Cable Termination In Panel | Terminate Medium Voltage Cable | Underground Cable Termination

  Рет қаралды 3,402,597

MM Asif

MM Asif

Жыл бұрын

♥LIKE | ♥COMMENT | ♥SHARE | ♥SUBSCRIBE
Hello! Friends I am Muhammad Asif Ek Aur new video♥ Cable Termination In Panel | Terminate Medium Voltage Cable | Underground Cable Termination | MM Asif | ke sath Huzoor Hoon.
In this video, we show you how to terminate a power cable in a transformer And show you how to properly terminate an 13.8KV power cable in a transformer.
This video demonstrates how to terminate medium voltage cables in a panel.
This video demonstrates how to terminate a 500mm power cable using a transformer.
This Video will show you various steps that are involved in Medium Voltage (MV) Cable termination. Hope this is helpful.
This video demonstrates how to terminate medium voltage cable using an underground cable termination method.
Meri video acchi Lage toh please like Kijiye comments kijiye aur mere is channel ko jis ke NAME ♥MM ASIF hy is ko subscribe kijiye Shukriya. aapka Pyara dost Mehar ♥Muhammad Asif.
♥Plz subscribe kijiye
kzbin.info/door/iDA...
♥ ♥ ♥ ♥_____/LINKS\_____♥ ♥ ♥ ♥
► Facebook Page:➜ / mm-asif-564997130539877
► Instagram:➜ / asifshazada. .
► Google+:➜plus.google.com/b/10971302588...
► linkedin:➜linkedin.com/in/mm-asif-918258173
====__|Watch More Videos|__====
♥How To Electrical Pole Size In Urdu/Hindi | Types Of Electrical Pole Stay | Bijli Ka Khamba |
► • How Many Types Of Elec...
♥How To Use High Voltage Tester | Electric Detector Work | High Voltage Detector | Urdu/Hindi
► • High Voltage Detector ...
♥How To CT Energy Meter Connection | 3 Phase CT Meter | CT Installation In Urdu/Hindi |
► • How To CT Energy Meter...
♥How To Cable Size | Cable Size Chart | Cable Size Chart With Load | Cable Size Chart In Urdu/hindi
► • How To Cable Size | Ca...
♥How To Use Hilti Gun | Hilti Nail Gun | Hilti Powdered Actuated Tools | INTRODUCING | Urdu/Hindi
► • How To Use Hilti Gun |...
♥Fire In Electrical Store In Riyadh Saudi Arabi | Al janahain | الجناحین الریاض سعودی عرب
► • Electrical Fire In Wal...
♥Electrical Work Maintenance In Saudi Arabia Urdu/hindi
► • Electrical Maintenance...
♥Fuse Lagaane Ka Tarika 33kv/11kv Urdu/Hindi
► • Electrical Fuse Types ...
♥Track: Weero - Mates [NCS Release]
Music provided by NoCopyrightSounds.
Watch: • Weero - Mates [NCS Rel...
Free Download / Stream: ncs.io/MatesYO
#Cable_Termination
#Underground_Cable_Termination
cable termination in panel, terminate medium voltage cable, underground cable termination,
11kv xlpe armoured cable heat shrink termination
11 KV power cable termination
11 KV underground cable termination
Cable termination kaise kare

Пікірлер: 525
@unclefatbloke687
@unclefatbloke687 Жыл бұрын
Guys, NO! You do NOT use a naked flame on the shrink sleeves!!!! Heat yes; naked flames no!
@user-fn8wy4jq1j
@user-fn8wy4jq1j Жыл бұрын
Желаю тебе автор этого видео всю оставшуюся жизнь слышать бесконечно музыку из этого произведения!
@Luzgar
@Luzgar Жыл бұрын
If you are going to only use music for sound, and if you are going to loop it, please choose a song that is longer than 15s.
@UltraGamma25
@UltraGamma25 Жыл бұрын
Yes, it's fucking annoying
@maifeng
@maifeng Жыл бұрын
Personally I prefer a good 10s loop to a shitty 5 minutes song
@galaxiedance3135
@galaxiedance3135 20 күн бұрын
I wanna make that song my ringtone. I had no problem with it. I was actually more interested in what they were doing than listening to the song.
@ainafikade
@ainafikade Жыл бұрын
I just got back from a subsea cable termination for chevron in angola, power and fiber, the experience was awesome
@MW-dd4nd
@MW-dd4nd 11 күн бұрын
Just out of curiosity, what is your background and how did you get into this? I'm an electrician and high voltage SAP in the UK and would love to see this side of the industry
@aftbit
@aftbit Жыл бұрын
9:00 seems like the most dangerous part, both for the cable conductors and the bloke's thumb.
@rickymundy8663
@rickymundy8663 Ай бұрын
Guys did a good job. I have worked with different companies providing UD training. Some companies don’t provide enough training and the proper tools to properly make these terminations. My experience has taught me that some of the less experienced think that if it holds upon energizing everything is ok. They do not know or realize that improper termination of medium voltage cables with the proper tools will eventually fail prematurely. I came up with I company that provided the training that taught us why we take all the proper steps in UD terminations and the proper tools. While providing training most of those that didn’t follow each step required by manufacturers just didn’t know. Most these guys want to do it right
@mmasif7364
@mmasif7364 Ай бұрын
👍
@DrHarryT
@DrHarryT Жыл бұрын
Scoring the aluminum when removing the white nylon layer is a no, no. Yes I have done industrial underground power vaults and you don't score the conductor with a blade while removing insulation.
@LordLorenzo834
@LordLorenzo834 7 ай бұрын
Mr pedantic I don't know how you even seen that , a bit of scoring on the cable isn't the end of the world man
@DrHarryT
@DrHarryT 7 ай бұрын
@@LordLorenzo834 Ot's a no no per electrical codes.
@LordLorenzo834
@LordLorenzo834 7 ай бұрын
@@DrHarryT I know I'm an electrician , as long as the cuts are not deep and non of the strands are cut off thus reducing the csa of the conductor which is not gonna happen on cable this size, then it will be fine but I won't disagree with you that its a no no I'm just saying cable this size with a slight mark from a Stanley blade.. not really an issue is it let's use some common sense here
@DrHarryT
@DrHarryT 7 ай бұрын
@@LordLorenzo834 It was well over 30 years ago and I was not actually making the connections but an observer apprentice, Working with MCM1000 AL they had specialized strippers that cut 95% through the plastic rolling it in a circle with end cutter set to the same to cut down the length of the cable so the plastic would easily peel off leaving the AL completely unscathed. The thing about AL is once you score a strand it creates a fracture point when you crank it down in the lug and the strands distort, it can cause strands to fracture/break completely through. AL it brittle like that. Of course you must also use Noalox as I recall.
@frankweatherford6848
@frankweatherford6848 Ай бұрын
Seriously! I built a few load breaks as well. Yes i saw a couple things i would do different but the teamwork housekeeping and attention to detail was pretty damn good. What stood out to me was when my man filed any burrs off lug after crimping. R That spoke volumes. I was trained by 3m and ive had to build these things in nasty paper mills and pwr plants. These guys are better than most of the shit sticks I left behind in contracting. I say if it passed high pot test and im sure it did then good job.
@mingyitan6388
@mingyitan6388 Жыл бұрын
The craftsmanship is very skilled. For future inspection and maintenance, I feel that if the three-color tape is wrapped on the wiring cable to separate the phases, and whether the phase sequence is marked on the cabinet body will be clearer to the staff.
@deang5622
@deang5622 Жыл бұрын
No. Phase sequence is not determined by the body of the transformer. Phase sequence is determined by the actual phase of the voltage on the cables. You can actually change the order of the cables connected to the transformer and as long as the output cables are also correspondingly changed, everything is good. So the correct way to indicate the phase of the electricity is to mark the cables first and foremost. You cannot not do that. It must be done.
@rajthanya
@rajthanya 11 ай бұрын
This is a ticking time bomb. Get a qualified Jointor . Jus pay attention to how he removed the seni con layer,This is a NO NO.
@user-cs3el8xr9t
@user-cs3el8xr9t 10 ай бұрын
@@rajthanya с помощью ножниц для резки пластиковых труб... SUPER-EGO не делает инструмент для снятия изоляции с кабелей. Наружные проволоки надрезаны по кругу...
@jenswesterburg18
@jenswesterburg18 8 ай бұрын
Manchmal nervig, aber manchmal auch schön das es hier Standards gibt.... Oh mein Gott ....
@sebastienghangha3024
@sebastienghangha3024 Жыл бұрын
Thanks from France, really good work !
@chevypu4
@chevypu4 4 ай бұрын
I'm not really qualified to question anything but wouldn't a heat gun be safer than risking frying insulation from the cables?😮😮
@PATELHARSHOHM2693
@PATELHARSHOHM2693 10 ай бұрын
crimiping start always from bottom of lugs ....like this chance of cable to sleep downwards
@user-sf2bx1dn3h
@user-sf2bx1dn3h Жыл бұрын
Professional job well done
@user-ly9gl8lp9y
@user-ly9gl8lp9y Жыл бұрын
Во дела, даже инструкцию прочитали.
@AraCarrano
@AraCarrano Жыл бұрын
How to derate the line by scoring the outer row of conductors. @ 9:00
@TheHatton7065
@TheHatton7065 7 ай бұрын
Looked like it was done by the bloke with the conduit cutters. Not good
@phonkyfeel1
@phonkyfeel1 Ай бұрын
Doesn’t that cause resistance/heat and worse? I am taking my first electronics class.
@FOH3663
@FOH3663 9 күн бұрын
​@@phonkyfeel1 It can yes. You just want symmetry in everything ... it can create a failure point.
@psychiatry-is-eugenics
@psychiatry-is-eugenics 7 күн бұрын
Wonder if there is a better way to do that
@FOH3663
@FOH3663 7 күн бұрын
@@psychiatry-is-eugenics Just have to be more careful when initially using the cutters ... they dug in too deep. You want to remove the last few mm of material carefully by hand.
@alvaromachacon6317
@alvaromachacon6317 Жыл бұрын
Excelente presentación muy buena gracias
@andreymatuznyj1043
@andreymatuznyj1043 Жыл бұрын
Я думал, будет вторая серия, третья. А тут , в один ролик уложился ! 23 мужика , две недели ставят розетку ! ВЕЩЬ!!!😂
@slesarg65
@slesarg65 Жыл бұрын
У них оплата повременная, это они ещё на обед торопились!
@MoritzvonSchweinitz
@MoritzvonSchweinitz 10 ай бұрын
How come they applied (dieletric?) silicone grease to the contact area? Shouldn't grease be applied after making the contact crimping?
@AndyIsHereBoi
@AndyIsHereBoi 21 күн бұрын
I assume they do that to slip the bigger piece over?
@AhmadKhan-ce7wx
@AhmadKhan-ce7wx Жыл бұрын
ماشاءاللہ میں بھی ریاض میں شرکہ کھربا میں اس کام کی ہیلپری کرتا رھا بہت اچھا کام ھے
@karl7796
@karl7796 Жыл бұрын
You kicked the aluminum conductors with the conduit cutters when you removed the inner insulation layers and you should not use retractable blade cutters on HT cable, there are special knives for removing insulation. Did you put dielectric grease on the TX stems before putting the boots on?
@xaxabdo
@xaxabdo Жыл бұрын
Where is the QA at!
@schamberlain1
@schamberlain1 Жыл бұрын
They probably don't even have multilins or sweitzers on the high voltage side.
@karl7796
@karl7796 Жыл бұрын
@@schamberlain1 I should have said nicked the conductors, but that is what happens if you use a stanley knife to cut through the outer layers. We use to use venitian blind cord to cut through the outer layers, the friction cut through the plastic layers with out damaging the copper conductors.
@XREXP0
@XREXP0 Жыл бұрын
This looks like a dry climate
@HighestRank
@HighestRank Жыл бұрын
@@XREXP0 It is dry, and so they don't have horizontal venetian blinds, but the vertical ones with a stiff staff to open & close them.
@SlickManChoux
@SlickManChoux 5 ай бұрын
Good job guys with adequate toils il would be better
@Boraxo
@Boraxo 9 ай бұрын
Did you use a dull axe to cut those holes in the clamp bracket ?
@JustBadMeAndI
@JustBadMeAndI Ай бұрын
No, they seem to have burnt the holes with a welder
@user-df1ez2ti3s
@user-df1ez2ti3s 3 ай бұрын
"Глаза боятся руки делают" " Опыть приходит годами" "Семь раз отмер, один раз отреж " Музыка несовсем,кто монтировал ролик имей ввиду ! Работа окуратная, хорошая.👍
@Alsifer12
@Alsifer12 Жыл бұрын
why did they lubricate the exposed part of the cable with silicone this will worsen the contact
@alexs2778
@alexs2778 7 ай бұрын
It's probably has dielectric properties so when tightened IF any is between it shouldn't effect much, on the other hand it should provide waterproofing, oxidation and maybe lessens the chance of arching (not sure how effective on high voltage but on main breaker panel thin layer on rail contacts might prevent arching when breaker is installed in that spot..
@romeowhiskey1146
@romeowhiskey1146 Жыл бұрын
You FLICK the switch... The LIGHTS go on! Good work, gentlemen!
@panoramicview698
@panoramicview698 Ай бұрын
Good job. So many unhappy people here seeing work being done well
@mmasif7364
@mmasif7364 22 күн бұрын
Thank you😍
@brettvanwey9419
@brettvanwey9419 Жыл бұрын
Y’all did good until you took off the vinyl insulation and went too deep, putting a deep nick in all the outer conductor strands.
@rajatariq6808
@rajatariq6808 10 ай бұрын
Mr Asf I appreciate ur work dedication / tc urself during working
@claroypunto3774
@claroypunto3774 Жыл бұрын
Saludos DESDE BOLIVIA... soy Tecnico Electricista.. muy buen video 👌
@almosthuman4457
@almosthuman4457 Жыл бұрын
its nice to see someone doing things the right way in one of these videos.
@patrickd9551
@patrickd9551 9 ай бұрын
If you want right, you better watch other channels, like jointech cabling. As for the issues: They didn't apply the proper torque spec in the end and they scored the conductor, as you can clearly see around the 9 minute mark.
@asr1460
@asr1460 Жыл бұрын
Чудова робота! Молодці!
@lizhageman5457
@lizhageman5457 Жыл бұрын
Good work! Big cable, compared to the physical size of the transformer. 500 kcmil @ 13.8 kV, corresponds to 10 mVA?? Transformer seems smaller.
@rondeal3823
@rondeal3823 4 ай бұрын
Fellas. Think about your eyes . You have flakes of aluminum flying. We always wear eye protection . Especially when cutting wire with saw.
@rajkumarponnuthurai9696
@rajkumarponnuthurai9696 Жыл бұрын
Good job 👍 We shall take little more care when sleeving insulations and clamping. Thanks for the video.
@user-nh2ol5us2h
@user-nh2ol5us2h Жыл бұрын
интересный вариант полупроводящий слой ножом снимать так бывает на одном кабеле из 100 и не нужно говорить что это только на импортных , так же там инструмент нужен
@rajeshs4447
@rajeshs4447 Жыл бұрын
Don't put silica grease on conductor,
@rogerdodger3477
@rogerdodger3477 Жыл бұрын
I know right? Doh!
@andyblackpool
@andyblackpool 18 күн бұрын
Very professional and neatly done job.
@mikeiver
@mikeiver 7 ай бұрын
Much prefer load break connectors. Fast off and on loaded or not, simple grounding of the cables and the primary for safe service work. Far superior. But good job on this one none the less.
@ibrarakram1963
@ibrarakram1963 Жыл бұрын
This is why Pakistan has no running electricity...
@miguellopes4153
@miguellopes4153 2 ай бұрын
Parabéns, é satisfatório ver um trabalho desses ser concluído sem falhas. Pernambuco - Brasil.
@dolkong_1049
@dolkong_1049 Жыл бұрын
꼼꼼하게 설명 잘해주시네요
@2023TMc
@2023TMc Жыл бұрын
No eye protection but hard hats 😂
@HamguyBacon
@HamguyBacon Жыл бұрын
Its not live
@tomwright3390
@tomwright3390 4 ай бұрын
Nice work but please wear safety glasses especially when using a Sawzall to cut wire!
@juanpablorestrepo5540
@juanpablorestrepo5540 Жыл бұрын
Excelente trabajo 👏🏻 👍🏼 💪 pero algo muy importante los EPP Elementos de protección personal ✅️
@RajinderKumar-xr5he
@RajinderKumar-xr5he 8 ай бұрын
Why you have not filled gap between lug and adaptor. this may create partial discharge
@murtazahussain5371
@murtazahussain5371 7 ай бұрын
i have question do we use phase sequence on Higher side of transformer like in this case he didnt use any sort of color for different phases.
@TheGodpharma
@TheGodpharma Жыл бұрын
How do you know which cable is which? They all seem to be identical.
@Gameplayer55055
@Gameplayer55055 Жыл бұрын
worst fear: accidentally cut the cable shorter so it doesn't reach the contacts
@j5892000
@j5892000 Жыл бұрын
Get so m.h e thick ass solder and a torch lol.
@jannejohansson3383
@jannejohansson3383 Жыл бұрын
There's even parts for that, if someone mess up, or changes needed. Otherwise it needs I-joint and some cable, angry boss and try again! $$$
@swsuwave
@swsuwave Жыл бұрын
Other worst fear: getting the phase rotation wrong when its done.
@HighestRank
@HighestRank Жыл бұрын
kzbin.info/www/bejne/nGHOY5SLnt-datU
@everydaycompress4259
@everydaycompress4259 Жыл бұрын
use extended elbows EZ FIX ...we have even cut off OLD elbows short and still re use the old cable just have new elbows and lightning arresters ..this is just a 3 phase going IN im sure they got 3 more on the other side.
@delicious_seabass
@delicious_seabass 9 ай бұрын
Three guys to do a one man job an the rest sitting around watching.
@inq752
@inq752 18 күн бұрын
imagine the GDP growth
@kouamekouakouraphael9402
@kouamekouakouraphael9402 7 ай бұрын
❤❤❤ Super
@nb117
@nb117 Жыл бұрын
Excellent professional installation.. Good Job!!
@BarfusWOW
@BarfusWOW Жыл бұрын
not really - no safety glasses at all anywhere.
@oldtimer2192
@oldtimer2192 Жыл бұрын
The cable clamping bracket was pretty average!
@ZloySok
@ZloySok Жыл бұрын
Странно что при таких сечениях кабеля точка контакта совсем маленькая, там где гайка.
@Grishagin1997
@Grishagin1997 Жыл бұрын
Это высоковольтка там и не нужно большое сечение, там токи очень маленькие, а вот 0.4кВ уже нужно больше сечение из-за тока
@legendarniyMichail
@legendarniyMichail Жыл бұрын
Сечение выбирают исходя из патерь. На длинной линии прийдется переразмерить сечение что бы снизить потери. Иначе ПБВ не хватит и напряжение будет сильно зависить он нагрузки. А гужоны в изоляторах бывают разными здесь видно что тр-р не сильно мощный.
@user-zx4nw1pr6q
@user-zx4nw1pr6q Жыл бұрын
Да многое странно! Зачем высокую сторону подключать таким большим сечением провода?, если исходя из расмеров тр-ра, то его мощность не так велика. Еще обратил внимание, что когда закроется крышка, то клеммы окажутся совсем рядом с нею. А заглушки на клемах, это так себе... всёже 14 кВ.
@Grishagin1997
@Grishagin1997 Жыл бұрын
​@@user-zx4nw1pr6q расстояние там позволяет, у нас ячейки открываешь и сразу ВН стоит и кабель, и расстояние 10см, про RM6 молчу там еще меньше места, до крышки ячейки, все же нагрузка там есть, по высокой максимум 70А, ТР на видео примерно 1600А по низкой это в районе 2312А
@user-zx4nw1pr6q
@user-zx4nw1pr6q Жыл бұрын
@@Grishagin1997 И тем не мение, там сечение минимум 300 квадрат, и на ток в 70А? Ну да ладно. Как говорится, хозяин-барин. А вам спокойной ночи!👋😉
@janeli5725
@janeli5725 8 ай бұрын
Nowadays, there is no need for stamping pliers on the terminals. It is safe and fast. Also, the protective cover is not very good if it is heated by fire. Now there are terminals that do not need to be burned. Just put it on and it can be used.
@joeldicks2181
@joeldicks2181 Жыл бұрын
Great work.
@emrahklc3391
@emrahklc3391 4 ай бұрын
Thank you for sharing.
@paolodolimpio1382
@paolodolimpio1382 Жыл бұрын
Crimping the terminal directly on the insulator is an unnecessary risk in my opinion ... it could break !!! for the rest, great manual skills, word of an electrical technician
@sumuduasiri
@sumuduasiri Жыл бұрын
Definitely. 🙏
@blackviper7754
@blackviper7754 Жыл бұрын
So are you electrician?
@paolodolimpio1382
@paolodolimpio1382 Жыл бұрын
@@blackviper7754 Yes I am an electrical technician and I have worked with terminals up to 30KV I have never crimped directly on the insulator above all in glass or porcelain where breakage is at high risk
@johngy6296
@johngy6296 Жыл бұрын
@paolo D'Olimpio - I thought the same thing. I’ve seen plenty of cracked bushings cause ground faults, spectacularly.
@user-go6gw8qy8j
@user-go6gw8qy8j 8 ай бұрын
I specialize in this! Only minor errors but congrats.
@peterbird3932
@peterbird3932 5 ай бұрын
Those nuts need to be torqued to mfg. settings. Didn't see a torque wrench being used.
@zgrad2008
@zgrad2008 8 ай бұрын
Больше всего мне понравилась идея надеть на контакт "Y1 конденсатор", выполненный в виде внешнего черного корпуса. Вот так и нужно заводить электричество на дачу и в квартиру, т.е. с использованием конденсатора в месте контакта ввода. Не силен в физике, но по-моему по проводкам заземления из кабеля будет уходить на землю вакуум через конденсатор. Было бы любопытно измерить емкость между кабелем и заземлением, наверное ~2nF.
@josephsouza2160
@josephsouza2160 Жыл бұрын
Excellent job
@atnstn
@atnstn 9 ай бұрын
Respectable professionalism. Reall enjoyable watch.
@GauravSharma-kn3fh
@GauravSharma-kn3fh 9 ай бұрын
why did you cut the sleeve from the adhesive coating side? and you need to use the tool for making cut on Semicon.
@tatangsumarna3850
@tatangsumarna3850 6 ай бұрын
God job brother and bravo every one amin❤
@restorerestoration4705
@restorerestoration4705 Жыл бұрын
lubricating contact joint is priceless 🤦
@NeverTalkToCops1
@NeverTalkToCops1 Жыл бұрын
Plus the box cutter technology.
@BramBiesiekierski
@BramBiesiekierski 10 ай бұрын
My favourite was the clamp/strap that secured the cable in. It looks like they drilled the holes by shorting it out on a car battery.
@BramBiesiekierski
@BramBiesiekierski 10 ай бұрын
At 0:51😂
@mohammadhoseinghadirzade-mo3fu
@mohammadhoseinghadirzade-mo3fu 6 ай бұрын
👍👍👏👏بسیارعالی
@lovenkeytermitus673
@lovenkeytermitus673 7 ай бұрын
Nice work ❤
@noelbyrne8735
@noelbyrne8735 Жыл бұрын
Absolutely nothing is right about this installation. 1: wrong type cable for the job, single cores in a trefoil should have been used instead of a multi core cable 2: wrong type termination kit used, a break out or multi to single core kit should have been used which keeps the screen on all the way to the dead break elbow. 3: no grommet or gland used to seal the in enclosure from ingress or moisture 4: the clamp is installed at the crutch which will cause stress and early kit failure Solution: have your technicians trained and educated properly. Government should introduce a standard based apprenticeship system. Follow jointing kit instructions to the letter.
@bstelectronics9627
@bstelectronics9627 Жыл бұрын
Before applying silica grease.. Should be rubbed with smooth sand paper on grey layer
@donniedollarhidejr.2766
@donniedollarhidejr.2766 Жыл бұрын
No, you shouldn't. One little scar on the dielectric layer and bye bye termination.
@remist
@remist Жыл бұрын
why
@Alfirr
@Alfirr Жыл бұрын
Hello! If I understand correctly, you work in oil production. Are you connecting a control station and a step-up transformer? If yes, then compliance with safety regulations is at a low level ... You work at least - without a protective helmet, goggles and gloves...
@evgeneevgen8177
@evgeneevgen8177 10 ай бұрын
А инструмент кабельный нет не знаем какой нужно использовать?
@NoneFB
@NoneFB Жыл бұрын
Does the opening at bottom get closed off or can any animal build a nest/home up there?
@adrianosantos9709
@adrianosantos9709 7 ай бұрын
Very Good....
@ms.appleberry1820
@ms.appleberry1820 Жыл бұрын
good job!
@wesleyoliveira126
@wesleyoliveira126 Жыл бұрын
Good job!!!
@h_a85
@h_a85 11 ай бұрын
I don't get it, is that the termination?!, just some heat shrink tube? We produce pre moulded and cold shrink cable terminations and joints
@GOVAUS1
@GOVAUS1 8 ай бұрын
The real question is: can you still do an MRI with aluminum chips in your eye?
@jasondsr.pillora968
@jasondsr.pillora968 Жыл бұрын
Good work.
@Ackmipro
@Ackmipro Жыл бұрын
Great job
@mohbouhouch674
@mohbouhouch674 10 ай бұрын
Good job brothers
@Mabreujf
@Mabreujf 4 ай бұрын
Trabalho bonito e profissional. Parabéns a toda a equipe!
@softbytesunlimited
@softbytesunlimited Жыл бұрын
Nice work 👏
@briwire138
@briwire138 10 ай бұрын
great job lads.
@vikashvikash6346
@vikashvikash6346 9 ай бұрын
Ram ram Asif ji 🙏🙏
@mjaved2978
@mjaved2978 Жыл бұрын
Knowledgeable able vedio
@SaleemAhmad-dw7dw
@SaleemAhmad-dw7dw 11 ай бұрын
Very good job
@christopherleubner6633
@christopherleubner6633 Жыл бұрын
Excellent work. It might get a fault but it sure AF isn't going to be the primary feed connection 😎
@patrickd9551
@patrickd9551 9 ай бұрын
You sure? Did you see them apply proper torque on the bolts using the proper tool? Did you not see the scoring of the outer conductor @9:00? I sure as heck did not. So if you please, would you guide me to those missing pieces?
@Milten130
@Milten130 9 ай бұрын
@@patrickd9551 also resistance to ground is not important there, they can just go by with crusty torch cut metal pieces
@patrickd9551
@patrickd9551 9 ай бұрын
@@Milten130 true story: I went to an outdoor lan party back in 2000. Big army tent, diesel gens, etc. The power was ..... bad. Loads of parasitic voltage through the earth lead. So we all tied our computers to a piece of UTP cable and wrapped it around a couple of tent pegs. Then through the magic of powerstrips, all our computers were all cross-connected to many small grounds. It was enough from getting us zapped by our own computers tho, as stupid as it looked.
@Vladynko1
@Vladynko1 Жыл бұрын
Nice working.
@x84pav84x
@x84pav84x Жыл бұрын
Снимать изоляцию надо не повреждая жилы.
@goodthinking3552
@goodthinking3552 Жыл бұрын
Saudi electricity company 👍
@doglover5461
@doglover5461 5 ай бұрын
nice video boss
@user-hl5qy9cz4w
@user-hl5qy9cz4w 8 ай бұрын
변압기 각 3상에 터미널 물려놓고 압착기 찍는 거는 처음 보네요.... 잘못하면 변압기 부싱 망가져요..
@marciojose8993
@marciojose8993 5 ай бұрын
VERY GOOD,,
@PplsChampion
@PplsChampion Жыл бұрын
good cable music
@luigicristiani7709
@luigicristiani7709 Ай бұрын
The right jobs are done with the right tools. Just like in the 1970s when I studied electrical engineering in Rome PS ; is the Bucholtz relay still used?
@CEE-POWER
@CEE-POWER 6 ай бұрын
Nice
@alassaneniang7669
@alassaneniang7669 5 ай бұрын
Good job
@lumyre1706
@lumyre1706 9 ай бұрын
First time ever?
@tsclly2377
@tsclly2377 12 күн бұрын
looking at the cable, I think that some-one misplaced a decimal point, as one would not want to use any voltage below 400V/3phase for any substantial length .. this looks like 200V and looking for a 1.5% drop. maybe this is cheaper than a transformer in the short run. the cable looks to be 2.5cm dia. PLUS the definition of " Medium Voltage Cables" is 2.4kV and above.. so is it MW that we are really looking at?
@campkohler9131
@campkohler9131 Жыл бұрын
Seeing workers struggling to cut big conductors with a recip saw reminds me of an electrician on another channel who uses a one-hand-held, cordless bandsaw that would make quick work of it. Buy one!
@gessesolza3128
@gessesolza3128 Жыл бұрын
Faltou o óculos
@user-gt6sl6bd8n
@user-gt6sl6bd8n 3 ай бұрын
Nice 🎉
There is a Reason Why Underwater Power Cables are So Expensive
9:42
Home Automation 32CH Distribution Board DIY | Smart IOT Project 2023!
17:33
Did you find it?! 🤔✨✍️ #funnyart
00:11
Artistomg
Рет қаралды 113 МЛН
SHE WANTED CHIPS, BUT SHE GOT CARROTS 🤣🥕
00:19
OKUNJATA
Рет қаралды 10 МЛН
ШЕЛБИЛАР | bayGUYS
24:45
bayGUYS
Рет қаралды 663 М.
Replacing a Pad Mounted Residential Transformer
10:20
Randall Wingett
Рет қаралды 2,6 МЛН
How Do Substations Work?
12:38
Practical Engineering
Рет қаралды 3,2 МЛН
MDP panel termination 3c×70mm LV cable
15:35
Y you channel
Рет қаралды 8 М.
A closer look at Padmount Transformers
10:15
Bobsdecline - Lineman blogger
Рет қаралды 626 М.
Switching 11kV VCB Tamco
7:34
competence 33kv
Рет қаралды 2,4 МЛН
Installation of a Heatshrink Termination on a Three-core MV Armoured Cable
16:12
REPL International Ltd.
Рет қаралды 154 М.
How 2500KVA Electric Transformers are Made
12:40
Talentist
Рет қаралды 2,8 МЛН
Medium Voltage Switchgear : A Beginner’s Guide | TheElectricalGuy
11:05
Gaurav J - TheElectricalGuy
Рет қаралды 21 М.
Did you find it?! 🤔✨✍️ #funnyart
00:11
Artistomg
Рет қаралды 113 МЛН