Hi! For this calculation of boost converter. Is this also applicable for PV grid connected three phase inverter with boost?
@Aziz07-e6p Жыл бұрын
I want to ask if Vin changes, does Vout also change? for example, if the Vin of the PV changes according to the irradiance and the temperature of the Vout Boost converter it will stabilize at the desired voltage or change according to the Vin of the PV. and one more thing I ask is that because Vin VP changes regarding filling inductor and capacitor values in the boost converter, should we use which Vin value, is Vin the highest or should we take the average?
@bakarow16 жыл бұрын
why Vout is not 48V in the simulation results? was it because the part you have shown was the transient part of the waveform?
@dhriyyefmohammed95215 жыл бұрын
same question !!
@nakiguler5 жыл бұрын
@@dhriyyefmohammed9521, The video shows only boost converter design. The 48V is selected as an example. Boost converter control is another issue. I may make a video to show it. But in this model, if you change the Pulse Width in the Pulse Generator, the output voltage will change. For ex., instead of "D", I selected 48 and the output voltage is around 48V. Could you please check it?
@drlerkan3 жыл бұрын
teşekkür ederim.
@bilalanwar1495 жыл бұрын
hi, how can we decrease the output voltage ripple if we have a large? please, thanks in advance
@nakiguler5 жыл бұрын
Voltage ripple on ac side is depend on the filter. You can try increase ac capacitance at the output. If it need too big capacitance please increase inductance. You will find better values for these.
@priyankagupta36354 жыл бұрын
Where u take all parameters ( values) I mean which paper u take all values.can u provide paper
@tokatburak15 жыл бұрын
Hocam iyi günler mail adresinizi alabilir miyim ?
@nakiguler5 жыл бұрын
İyi günler resmi web sitesinde bulabilirsin. websitem.gazi.edu.tr/site/gulern/contact
@AbdulAhad-gd6gl5 жыл бұрын
I used Vin_min=273V, Vout=500V, power=100KW, fs=5K, and n=0.9 but the output current ripple is too much like way too much. is there any issue with my calculations? can you help please! I am making a simulation for a microgrid of 100KW
@nakiguler5 жыл бұрын
I simulated the model by the direction of your parameters. The output current ripple is less than 2A. It approximately 1%. If it is not acceptable for your system, please try to change the "dv_persent" parameter in the video. Because it defines the output voltage ripple. If you select fewer values than 1%, the capacitance will increase but the ripple will decrease.
@AbdulAhad-gd6gl5 жыл бұрын
@@nakiguler thanks for the reply sir, another thing is in the video there is written to take I_ripple from 20-40% of I_out than how did you take 0.4 in the calculation?
@nakiguler5 жыл бұрын
@@AbdulAhad-gd6gl, You're welcome. It can be said, as the allowed ripple factor for input current. It is for low power systems. When you decrease it, you will see the inductor current ripple will decrease. Because inductance will increase.
@AbdulAhad-gd6gl5 жыл бұрын
@@nakiguler thanks for the help
@generaljager3101 Жыл бұрын
@@AbdulAhad-gd6gl hello, from where you got the vin min and vout for pv?
@kishorekumar-pe7mj7 жыл бұрын
calculated values y ? differ from simulation value??
@nakiguler7 жыл бұрын
kishore kumar I don't calculate y value?
@kishorekumar-pe7mj7 жыл бұрын
Naki GÜLER sorry not y sir..."why"??
@jfaycel64467 жыл бұрын
please have you a vidéo for Buck Converter Parameter Calculation
@nakiguler7 жыл бұрын
Faycel Jamaaoui Ok. I will share video for buck converter parameters.