Unfortunately this is one is doomed to become an archive; zoomlock is the future :\
@eugeneeugene3313 Жыл бұрын
Wow, just wow. The guy is super professional!
@keithjordan5688 Жыл бұрын
I’m always learning something new. I’ve been brazing for around two years now and didn’t know you can braze dissimilar metals.
@armaletalia3254 Жыл бұрын
Always appreciate free knowledge. Thank you.
@MegaManGabe Жыл бұрын
I’m just starting my career in HVAC, and these videos are very helpful. So thank you!👍🏼
@courtney2878 Жыл бұрын
Wish I found this lesson 3 days ago as I just finished my first brazing project. Insanely satisfying process lol.
@jproper Жыл бұрын
I'm a 10 year tech and just popped in to see the tips. Good video as always🤘
@dr00andrew Жыл бұрын
Brazing is easily the most satisfying part of the job. Nothing like getting a nice clean joint all the way around with a nice crown filling in the edge. Ive also found that placing an inspection mirror underneath the suction line service valve while brazing ensures you fill the entire joint the 1st time around. Since you cant see underneath when brazing, the mirror allows you to see you have filled in the area you cannot see with your eyes. Then you can move around and get the spots you can see
@La2venida Жыл бұрын
What tip size you use and pressures
@winstagram178511 ай бұрын
Great tip!
@salehfarman90546 ай бұрын
This guy is super professional! Thank you so much
@HermanMeyers-k4x3 ай бұрын
Small wet rags around each tube on evap coul and on txv's pull caps and scrader cores out. Rap driers close to drier body. Make sure flame never hits the txv power head . Always braze the suction first. Purging is good on new hard drawn pipe if you can't put 5 psi of nitrogen purge with nitrogen and use the vac pump. You will use alot of vac pump oil. Old line sets have to be flushed with rx11 or liquid flush. Use lots of nitrogen with l liquid. Use clean up driers if it's a bad burn. Acid way works also. Cut flare off and braze. Prevents headaches. On flares on mini splits you can cut flares of at the evaporator and swag with one braze joint. Flow nitrogen. Through. I always use 400 psi or more for pressure for leaks. Flare at a mini splits I use leak lock from high side chemicals at the condenser. Only rubbing alcohol can take this off. You do that at the caps to. Most techs won't know this and this stop the leaks on top of service valves and brass caps. So leak detection can only be needed at the evap return bends or the flare on a bleed externally equalize txv. Last would be at the condenser rubbing on the bottom of the pan. A coils that are old or slant have sheet metal and not aluminum. Some installers will not pull the new coil out of the case to make sure nothing is rubbing. That will cost you time and material. A little of arm flex or cork tape will fix that. Always use wet rags on plastic drain pans or condenser pads. Good vacuum of 1000 microns will make your system super dry and absorb refrigerant alot more easy!!!!! When in doubt on long Refrigeration lines use another vac pump on evap coil were sollonids valves and txv's are 1000 microns no less. This will make the competition die. If you need or don't need use leak sealer from Refrigeration supply distribution from ???? Will only bullet proof the system even better!!!!!
@gsmboutiqueable Жыл бұрын
Thanks for sharing your experience with us!!!
@AlbertFrederickLarun3 ай бұрын
Brian always gets me motivated to crush HVACR!
@SoullessProductions Жыл бұрын
As an appliance tech dealing with refrigeration this helps. Was an Auto mechanic for years then went appliance and have to deal with refrigeration. I was doing things and never really understood why until i watched this video.
@samuelg358611 ай бұрын
Outstanding class brother
@dioncurtiscurtis3188 Жыл бұрын
My supervisor must have called about a few of us 😂
@youngjedi5599 Жыл бұрын
I know right. He seemed pissed.
@ApartmentMaintenancePro Жыл бұрын
Love this stuff Bryan !
@mikelsbug8174 ай бұрын
This is very informative. Thank you
@abdulfattahkarimi8982 Жыл бұрын
Great, video. Thanks for free teach. I have a question. Some body soldering HVAC lines with Staybrite 8 and says it is stronger, cleaner and faster than cooper brazing. Do you think is it the right way and stronger than cooper to cooper brazing?
@davetysdal54424 ай бұрын
Wondering about the legality of S 8 also. Looks like it's frowned upon in residential HVAC? 10,600 psi pressure rating on the SDS. Harris says it's OK for refrigeration.
@Shawn_RHVAC Жыл бұрын
Work with Mr. Taylor on a job site issue. Guy is amazingly smart. Lol. Great guy, great team Kalos has and love all the videos you offer. Any chance you have any training on Novar systems.
@imteyazsiddiqie818611 ай бұрын
Very good lessons 👍
@abdulhvac2395 Жыл бұрын
Thank you very informative
@fixitmekanik412 Жыл бұрын
great video, thanks for sharing!
@scottjones7279 Жыл бұрын
And when is part 2?
@yorkrojas1452 Жыл бұрын
Thanks a Million!!
@Shawn_RHVAC Жыл бұрын
Are you going t on moist the remainder of the class??
@davetysdal54424 ай бұрын
Wondering about brazing safety also, so you don't start fires in houses while brazing. Dangerous? ACR pro press much safer, but $$$$.
@Badtxv Жыл бұрын
I wish I could've gone to this 😢
@hvacinstalacije1985 Жыл бұрын
Regards from Bosnia :)
@jasonthurston79910 ай бұрын
Doesn't brazing's extreme heat alter the properties of the copper and weaken it. Like it anneals if it wasn't already annealed? I've been hearing that soldering creates stronger joints when you use the right kind of solder.
@mikafoxx27176 ай бұрын
Maybe, but never is it the annealed copper bursting that causes leaks, it's cracking or rubbing through or some such.
@HVACRTECH-83 Жыл бұрын
Shouldnt have any issues using 15 with flux on cop to brass
@wagnergitirana Жыл бұрын
Very informative video. Now, what do you think of the use of RLS fittings and the cordless tool ? I tend to compare the plumbing PEX fittings from Uponor and the expansion Milwaukee cordless toll as well. My question is : is the RLS jawkit8 tool along with its copper fittings a permanent substitute of brazing torch ? I’m talking about exclusively for residential applications. I will start HVAC school soon here and I want to focus on residential only. Your input will be really appreciated. I’m a new subscriber here . Thank you !
@winstagram178511 ай бұрын
Short answer - they are a game changer for multiple reasons and so far seem to work great, but nobody knows the real world lifespan of the gaskets. The biggest difference in HVAC vs Plumbing is our pressures and temps fluctuate. The biggest resistance to this is the fact that a properly done soldered joint is 100% going to last. I think the time saving and risk reduction is worth it and would use press fittings exclusively if I was a tech. -A certified factory support rep and trainer for 5 manufacturers.
@Elisummit845 Жыл бұрын
Finally got something to add to my telegram channel 🤣. Thanks Bryan
@mauriceshumock1869 Жыл бұрын
I do residential appliance repair and perhaps it’s a different ball game but I’ve never seen anyone run nitrogen when doing any brazing or soldering. They don’t even mention it at the manufacturer trainings. Now I wonder if the oil we work with doesn’t cause any issues if we don’t run nitrogen because no one in this industry ever talks about it where I’m at. We mostly work on R134A and R600A. The capillary tubes may be smaller so I also assumed we don’t do it because maybe it will bubble the joint. I’ve also been doing it without running nitrogen for about 5 years and never had any problems that I’m aware of. I’d appreciate an opinion if you have one on that.
@whitesheatingairappliancer7101 Жыл бұрын
How are you brazing aluminum to steel or copper to steel?
@mauriceshumock1869 Жыл бұрын
@@whitesheatingairappliancer7101 I’ve never seen a aluminum to steel connection but I tried it once for fun and what worked for me was Multisol from solderweld. It’s tough for me to use but it also works for steel to copper. I only use multi sol if I don’t wanna apply too much heat. My go to for steel to copper is Sil Sol 56 and for aluminum to copper pipe connections I would only use Al-Cop braze. All from solderweld and they are all easy to use except MultiSol, at least for me
@mauriceshumock1869 Жыл бұрын
@@whitesheatingairappliancer7101 steel to copper was difficult for me for a long time but I recommend that you try Sil Sol 56. You heat up the copper a little bit and then focus the heat on the steel next to the joint until the steel is red hot, it should melt in around the joint perfectly. It never leaks for me if I do exactly that and let it cool down by itself without putting a wet rag on it. And to be honest, I’ll let even put Stay Silv brazing flux on the joint before brazing. It’s unnecessary but it works better for me.
@EarlHayward Жыл бұрын
Are you running oxy-acetylene or just acetylene? I use oxy-acetylene and a higher silver alloy and do the joint quick, so that might be the reason (if not oil)… I think gthose running air acetylene, with say a TurboTorch tip (probably oversized), are placing a lot of heat all at once causing much more oxidation inside…
@mauriceshumock1869 Жыл бұрын
@@EarlHayward I just use acetylene with a fairly small tip. The connections I make are smaller. The only other issue I’ve had is actually focusing the too much on the steel and under heating the copper. I’ve also had best results with the high silver flux coated rod. If I heat and clean it properly the joint comes out a shiny silver all the way around indicating that it’s unlikely to leak. With these joints I avoid cooling them off quickly. Just about every time I’ve done that it ended up leaking, sometimes it would take 15 min for the micro bubbles to form.
@26212269 Жыл бұрын
Awesome 👏👏👌👍
@andrewd762 Жыл бұрын
Can you use CO² as a purge gas instead of nitrogen when brazing refrigeration pipework? Thanks for the videos, I've found them very informative.
@HVACRTECH-83 Жыл бұрын
Co2,although you can get dry c02, it's much more expensive than nitrogen which is why we use it instead.
@HVACRTECH-83 Жыл бұрын
So, yes you can lol but I'd save c02 for the keggerator. Stick to nitrogen for brazing
@MR-backup Жыл бұрын
How did you exponent your "2" like that?
@andrewd762 Жыл бұрын
@@MR-backup I stuck my finger on the number 2 and held it. I then get several options like ² and ⅔ and ⅖ for example. I'm using the gboard keyboard thing on Android so it might differ for you.
@andrewd762 Жыл бұрын
@@HVACRTECH-83 The reason I was interested in using CO² instead of nitrogen is that CO² is stored as liquid when it's in a cylinder whereas nitrogen is just compressed gas so you get a lot of CO² in a very small cylinder which means it's more portable. To carry the same quantity of nitrogen you need a bigger heavier cylinder. I just wasn't sure if using CO² would result in an inferior braze or weld joint.
@lostcause4517 Жыл бұрын
Matthew Taylor is the man! I wish Walmart would of been able to keep him 😒lol
@jaymz0074 Жыл бұрын
Man good stuff
@HVACRTECH-83 Жыл бұрын
I think we all got what you meant at the end,lol, but in case anyone didnt know, oxygen is not mostly what our air is made up of, its only about 21 % of our atmosphere. Nitrogen is most of what we breathe at around 78% then the rest is c02,argon,neon
@lifjimbo7251 Жыл бұрын
He said Nitrogen is mostly what's in our air lol
@luke9129 Жыл бұрын
❤❤❤
@mox2766Ай бұрын
2nd year.... and work with guys 10+ years in the trade... and all these guys do is put caps and they get mad at me because i focus on penetration...
@KoshYTGC11 ай бұрын
I did this in grade 7
@HermanMeyers-k4x3 ай бұрын
This isn't just HVAC only my friend
@conqwiztadore221326 күн бұрын
Wow I learned more in 15 minutes than the 32 hour course I had to do for med gas. Just kidding, (only a little)