Sir you all are taking too much effort by giving free lectures. Keep up the great job. Thanks to all the members of your team.
@AkashVerma-eo3vo4 ай бұрын
Thank you so much Sir❤❤
@shashiprakash95934 жыл бұрын
Ultimate way of explaining the things
@yuvakishoreyuva104 жыл бұрын
tq sir, you are doing great job by giving free lectures.
@Sakshi-or8sl4 жыл бұрын
Thank you so much sir you saved me from a huge assignment work. Your content is great
@randomrecursive3 жыл бұрын
Thank you sir. Hamari teacher bhi idhar se hi padhati hai.
@surekhagaikwad51953 жыл бұрын
Hello Sir, why do you consider ct sec current in d same direction as that of the current flow. Even in differential prt lecture also I found this was repeated. Any reason for this consideration wen actually it shud b just d opposite. Thanks in advance.
@jatinsharma9377 Жыл бұрын
Very informative video sir...🙏🙏
@taladasandeep84973 жыл бұрын
Very Helpful...Thank you very much Sir !!!!!
@natrajrsify2 жыл бұрын
Sir, if there is a ground fault in primary side of the transformer, will fault current will return back through neutral earth of secondary? if so, even if delta /star?
@chaitanyaallu4 жыл бұрын
Sir, some of the topics that are required for gate exam are not covered..please try to cover those topics. Thank u for your amazing videos sir
@chaitanyaallu4 жыл бұрын
@@lecturesinelectricaleng Power systems Stability concepts sir
@surendrakverma5552 жыл бұрын
Very good 🙏🙏🙏🙏. Thanks 🙏🙏🙏
@42gopikrishnac577 күн бұрын
thank you sir
@RaoBonala2 жыл бұрын
Hi...Good to know and important to learn fundamentals. But the protection components currently in the industry may not be using these fundamentals or little different. Request the professor to concentrate and educate us on these. Thank you
@skumarjaipur99384 жыл бұрын
Concept clear, thank u sir
@PramodKumar-zl4gq2 жыл бұрын
Nice explanation
@rabi4144 жыл бұрын
Sir i would like to know in the case of internal fault why the returning fault current following the transformer neutral grounding path inspite of the frame grounding path
@shibajisain590410 ай бұрын
Earth fault in Delta side will reflect in primary? Please explain
@kumarasekaranp31613 жыл бұрын
Sir, How the delta side ground fault current will pass through CT2 which is connected in star connected of primary side?
@gobarrocks3 жыл бұрын
In high impedance relay R is dc polarized relay, why the relay is operating for internal faults and not for external faults as fundamental component will be contain by both
@subramaniumnandha85102 жыл бұрын
Sir good lecture
@himanshu22324 жыл бұрын
Sir I was waiting for this vedio. Thank u sir
@himanshu22324 жыл бұрын
@@lecturesinelectricaleng please sir make also vedio on bus bar size,and bus bar scheme selections for substation .
@himanshu22324 жыл бұрын
@@lecturesinelectricaleng thanks for reply.
@rangurahul3518 Жыл бұрын
Super
@jamesowusu-ansah5954 жыл бұрын
sir please, so for the metal clad type, both high impedance relay scheme (or biased differential relay scheme) and frame leakage protection schemes are used
@jamesowusu-ansah5954 жыл бұрын
at 9:21, you said the frame leakage protection is used for metal clad type switchgear installations
@sreyasentertain83454 жыл бұрын
Regarding machines... Reactive power directly proportion to magnetizing current and load..invrsly to power factor.. So, is it right.??... Getting confusion n pls tell me sir
@sreyasentertain83454 жыл бұрын
@@lecturesinelectricaleng ok sir thank you..
@cueetryadavji65823 жыл бұрын
Sir please upload the lectures on fault bus protection
@fayazobili21823 жыл бұрын
My question in frame leakage protection How to leakage current flow through using transformer.
@rakeshram16083 жыл бұрын
Internal or external faults max current is same or different