Calibrating a Test Mark Pressure Meter

  Рет қаралды 40,536

Test Mark Industries

Test Mark Industries

Күн бұрын

Пікірлер: 14
@jesusglopez8430
@jesusglopez8430 2 жыл бұрын
Thanks for sharing, very Educative and Informative.
@winnipegkevin1
@winnipegkevin1 8 жыл бұрын
Nice video. If had to make any needle adjustments during calibration, I would be re-checking my IP to make sure all is still well. I have never seen the glass-plate method mentioned by other commentators. Not the common procedure around here, I guess. Sounds like more trouble with glass plate and a scale.
@kromekicks
@kromekicks 7 жыл бұрын
What does it mean, if when I open the petcock (to fill cylinder) and it automatically fills the cylinder. Without the need to push down on the main air valve. Any help would be appreciated. Thanks
@jeffreysouth
@jeffreysouth 11 жыл бұрын
What is the volume of the graduated cylinder? Once you adjust it to 5% does that mean that your initial pressure is calibrated to 3%?
@samanthatreutel1609
@samanthatreutel1609 12 жыл бұрын
There are a number of variables related to the exact volume of the water needed to fill bowl and the amount needed to extracted to check throughout the range of operation. The water should have all air evacuated and be at room temperature. The empty meter should be weighed and then filled with water and weighed again with the weight of water needed to fill the bowl. That weight times the percentage within the range of operation of the check gives the weight of water to remove for each percentage
@markbalcom5408
@markbalcom5408 7 жыл бұрын
you talk about adjusting the tabs if the gauge doesn't read zero, can you talk about that, also every video I have seen on air meter calibration does it on a new meter, that's easy to do, doing one on a meter that's been used and abused is a little harder.
@tariqabdullah3091
@tariqabdullah3091 9 жыл бұрын
I want aggregate correction factor
@aseeroha
@aseeroha 7 жыл бұрын
Is that per ASTM C231?
@captnhowdy01able
@captnhowdy01able 9 жыл бұрын
the calibration procedure is wrong, where is your glass plate to make sure you have zero air? and when filling the meter with the tube you are suppose jar it as you add water shaking it introduces air into the system, and where is your weights for empty vessel with plate? and empty vessel with water and plate? you need those to calculate actual reading against gauge reading
@Lumens1
@Lumens1 6 жыл бұрын
Water not confirmed to be 23.0 C. No weighing of the discharged water in the graduated cylinder? No calculating air content by water discharged? No check at 10%? This was not done in accordance with ASTM
@jamesm1651
@jamesm1651 4 жыл бұрын
in ASTM C231 (Section 8.3.2.1) states "Jar the meter gently until all air is expelled from this same petcock." You are not supposed to shake it like that
@jamesm1651
@jamesm1651 4 жыл бұрын
Also petcocks should sty open while you pump air into the chamber. That way you know if the pump is leaking
@magdymohamed1640
@magdymohamed1640 5 жыл бұрын
Very good
@LuisAntonioCastelletFernandez
@LuisAntonioCastelletFernandez 7 ай бұрын
Calibración C0170/F
ASTM C231 - Air Content of Concrete by the Pressure Method
6:47
Cttp Arkansas
Рет қаралды 106 М.
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
How to Calibration a Pressure Meter - ASTM C231 and C29
22:03
Type B Pressure Air Meter Assembly
3:56
Myers Associates, Inc.
Рет қаралды 2,5 М.
ASTM C138: Unit Weight, Yield, & Air Content Gravimetric
16:14
james Lee (TechTraining)
Рет қаралды 108 М.
Taze Beton Hava İçeriği Deneyi  - Concrete Air Test
5:25
Beton Kalite Kontrol
Рет қаралды 29 М.
ASTM C173-Air Content of Concrete-Volume Air Meter
19:06
Matt OReilly
Рет қаралды 26 М.
Blackboard ASTM C138
16:46
james Lee (TechTraining)
Рет қаралды 57 М.
What Is Air Entrained Concrete?
1:54
Creating Concrete
Рет қаралды 9 М.
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН