Bus Bar Protection | Centralized and De-Centralized Bus Bar Protection Schemes |

  Рет қаралды 3,782

LIGHTNING MINDS

LIGHTNING MINDS

Күн бұрын

Speaker information: Pankaj Kumar Jha
Manager, Power Grid Corporation of India Ltd.
(Power System Engineer with more than Ten (10) years of industrial experiences.)
The fundamental concepts of bus bar protection will be discussed in this series of session. In this series we will discuss about the basic concepts of Bus Bar Protection. Difference Between High Impedance and Low Impedance Bus Bar Differential Protection. The concept of CT saturation and its effect on the performance of Bus Bar Differential Protection. High impedance bus bar differential protection calculations. Centralized and Decentralized bus bar protection schemes. Concepts of Bus Zone and Check Zone in case of bus bar differential protection schemes. At the end of this series you will learn all the fundamental concepts related with bus bar differential protection. All these sessions will be in Hindi as well as English and you may watch these sessions as per your convenience.
For better understanding of the concepts explained in this session, it is desirable that following sessions must be watched:
1. Bus Bar Protection | Concepts and Applications of Low Impedance Bus Bar Differential Protection |
• Bus Bar Protection | C...
2. Bus Bar Protection | Bus Zone and Check Zone in Bus Bar Protection | Bus Zone | Check Zone
• Bus Bar Protection | B...
3. Bus Bar Protection | Concepts and Applications of High Impedance Bus Bar Differential Protection |
• Bus Bar Protection | C...
4. CT Saturation and its Effects on Bus Bar Protection | Bus Bar Protection | CT Saturation |
• CT Saturation and its ...
5. Bus Bar Protection | Bus Bar Differential Protection | High Impedance Bus Bar Differential | Part-1
• Bus Bar Protection | B...
6. Bus Bar Switching Schemes || Bus switching schemes || Bus Bar arrangements ||
• Bus Bar Switching Sche...
7. CT POLARITY || WHY CT STAR POINT IS ALWAYS FORMED TOWARDS PROTECTED OBJECT SIDE || PART-2.
• CT POLARITY || WHY CT ...
An incredible amount of time and effort is needed to develop high-quality video tutorials. Each video takes approximately 6-8 hours to complete which includes learning the concept myself, brainstorming creative ways to teach and explain the concepts, creating the presentations (if delivered through PPT mode), Setup of analysis software, video recording, and editing. Your support truly makes all the difference. So, Please like👍🏻, comment and share this video with your friends and keep watching this channel for more such videos in future.
#Lightningminds #pankajkumarjha

Пікірлер: 14
Modus males sekolah
00:14
fitrop
Рет қаралды 12 МЛН
GTA 5 vs GTA San Andreas Doctors🥼🚑
00:57
Xzit Thamer
Рет қаралды 26 МЛН
Transformer stability test
14:05
Barani Tech
Рет қаралды 36 М.
End Fault Protection or Dead Zone Fault Protection for Bus Bar Relay
6:07
RELAY PROTECTION ELECTRICAL
Рет қаралды 1,7 М.
Bus Bar Protection|Busbar Differential Protection|How busbar is protected
19:41
ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE
Рет қаралды 72 М.
SGP501 Protection of  Busbars
14:27
Lectures in Electrical Engineering
Рет қаралды 31 М.
High impedance busbar protection
7:07
stephen brooks
Рет қаралды 31 М.
Modus males sekolah
00:14
fitrop
Рет қаралды 12 МЛН