Keep going sir...... Ur explanation is simply awesome each words are so clear vry simple and vry powerful.... Please include more routine works.....!
@leckyjake4 жыл бұрын
Thank you for your wonderful comment
@stanislavnikov55944 жыл бұрын
Hello,make a video for boiler
@edwardannor29423 жыл бұрын
Thanks for sharing sir. If possible, please try to do one on the shaft generator system working together with a synchronous condenser.
@MyleneSanchez242 ай бұрын
leckyjake salamat sa contribution mo saaming mga seafarers
@denis_artemov4 жыл бұрын
We highly appreciate your endeavors! Keep doing your useful videos!
@BrettCraft9 ай бұрын
Great video. I guess if the normal power is intermittent then one might get into trouble if the emergency power is shut off too soon. Then you would have to wait another 45 seconds for power.
@ChandanaPriyantha-pq3uv6 ай бұрын
The lesson is important,mechanical,eletro and controlling with generator.I interest the video sir
@high47022 жыл бұрын
You are awesome!!!! The best man on KZbin who explains electrical enginere work on ship
@michaelpizza9429 ай бұрын
Great video , I’m sure this will be taken down soon , because of the Balitmore incident. Wouldn’t want people to know the truth . I always thought they had back up systems on these ships .
@fredsalter19153 жыл бұрын
Filipino guys are so cool!
@andreyrybak50514 жыл бұрын
45 seconds because according to Solas steering gear power to be restored .As I recall as well . May be mistaken 😛😉 Thanks good video
@thewanderer32822 жыл бұрын
Yes, it should come on load in 45 seconds, it gives enough time for your stby Gen to come on load if it's on auto, if it's not that's when emergency Gen will come on load.
@25denzil4 жыл бұрын
Beautifully explained 👌🏻
@ronrosario67634 жыл бұрын
Awesome Senior thanks for sharing ur experience
@leckyjake4 жыл бұрын
Thank you for your support
@ikounojo47732 жыл бұрын
Sory sir, I'm try adj.The AVR. Affer that, still unstable voltage & hz, of generator
@verhillovalakay53933 жыл бұрын
ok vidio mo sir,sa sunod na vlog mo sana ay tungkol naman sa interview o ang mga tanong sa pag aply bilang generator technician hehehe
@leckyjake3 жыл бұрын
Thank you sa support
@ashikmaruf54814 жыл бұрын
Love u man valuable information
@sudhakarcvcv17768 ай бұрын
Well explained about black out.... thank you..
@rahurtadoa3 жыл бұрын
Canales así hacen mucha falta un cordial saludo y Muchas gracias por su tiempo en compartir conocimiento. Channels like this need a cordial greeting and Thank you very much for your time in sharing knowledge.
@MsPinks0073 жыл бұрын
Lecky sir you are outstanding.. please keep making these type of practical informative Videos..Namste 🙏
@humanbeing409710 ай бұрын
Very helpful please keep it up.
@hirzandany42553 жыл бұрын
Nice video sir, but would you like to share vassel tour ?
@williamsitton4 жыл бұрын
You should make a patreon so we can support you even further! or drop some merch!!!!
@jamber007 Жыл бұрын
How do you restore back to normal conditions. Coming from your Emergency Switchboard to your Main Switchboard?
@arunnair41304 жыл бұрын
Very well explained..👍🏻👍🏻
@nolitobalboa67132 жыл бұрын
Emergency steering test .please explain.
@atafavour21203 жыл бұрын
Pls you didn't make mention of the panel we can switch from battery to hydraulic manually.. because I know the other panel to switch from the auto to the manual firstly is the bustie panel
@harrissaddam51883 жыл бұрын
1st time I saw hydraulic crack, in my experience of previous vessels all use spring crank 😅
@Txepetxcc3 жыл бұрын
Can you explain how many kW does each subsystem use ? 480kW for only critical loads sounds HUGE !
@faizalraazy91 Жыл бұрын
Great explanation
@srivatsavmattaparthi49154 жыл бұрын
Hi sir,Make a video on boiler operations
@codesAfri4 жыл бұрын
Hey, can you show us how to block the key pad on Carrier and on Dainkin please?
@ronrosario67633 жыл бұрын
Yo bro good evening can you show us the vedio how you put load for testing the performance of Generators once it's done overhauling. Like they need to test performance load test so I need how u keep.load on generator 40%,or 50%,60%depends how service engineer asks so can u show us how to keep this load thanks a lot
@suryaapov73404 жыл бұрын
Excellent 👍
@chetanjungi50772 жыл бұрын
Hi Mr. Lecky, Thanks for your all Videos Regarding Maintenance of Refrigeration, Mechanical & Electrical, thanks a lot for giving us nice knowledge of it. we can easily understand your English speech. i want know that in your video about "BLACK OUT AND EMERGENCY GENERATOR, THINGS YOU NEED TO DO " 4 Dec 2020 you told that the emergency Generator capacity 480KW. ok. i this in saw video, as per my knowledge, The Generator is CATERPILLAR make 3406 model and Capacity of this DG may be 320KVA to 380 KVA in 50Hz. may be Different in 60Hz (1800RPM) but saws model is 3406 (6 Cylinder in line) and as per your speech in Video 480 kw. Mean 3412 OR 600 KVA DG of CAT. Pls check it. Thanks. Chetan Jungi ( Porbandar - Gujarat - INDIA)
@johncantrell6143 жыл бұрын
Good stuff, thanks for sharing!
@232СтадникРома Жыл бұрын
Very good video. But i still not understand: what actions should do when EDG is already running, and while this moment you was started the DG, is it posible to synchronize them? Or what should i do when the main generator is already working?
@leonardothevinchi3 ай бұрын
EDG nd DG can never synchronize. Once DG takes load, EDG will cut off
@ziko69892 жыл бұрын
super sir. thank you.
@prasadp7682 жыл бұрын
How to make good knowledge in electrical?
@carlamahquel55974 жыл бұрын
How can I learn to repair container reefers???
@seth29asigadi253 жыл бұрын
Sir salamat sa mga videos mo. Marami din akong natutunan. I know iba talaga sa actual at by watching your videos only pero atleast may insight na ako if ever maka sampa na ako. Hindi ka naba nag interisland sir dati? Sa 1st ship mo?
@pothinetimohan42793 жыл бұрын
Good tockking to you sir.deep explain super sir
@cyrildelacruzjr43653 жыл бұрын
Thanks sir keep safe 🙏 god BLESs 🙏
@ibadbinabrar2252 Жыл бұрын
Why there is ebonite rod in MSB what is the porpose
@junmaromega27474 жыл бұрын
thank you idol leckyjake..
@AbdulKhan-wu7oy2 жыл бұрын
Best video ☺️
@luiszamora36852 жыл бұрын
I'm going to add that you guys don't try messing with this if your not experienced or have knowledge of what equipment your putting your hands on. There is serious voltage behind this that could kill you , destroy equipment ,and operation of the building . It also against Osha requirements without proper ppe gear on.
@rakibhasan-lm5bd Жыл бұрын
very informative sir
@MaxKharevsky4 ай бұрын
Very good
@allawanmusa48732 жыл бұрын
Thank you!
@leckyjake2 жыл бұрын
thank you for watching
@archive99943 жыл бұрын
Thank you for sharing your videos
@harshavardhangoud3726 Жыл бұрын
Sir how much is your eye sight? As your wear spects is it possible to hold a job as an ETO?
@joefajardojr39024 жыл бұрын
After you start locally and switch to auto all the load connected to ESB have a supply from EG is it correct ? Then the bus tie open to MSB?
@milanljuba75633 жыл бұрын
If i understood your question that is not the case. If you start eme genset locally (manual start) and flip the esb switch to auto nothing will happen. But if you press test on esb you will actually do a short black out on essential consumers and you need at least to inform the bridge. That will happen because the bus tie breaker will open prior the gcb will close (interlock). You dont want a relatively small diesel engine to feed power back to MSB or to go parallel with other gensets that are actually connected to MSB at time when you do a test.
@gabornerimar20944 жыл бұрын
Thanks you
@mr__xs___2437 Жыл бұрын
Thala always rocking star thala 🎉🎉🎉❤
@kahar20114 жыл бұрын
Thank for your sharing..
@rodeldurban45344 жыл бұрын
Sir yung on load test po ba ay yung icconect mu yung generator s load after imanual start like by battery or hydraulic? Thanks sir
@thompson.j26312 жыл бұрын
Where is to test emergency gen routine? At sea or Port
@RajinderKumar-fm5yu Жыл бұрын
Thanks sir ji
@sailing_dragon14 жыл бұрын
Thank you
@durham2220003 жыл бұрын
salamat from romania with love
@leckyjake3 жыл бұрын
Thank you
@MM-uz7gn4 жыл бұрын
I think we need a change of music lecky!
@kavenvincentperez83044 жыл бұрын
Can you make a video. For how to work emergency generator if incase blackout work in automatic(or test). and if it the main generator is back to normal. It is automatically turn off the emergency generator??? Hanep ang hirap kaya mag english hahahaha
@harotaro10673 жыл бұрын
To test Auto start and auto load in, just break the breaker supply to ESB from MSB..
@mikesolo79934 жыл бұрын
When you mention about not doing an on-load test in coastal waters, does that mean that either during a switching operation or after a main switchboard power failure, everything on emergency power dies for 45 seconds, or is there some sort of battery backup for critical systems?
@johnndukatasie99833 жыл бұрын
One there are usually so much traffic in coastal waters (due to many ships), therefore alot of maneuvering is required. Secondly, it is very unsafe. You see, during onload tests, some essential loads on the emergency generator switchboard are in manual operational modes. Now, imagine a case where during a heavy traffic in a coastal water were manual steering is mostly required and there is a blackout while an onload test is done. What will happen? Collision, grounding etc. Note that, a blackout in this context according to the PMS, is when other ship's redundant main generator(s) do not run/start automatically.
@johnndukatasie99833 жыл бұрын
To give answer to the 2nd question; on emergency generator automatic mode, everything on the emergency generator runs automatically within 45seconds if a blackout occurs
@atinderpalsingh31063 жыл бұрын
Very nice sir
@dilipsangada66914 жыл бұрын
Good morning sir from india
@etir43 жыл бұрын
thanks !
@ksantostitanos4 жыл бұрын
What voltage on MSB? 6,6 kV? Or 0,4 kV?
@charachara15033 жыл бұрын
Thanks sir
@leckyjake3 жыл бұрын
👍👍👍
@hopeforthefuture82249 ай бұрын
If it had a backup generator, which by rule should come on automatically within 45 seconds, then why didn't they use the rudder to straighten the ship. 0:00 6 to 7 mile ph maybe lower as they had just dropped anchor. It would slow them down, generator should have been on by then so they could correct course. Or was it not working, Two engines not working is highly suspicious, Could be sabotage. Who wanted that bridge torn down, who could profit if a bridge needs rebuilding, Gotta ask with so many greedy people in the world, middle of the night, no one on bridge but a few inconsequential workers and police at both ends to stop traffic because of a few workers fixing potholes in many peoples view in elite world workers are inconsequential, how convenient.
@bt96045 ай бұрын
NTSB Is investigating. Don't you have belief in US law enforcement system
@riazuddin3684 Жыл бұрын
❤❤❤❤
@arwa19694 жыл бұрын
Dear sir What grease used for medium voltage breaker and what points greasing
@akbarmaidina6585 Жыл бұрын
👍
@hopeforthefuture82249 ай бұрын
There goes our money, All these friggin theives will be overbidding every part of rebuilding bridge with promises to give big donations back to who gives them the overpriced job, such corruption today.
@Sdfghjiy3 жыл бұрын
You are diamond
@cirilopino18713 жыл бұрын
nice vlog your new follower remollo d vlogger
@MrGgambini4 жыл бұрын
Hi Jake, how are you ? How can I contact with you ? Un email, linkind. Thanks