
What should we do if that types of mistakes comes in first floor, where the thickness of floor is 150mm. And the size of column size is 250mm x 250mm.
@civilsitevisit
@civilsitevisit 5 жыл бұрын
same hole 230 in column n insert steel n weld
@31Rohit_k_vlogs
@31Rohit_k_vlogs 5 жыл бұрын
@@civilsitevisit any formula or any Thumrule for inserting of rebar like 15d , 20d Or anything else.
@ravipatel9316
@ravipatel9316 5 жыл бұрын
@@31Rohit_k_vlogs not any formula... it's given in company's material description... it's vary for saperate material
@31Rohit_k_vlogs
@31Rohit_k_vlogs 5 жыл бұрын
@@ravipatel9316 ok. Thanks
@saqlainsayed2641
@saqlainsayed2641 5 жыл бұрын
But how to prevent this, what is the reason of this displacement
@bhardwaj_abhishek
@bhardwaj_abhishek 5 жыл бұрын
सर आप बीच में ties की जगह stirrup बोल रहे है जो कि गलत है इससे students को गलतफहमी हो सकता है क्यूकी कॉलम में जो रिंग बांधा जाता है उसे ties कहते हैं और beam में जो रिंग बांधा जाता है उसे stirrups कहते हैं।
@civilsitevisit
@civilsitevisit 5 жыл бұрын
eheheh aesa ni brother ties alag cheez hai stirrup alag
@bhardwaj_abhishek
@bhardwaj_abhishek 5 жыл бұрын
@@civilsitevisit ties and stirrups me difference Kya h aap hi bta dijiye qki Mai bhi diploma Civil Engineer ka student hu Aur hme Aisha hi padhaya gya hai aur kuch vdo me bhi Maine yahi dekha h jaisa ki Maine phle btaya h
@sridharsahoo8159
@sridharsahoo8159 5 жыл бұрын
Right he bro
@civilsitevisit
@civilsitevisit 5 жыл бұрын
Thanke brother
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 958 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
Welding, Lapping, Coupling of Reinforcement in Column and Slab - Which is Best
7:47
Learning Civil Technology
Рет қаралды 2,4 МЛН
Парадокс ригеля и стропил
9:09
GetAClass - Физика в опытах и экспериментах
Рет қаралды 1,5 МЛН
Selecting Type of Foundation from Type of Soil?
6:33
Engineering Motive
Рет қаралды 101 М.
Understand the Arrangement of Reinforcement |Why L/3 L/4 0.25L 0.3L | Why Top Extra Why Bottom Extra
15:16
Combined One Way Slab and Two Way Slab (First Way)
19:14
AK Skills & Solutions
Рет қаралды 134 М.
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН