call for AC tripping breaker

  Рет қаралды 131,769

steven lavimoniere

steven lavimoniere

Күн бұрын

Пікірлер: 171
@specialoperator8902
@specialoperator8902 6 жыл бұрын
Are you sure ya got “No Powah”. 😂😂😂🤣🤣🤣
@RG_sssSMOKING
@RG_sssSMOKING 6 жыл бұрын
Damn, 40+ years doing electrical work and never seen a disconnect wired that way and I seen a bunch of bad wiring. Well done Steven
@BronxGummer
@BronxGummer 4 жыл бұрын
17:10 - I've seen Steve fix all kinds of leaks, except the leak from his nose. Steve !!!!!! I love you KID - just having some fun with you. You're the best and I love your videos. Thanks
@RocketFast321
@RocketFast321 7 жыл бұрын
One thing my teacher told us HVAC tech has to know everything, electric, plumbing, and ect.
@themitchielpricer
@themitchielpricer 3 жыл бұрын
ive been in hvac high rise building mechanical maintence over 45 years now retired people have no idea what it takes & the education & skill set required its you have it or you dont notice how steven explains every thing he finds& asks questions right when he meets the customer ..thats what i was taught even though hes a little short tempered thats the real deal
@PioloQuiboloy
@PioloQuiboloy 2 жыл бұрын
A little bit of every trade
@adamrspears1981
@adamrspears1981 7 жыл бұрын
I love it when customers set the price. Under a $1000 my ass! Great job Steve. Thanks for all your uploads.
@Blobjonblob
@Blobjonblob 7 жыл бұрын
Baby dog protecting the Lavmobile.
@tenkara1309
@tenkara1309 7 жыл бұрын
iShootBandits . I seen that, at 14:30 she was "laying down the law".
@chris56a
@chris56a 5 жыл бұрын
instead of going to trade school classes i just watch your videos
@garyglanz403
@garyglanz403 5 жыл бұрын
About the evaporator coil, I'd measure the plenum to see if an outflow coil would work. They're less expensive and easier for one man install. Some of the horizontal coil are huge now.
@whitesheatingairappliancer7101
@whitesheatingairappliancer7101 7 жыл бұрын
Steve it didn't look like they added a dip in the refrigerant line for oil return. Thanks for the video.
@erikj.2066
@erikj.2066 7 жыл бұрын
"I won't call anyone else". Please call someone else! I bet that guy's going to need to be revived when he gets the quote for the new system.
@titolopez4270
@titolopez4270 7 жыл бұрын
It would be great if you can put the video when you I stall this unit. Thanks Steve
@rjboxingit3368
@rjboxingit3368 2 жыл бұрын
My AC Breaker trips instantly when setting to cool. The outdoor unit is a Carrier 2020 model that was installed new last year. Anything ese I can try before having to call a tech? short on cash. 1. I tested the 3 compressor pins and they all show OL. 2. I disconnected the compressor to see if breaker would trip without it and breaker does not trip, Fan Spins also.(This makes me think there is not an issue with Breaker nor contactor and maybe it is an issue with the compressor or wiring.) 3. Outdoor unit is very clean, and I dont see any visual wiring issues.
@holdway73
@holdway73 2 жыл бұрын
Following for ideas at my house. It was 100° in Reno today. 87° inside when I got home at 6:00pm. Supposed to be 95°+ all week 😵‍💫🥵☹️
@Drvanosdrand
@Drvanosdrand 7 жыл бұрын
You don't have both pieces on the truck ??? it's been leaking in the bucket for SEVEN years and you can't fix it NOW . Good video Steve
@sherwinalvarez7365
@sherwinalvarez7365 4 жыл бұрын
These people are amazing
@davidparker9676
@davidparker9676 9 ай бұрын
You don't have everything on the truck, you can't fix it today? You can't fix it all for less than $1000?
@WeatherNut27
@WeatherNut27 5 жыл бұрын
I was waiting for the "Boom" and was hoping the guy wasnt going to power it up too soon. Really Great video of both you guys on the job. He seemed like an ok guy.
@WeatherNut27
@WeatherNut27 5 жыл бұрын
Also wondering if the customer decided to use you for the new install
@bormorzx
@bormorzx 7 жыл бұрын
Thanks for all your videos!!! But I think the tonnage condenser unit u say "18" on this video minutes 1:12 is "24" 2 tonnage, right? model CK24-1B. Can u check again? And say hello for the dog. She or he is very famous Thanks
@pophamlarry
@pophamlarry 7 жыл бұрын
a whole new unit installed for under 1 thousand dollars? I'm laughing too hard! lol!! What century is that guy living in? 😂 that's just too funny to me.... great video Steve
@briancrane7634
@briancrane7634 7 жыл бұрын
Nice try Steve. While I was watching (great) vid I was trying to diagnose you went down all the paths that I would. But you can't start up a corpse. Thanks for the vid!
@yellowdeer7163
@yellowdeer7163 7 жыл бұрын
You can tell them the only way it will be less than 1000 dollars is to put a couple of rats in the squirrel cage. Done.
@blackknight5339
@blackknight5339 3 жыл бұрын
Unbelievable it took two Red Sox fans hours to figure out the compressor went bad. The HVAC guy didn't even put his tester on the compressor R,S,C to get a reading if he would have done that he would have found out the windings were bad causing the breaker to trip.
@hectorgalvan8674
@hectorgalvan8674 6 жыл бұрын
Half the problem is incompetent people.
@PaulDziomba
@PaulDziomba 7 жыл бұрын
Leaking in a bucket for seven years and he wants it fixed today for under $1,000.00! Bill him for your time and make sure your replacement cost includes a PITA fee.
@NytefogNJ
@NytefogNJ 7 жыл бұрын
i check run caps with a ESR Meter vs my fluke. it gives a more accurate Mfd reading as well the internal resistance using AC current vs DC from a multimeter.
@darrencarey8024
@darrencarey8024 5 жыл бұрын
Why do the inside coil have to be replaced unless its not compatible and totally out dated or maybe cant get just the coil if its leaking refrigerant and as far as it leaking water im sure the plumbing can be checked and if everything is fine jus blow out the drain with nitrous or some type of air with a little pressure and check if it is in need of a cap or should it be without it and see if it runs into some type of stack if clogged call a plumber. As for the compressor to me it is clearly grounded from what i see unless something is truly wrong with the breaker and or remove the breaker it self to see the condition behind it other than that lol damn thats a lot of money replacing both units ! ! ! !
@tomodell4092
@tomodell4092 5 жыл бұрын
At some point the old ass systrm needs to be replaced. That point was reached when the compressor got tired.
@ronniebuchanan6575
@ronniebuchanan6575 3 жыл бұрын
You buy a new oitdoor condenser R410A is all they make anymore which runs double the pressure of R22 refrigerant they are very proun to splitting the Evaporator coil. If you replace the compressor R22 then the cost of the gas a clean out kit or new line set you are at the same price. Then a month later the condenser coil splits tgen you are the blame.
@nickv4073
@nickv4073 7 жыл бұрын
"But I have a coupon!".
@davidparker9676
@davidparker9676 9 ай бұрын
Senior citizen discount? I've got a couple quarters for your time....
@noblesks5769
@noblesks5769 6 жыл бұрын
I’m just starting HVAC school and curious as to why it’s a whole unit/system replacement and not the compressor?
@mike203920
@mike203920 6 жыл бұрын
The cost of a replacement compressor would be almost as much as a new condensing unit. Also, the evaporator case is corroded and leaking. It just isn't worth it. I can understand wanting to save the customer some money, but you don't want to get carried away with that or you will get into trouble.
@ronniebuchanan6575
@ronniebuchanan6575 3 жыл бұрын
If you haven't figured the last part out R22 is unreal in cost. This is an old video but held true tgen.
@mpflood
@mpflood 7 жыл бұрын
Did you ever pull cover at comp. Pins?
@TONYTHETlGER
@TONYTHETlGER 6 жыл бұрын
I believe he did when he went inside the condenser coil housing. Check everything, assume nothing!
@anthonypera2746
@anthonypera2746 4 жыл бұрын
All that for a bad compressor nice taking notes steve
@rogerroger5585
@rogerroger5585 6 жыл бұрын
What gauge sheet metal is that?....Great video. I like the real time approach...constant cutaways are annoying
@donnierobertson3088
@donnierobertson3088 5 жыл бұрын
Great job again like always
@macster1457
@macster1457 7 жыл бұрын
no pawah mama, no pawah
@ericfelger
@ericfelger 7 жыл бұрын
Mac Pelao I was gonna make the same comment. Steve's videos are great, but his accent cracks me up.
@gregorysuarez7978
@gregorysuarez7978 6 жыл бұрын
Should check for acidic refrigerant at this point. The power to the disconnect should have been tested when returning from switching the breaker ON. Definitely before plugging the disconnect back in.
@TheOregonOutlaw
@TheOregonOutlaw 7 жыл бұрын
Damn fine video for "Diagnostics", and maybe a few Catholics too!
@blackknight5339
@blackknight5339 3 жыл бұрын
That was a bad video on a diagnostic check.
@benafluck
@benafluck 5 жыл бұрын
did vyou test the resistance of the C to RUN ..C to Start.. Start to Run..
@iLikeC00kieDough
@iLikeC00kieDough 5 жыл бұрын
He did around the 7 minute mark
@benafluck
@benafluck 5 жыл бұрын
just hang the power up to that unit you are fixing then check the voltage or put 220v Bulb if your getting a power to make sure.. so that the electrician can go and work..
@ravit6223
@ravit6223 7 жыл бұрын
@12.17 he says he heard "boom" @16.53 he says " i thought he said it was working". what could have happened ?
@edmundosantiago7372
@edmundosantiago7372 6 жыл бұрын
it's good or not to install a hard kit start to a new unit and why
@esecuate
@esecuate 3 жыл бұрын
I had the same issue today and I tried the same that you did also I thought that the compressor was bad but then I found out that the suction line was kinked up, that's why the compressor wasn't working.
@jerryforeman4543
@jerryforeman4543 6 жыл бұрын
Luv your mascot!
@junior_treyohfive
@junior_treyohfive 3 жыл бұрын
"under a thousand"😂😂😂
@Ron-oe7hg
@Ron-oe7hg 4 жыл бұрын
If you had open windings on the compressor then its automatically bad. Your being thorough, i understand but time is money my friend.
@davidparker9676
@davidparker9676 9 ай бұрын
He was trying to save this cheapskate some money. In the end it would have been better just to replace the unit.
@squadman3376
@squadman3376 2 жыл бұрын
Love that truck !!
@myutube1960
@myutube1960 5 жыл бұрын
So you are charging him for the service call, sell the guy a new unit plus installation and at the end of your video you call the customer a clown?
@imnotabotrlyimnot
@imnotabotrlyimnot 5 жыл бұрын
A bit tacky, eh?
@ronniebuchanan6575
@ronniebuchanan6575 3 жыл бұрын
He is giving them a quote on the job. Nothing sats he will get it. I can't work for free can you?
@henry9024
@henry9024 4 жыл бұрын
Steve’s the man!!
@jeffmoss26
@jeffmoss26 7 жыл бұрын
meeting of the minds, next level
@james8632
@james8632 6 жыл бұрын
what kind of gloves are you wearing?
@johnhpalmer6098
@johnhpalmer6098 6 жыл бұрын
Those are nitrile gloves, supposedly inert but work much like latex gloves and thus are not prone to be alergenic
@joeyburrell3207
@joeyburrell3207 4 жыл бұрын
No Powah is bad, but no money is worst, no powah or money, worse yet🤣
@gekkedirkie
@gekkedirkie 7 жыл бұрын
the hours that you need is almost 1000.
@guzman9011
@guzman9011 5 жыл бұрын
I was hoping it was the capacitor..
@1wtrahan
@1wtrahan 4 жыл бұрын
The guy didn’t check it he checked the wires , I would not have this guy work on my stuff , he wants to change out almost whole damn unit to make money not cool
@dadefope80
@dadefope80 7 жыл бұрын
@20:02 I don't blame you!
@Wakho007
@Wakho007 4 жыл бұрын
why not just replace the furnance to higher AFUE so that A coil can be added to new furnance with a bit conversion on duct. ?
@dwainbailey3223
@dwainbailey3223 7 жыл бұрын
Understand $1000? He got jokes lol 😂
@dannycalk8051
@dannycalk8051 6 жыл бұрын
Steve I have a question: My breaker to the ac keeps tripping, so I checked it and there was a mouse laying across the capacitor, so I replaced it ( fried mouse ) and the breaker still trips so what could be the problem. Is it possible that when the mouse shorted out the capacitor, it could have shorted out the compressor. Is the common and the herm terminals on different phases so when the mouse laid across them it caused a direct short between two phases.? . I haven't ohm ed out the compressor yet should I do that, or if it was a thermal protector inside the unit wouldn't it have reset by now, or would a direct short by the mouse cause it to not open? Help it's hot here in Texas.
@picklerix6162
@picklerix6162 6 жыл бұрын
Did you replace the mouse or the capacitor?
@holdway73
@holdway73 2 жыл бұрын
@@picklerix6162 New tech for 2022, mouscapacitors. The Three MousKepacaciteers! - a new movie about three renegade mice who fight for honor, justice and providing start up power for central AC units in Medieval times!
@davidparker9676
@davidparker9676 9 ай бұрын
@@picklerix6162 He replaced the mouse of course, he's got plenty of them in the basement.
@5332wonderboy
@5332wonderboy 3 жыл бұрын
Let me give this clown a bill? Wow! Some customer service my man. :)
@garytooker8664
@garytooker8664 5 жыл бұрын
Gloves???
@REWYRED
@REWYRED 7 жыл бұрын
Unfortunately, my condenser suffered the same fate last Thursday... Mind you it was manufactured in 1980.
@theairconditioningguy
@theairconditioningguy 7 жыл бұрын
You're going to need help with that coil. Let me know when you start the install so I can swing by and help you with it.
@MOUSEBOWEN
@MOUSEBOWEN 4 жыл бұрын
Awesome video
@GetMikeNyce
@GetMikeNyce 7 жыл бұрын
I had a my air handler capacitor go ,so no air was running over evaporator coil. refrigerant line froze up and i could hear a ' hiss ' coming from line at connection to air handler. I did not remediate low refrigerant issue and now breaker is tripping just like in this video and sounds like my condenser is blown. :(
@Jimmyd2hvacr
@Jimmyd2hvacr 3 жыл бұрын
How about maybe a shorted wire
@downtowngutter3875
@downtowngutter3875 5 жыл бұрын
I wish my maintenance program should me how to find shorts with multimeter. They just showed us ohms law. All book work
@davidparker9676
@davidparker9676 9 ай бұрын
You can get the rest of your training on youtube-University. Print your own degree.
@luisacevedo324
@luisacevedo324 6 жыл бұрын
So at the end of the day Sparky was right junk
@Fireship1
@Fireship1 7 жыл бұрын
Under a grand? Is he kidding! Lol. Where that coil is located we're talking extra just for the pain in the ass it will cause to remove and replace it!
@JohnDoe-jt9oq
@JohnDoe-jt9oq 5 жыл бұрын
@@throttlebottle5906 I've turned people down for that shit.
@scottk0623
@scottk0623 5 жыл бұрын
The sales tax will be under $1000 lol😂
@CoachTobyXL
@CoachTobyXL 4 жыл бұрын
Man if he would have touched MY unit lol 🥊
@MrLaffertyheating
@MrLaffertyheating 7 жыл бұрын
It's under 1000 for the service call & quote that's about it!
@caru3257
@caru3257 6 жыл бұрын
One of our electricians couldn't figure 240 in a condensor disconnect.
@jcc3279
@jcc3279 7 жыл бұрын
I have the same A/C unit installed on my house mine has been a champ just changed the start/run cap on mine because the old one failed still keeps the house nice and cool during the summer i do plan on replacing my old R22 system soon. Mine is from 1996 same with the furnace which is a Janitrol/Goodman GMP075-3 the A/C is the same model as that one CK25-1B my system is 20 years old roughly and works great just needs little things here and there most recent thing on the furnace was the blower fan changed it myself. Have a great one Jason C. - From Michigan and BTW the heat exchanger on the furnace was replaced 8 years ago because it was just starting to pop apart because of those crappy rivets that goodman used.
@gaybama5957
@gaybama5957 7 жыл бұрын
call me, i'll get a ya a nice new system for 15g's
@jcc3279
@jcc3279 7 жыл бұрын
Thanks anyway I already got a quote from a HVAC tech that is local who I've done business with for years.
@jcbecker28
@jcbecker28 7 жыл бұрын
That install is terrible. I wouldn't even install a used one for $1,000
@aircooledtx
@aircooledtx 7 жыл бұрын
Under $1k maybe for coil, but no condenser, condensate pump, line set and installation.
@Gears.and.Gadgets
@Gears.and.Gadgets 6 жыл бұрын
Funny it seems like the electrician was trying to cover his six. Under a grand.. I want to know what he is smoking.
@SOLDOZER
@SOLDOZER 6 жыл бұрын
No powa. No powa......
@JustPlumDucky
@JustPlumDucky 7 жыл бұрын
What exactly was causing the problem?
@tomodell4092
@tomodell4092 5 жыл бұрын
Compressor was stuck. Overloading the breaker. And...breaker was probably weak too. Bottom line, bad compressor.
@JCHD18CVOLim
@JCHD18CVOLim 7 жыл бұрын
Can you install it today? Will it be under a $1,000.00? HaHaHaHa
@TONYTHETlGER
@TONYTHETlGER 6 жыл бұрын
Exactly why he said "Let's give this clown a bill and get outta here". Loved it!
@sherwinalvarez7365
@sherwinalvarez7365 4 жыл бұрын
I wouldn't even do the install. Let him find the guy that does it less than G, and ill take the service calls cleaning up his work. Hopefully they are all Sunday and 90° out.
@copkhan007
@copkhan007 5 жыл бұрын
Let me give this Clown ( Customer ) the Bill and get out of here.....Steve, Be Nice
@garyglanz403
@garyglanz403 5 жыл бұрын
He seemed to know the customer was playing him.
@1wtrahan
@1wtrahan 4 жыл бұрын
Wow let me get this clown a bill really , the customer was right and all was needed was a condenser .you have to match a condenser with old coil size ,install ,charge unit, for 950.00 , the whole condenser unit is only 375.00 complete , it’s actually cheaper then just installing a bad condenser pump. You boys sure getting people .
@ronniebuchanan6575
@ronniebuchanan6575 3 жыл бұрын
Have you ever seen an R22 evaporator coil split when hooked to a R410A condenser? They are actually phasing out R22 units and compressors. The cost of the R22 is unreal these days.
@lzgamer8133
@lzgamer8133 3 жыл бұрын
22:14 is the close
@realestateservicessaleshea99
@realestateservicessaleshea99 4 жыл бұрын
🤡 Lmao Man I though it was me!!!🤣😂🤣🥃🥃🍺🍺 Stay safe. Retired keyboard super tech. Wear your safety glasses.
@pierre_wepener
@pierre_wepener 4 жыл бұрын
No Powa!!! We've got it!
@hvacsoldier1554
@hvacsoldier1554 7 жыл бұрын
Does anyone know why the disconnect was wired that way?
@JohnDoe-jt9oq
@JohnDoe-jt9oq 5 жыл бұрын
Alcohol was a factor.
@vppnbrent
@vppnbrent 6 жыл бұрын
Everything about that wiring was scary.
@jimford01
@jimford01 7 жыл бұрын
You ever succeed in smacking compressor with a piece of wood or hammer. when it's stuck like that.
@rrcoster
@rrcoster 4 жыл бұрын
LOL got love customers under $1000 good one.....maybe x3
@knightrichson8031
@knightrichson8031 5 жыл бұрын
my ac will trip when unit is off i never seen that before
@blakehollingsworth839
@blakehollingsworth839 4 жыл бұрын
knight richson Sound like you have a loose connection at the disconnect.
@ryans413
@ryans413 7 жыл бұрын
Funny how the electrician comes and tries to cover up that he made a mistake
@Casualgaming763
@Casualgaming763 6 жыл бұрын
No Powwa fo sure
@mrolfe8341
@mrolfe8341 7 жыл бұрын
I can tell you like a challenge!!
@jaycase8545
@jaycase8545 7 жыл бұрын
Couldn't you just replace the compressor with a same one instead of getting installing a whole new refrigeration system?
@WILLRS85
@WILLRS85 6 жыл бұрын
Jay Brod R22 refrigerant are expensive. And those outdated compressor are phased out.
@Josh-px6xb
@Josh-px6xb 6 жыл бұрын
Yup might as well get a new unit cause it’s gona cost almost the same
@WILLRS85
@WILLRS85 6 жыл бұрын
I can't see the factory charge well, look to be 71oz? That's about 4.5lb, R22 is $100/lb 👀👀👀
@findme5270
@findme5270 7 жыл бұрын
That's a 2 ton btw
@jchambers2586
@jchambers2586 6 жыл бұрын
I have the same unit it still runs
@thechyctech5636
@thechyctech5636 4 жыл бұрын
i believe it said 18 which i a ton and a half a two ton would say 24
@thechyctech5636
@thechyctech5636 4 жыл бұрын
my bad, he read it out loud wrong. I looked again it is a 2 ton, lol
@gerardosegobia4050
@gerardosegobia4050 4 жыл бұрын
Hate this type of service where nothing turn on you get power then you dont... electric problem been there it's the worst
@FredD63
@FredD63 2 жыл бұрын
HaHaa under $ 1000. Step into the next century ..
@amtraktraveler9118
@amtraktraveler9118 5 жыл бұрын
Unplug that Focker!!
@Spector_NS5_RD
@Spector_NS5_RD 7 жыл бұрын
great try Steve. BTW that's a 2 ton (model# CK24-1B). i just sold one from my backyard condenser boneyard for $100 to a guy last friday :) fuck running a new lineset. if that one is isn't leaking it's getting used....
@bradhvac5866
@bradhvac5866 7 жыл бұрын
You should never use the old line set Poe oil doesn't mix with mineral oil. There is no way your going to blow all the oil out with nitrogen. You would at least have to use a flush kit.
@joshuapoche5137
@joshuapoche5137 7 жыл бұрын
Brad Hvac thats what they said when they first started using poe oil but thats not accurate now. we were having a problem with swapping to 407c so we had a refrigerant rep come to our company to explain how we should be doing the swaps. he said their having problems with oil return with poe oil so we need to add 10% mineral oil to system to get the oil to return. just another thing these companies rushed to market thats screwing us now. we loose a lot of compressors now
@gilianrampart8514
@gilianrampart8514 7 жыл бұрын
Brad Hvac POE does mix with mineral oil.
@Fireship1
@Fireship1 7 жыл бұрын
billybassman21 I've done the same countless times and never had an issue. Some of those units I've installed have been running for years now.
@Fireship1
@Fireship1 7 жыл бұрын
Spector NS5 RD no reason to replace them if they don't leak. Even on a burnt out system you can flush them and then install a suction line filter for extra peace of mind. I've replaced a few that were kinked excessively or damaged in multiple spots. Otherwise they getting reused!
@theamerican7131
@theamerican7131 7 жыл бұрын
Enjoyed the video. Thumbs up.
@WilliamWBG
@WilliamWBG 4 жыл бұрын
2 wire piece of shit hard start.. come on Lav. You probably charged $225 for that shitty Hard start
@mikepaquette5680
@mikepaquette5680 7 жыл бұрын
Good vid Steve that guys on drugs with that price. Maybe the overload is what was tripping the breaker when the compressor over heats from not starting....What you think?
@donnierobertson3088
@donnierobertson3088 4 жыл бұрын
Good
@MrRastephen
@MrRastephen 4 жыл бұрын
It shorted to ground dude
@terryreyes1125
@terryreyes1125 6 жыл бұрын
Looks like a very dishonest electrician. He knows he didn't even check and just said "direct short" 🙄
@michaelleddy3701
@michaelleddy3701 4 жыл бұрын
When ever you get half sentences and they hope you finish so he can say yeah and agree. Haaha
@profuse007
@profuse007 7 жыл бұрын
Sounds like inconclusive withe compressor diagnostic
@brianw8411
@brianw8411 3 жыл бұрын
What a clown… under $1000 he says.. does he think he’s a comedian or something?
Solving the Mystery of a Non-Cooling Goodman AC Unit
22:39
steven lavimoniere
Рет қаралды 20 М.
furnace blowing low voltage fuse when a.c. runs
26:50
steven lavimoniere
Рет қаралды 180 М.
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,4 МЛН
OLDER AC SYSTEM TRIPPING BREAKER
7:57
steven lavimoniere
Рет қаралды 12 М.
2 No Cooling Calls.  Freeze Up, Breaker Tripping!
24:26
Jeff’s HVAC Adventures
Рет қаралды 3,2 М.
AC Keeps Tripping Breaker and The 10 Most Common Reasons Why
12:34
Word of Advice TV
Рет қаралды 556 М.
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 677 М.
AC UNIT NOT COOLING DOWN HOUSE
9:23
steven lavimoniere
Рет қаралды 12 М.
AC Not Working... Contactor Not Getting VOLTAGE
10:02
Sam
Рет қаралды 308 М.
PILE OF YORK AC SYSTEM ICING UP
7:34
steven lavimoniere
Рет қаралды 15 М.
A/C Troubleshooting - Compressor AND Fan Won't Run
8:39
Apartment Maintenance Pro
Рет қаралды 17 М.
Testing if an HVACR Compressor is Shorted to Ground, Open, or Overload Tripped!
11:06