Can a One Way Drier be Used in Reverse?

  Рет қаралды 5,536

HVAC Shop Talk

HVAC Shop Talk

Күн бұрын

HVAC Shop Talk is a KZbin channel that celebrates the guys and girls in the skilled Trades - especially HVAC. In this video I test a one way filter drier to see how well it works in reverse. #HVAC #Filterdrier #HVACtraining
Links to all my social media - linktr.ee/Zack...
Support the channel at SubscribeStar - www.subscribes...
Sponsor Links
Yellow Jacket - yellowjacket.com/
NAVAC - navacglobal.com/
Refrigeration Technologies - www.refrigtech...
Company Cam - companycam.com/
EWC Controls - ewccontrols.com/
Tru Tech Tools (Use SHOPTALK discount code) - www.trutechtoo...
Contact me - hvacshoptalk@gmail.com

Пікірлер: 33
@Bobherry
@Bobherry 2 жыл бұрын
Please do a biflow heat pump dryer and a suction line dryer
@Josephpono
@Josephpono 2 жыл бұрын
The HVAC guy installed one way filter drier on my 5 ton heatpump. It never worked right for over a year and really struggled. Anyway a biflow filter drier was installed. I also changed out defrost control with a universal Honeywell. Since then my central heatpump works great. I was scared the unit was damaged with wrong filter drier. It doesn’t seem to be.
@tjmaseym
@tjmaseym 3 ай бұрын
Thank you I needed this
@EverythingHVACR
@EverythingHVACR 2 жыл бұрын
Interesting test, Nicely done Zack 👏. I have seen some installed backwards in the field and working, curious to cut open a bi flow and see the difference.
@HVACShopTalk
@HVACShopTalk 2 жыл бұрын
Will get a bi flow
@markodivkovic5353
@markodivkovic5353 Жыл бұрын
Great video. If you install a filter drier so the liquid flow is correctly when the gas comes in other way in reverse mode it should not be a problem at all.
@ishalljr
@ishalljr 2 жыл бұрын
Do a bi-flow
@HVACShopTalk
@HVACShopTalk 2 жыл бұрын
Will do
@universalservicetechust3578
@universalservicetechust3578 2 жыл бұрын
One was installed backwards on a walk in cooler, it stopped working in a couple of days, I went back and the filter was oil logged, I put a new drier in and new refrigerant, that was 3 years ago, definitely made a difference in this case.
@HVACShopTalk
@HVACShopTalk 2 жыл бұрын
Do you remember the brand of drier? Maybe it was constructed differently
@universalservicetechust3578
@universalservicetechust3578 2 жыл бұрын
@@HVACShopTalk it was a sporlan
@HVACShopTalk
@HVACShopTalk 2 жыл бұрын
Thanks. It would be neat to see how they model was built.
@PitfallHarry72
@PitfallHarry72 2 жыл бұрын
I imagine that at first it would be okay, especially on a new system, but over time it could become a problem, progressively degrading performance/efficiency.
@lariosfregosoify
@lariosfregosoify Жыл бұрын
Needed this
@heavydiesel
@heavydiesel 2 жыл бұрын
Think the main issue is theres no filter pad at the inlet so if the flow is backwards bits of the core could make it into the system.
@OcRefrig
@OcRefrig 2 жыл бұрын
Yea, my thoughts too. thats the reason i dont use Sporlan driers. i dont like the solid blocks they use they break apart. especially if drier gets dropped in shipping. i only use Emerson / Alco. they use Lots of tiny dessicant beads that dont break or dust up. Much Quicker Moisture removal and larger surface area overall. also if drier is dropped beads dont break. sporlan cores do.
@heavydiesel
@heavydiesel 2 жыл бұрын
@@OcRefrig Our local wholesalers have stopped stocking Sporlan stuff and switched more to Danfoss, they have the same style solid cores but so far have had good luck with them.
@kennethmaki9255
@kennethmaki9255 Жыл бұрын
No it will not work. I just found a system with the drier wrong way. It might work the first days but after a while it will stop working. And also someone said the desicant inside will get out in the system.
@jaredbeaulieu6612
@jaredbeaulieu6612 2 жыл бұрын
I don’t know if the results would be different but vapor is never flowing through the drier when the u it is operating properly. It is a liquid line drier, even a heat pump in heating there will be 100% liquid refrigerant flowing through the drier. Like I said I don’t know you flowing vapor nitrogen verse a liquid is giving you false test results, but it might be worth trying again with like water or some thing like that.
@wasimedoo7994
@wasimedoo7994 2 жыл бұрын
Very good information bro
@jerrylockhart3069
@jerrylockhart3069 2 жыл бұрын
Cut open a biflow drier and see. I might do it one day.
@webstermckinney6893
@webstermckinney6893 11 ай бұрын
Why not use a flow metter at both ends of the drier? Then reverse an check what the drop is? Also is it diffrent at difrent pressures?
@madisonhvacr1562
@madisonhvacr1562 2 жыл бұрын
I notice in 15 min pressure like having restriction or bad expansion Valve
@braintumor943
@braintumor943 2 ай бұрын
Dude, The problem is that screen, that stone will come apart , if it’s in right, you’ll never know, if it’s backwards, you got issues
@jerrylockhart3069
@jerrylockhart3069 2 жыл бұрын
That’s what I’m gonna say because it gradually getting slower and slower even if you had a massive bottle it would keep dropping slower and slower. I don’t think it causes trouble the only thing you can do is try it on a real system while it’s working. That would take the cake.
@scottjones7279
@scottjones7279 2 жыл бұрын
I am not going to test it not enough time to go back and fix it
@clayfree7428
@clayfree7428 2 жыл бұрын
Once the filter starts loading up with system contaminates ……it will be like putting a house fire out with a McDonalds straw.
@HVACShopTalk
@HVACShopTalk 2 жыл бұрын
Seems difficult
@AustinAudiS6
@AustinAudiS6 2 жыл бұрын
Liquid freon will react differently than gas nitrogen.. pointless test.
@stephwaylonwells3218
@stephwaylonwells3218 2 жыл бұрын
👍
@jackmen4
@jackmen4 2 жыл бұрын
Yes you can…… will the outdoor unit last long……. Nope. Two or three years max
@xXxFLYMODE69xXx
@xXxFLYMODE69xXx Жыл бұрын
Have you seen this happen firsthand? I had a keeprite furnace and 1.5T A/C Unit installed in 2021. I went 2 seasons with it working beautiful, it was the best A/C I ever experienced. 2 years later upon first start up in 2023 I had no cooling, we spent the whole summer diagnosing it. We found that the filter drier is backwards and now my compressor is working at about 60% capacity and my energy bill is double what it was the previous year. I suspect most of the problems stemed from the backwards filter drier.
@realestateservicessaleshea99
@realestateservicessaleshea99 2 жыл бұрын
It's to keep the trash inside when or if it starts to break down. Thanks again for the videos. 🍺🍺🍺🥃🥃🎯🏌🏻‍♀️ Stay safe. Retired (werk'n)keyboard super tech. Wear your safety glasses!
HVAC 070 Suction line Filter Drier
14:04
Love2HVAC with Ty Branaman
Рет қаралды 18 М.
Replace HVAC Drier
22:36
The HVAC Life
Рет қаралды 32 М.
Офицер, я всё объясню
01:00
История одного вокалиста
Рет қаралды 6 МЛН
The selfish The Joker was taught a lesson by Officer Rabbit. #funny #supersiblings
00:12
规则,在门里生存,出来~死亡
00:33
落魄的王子
Рет қаралды 28 МЛН
Forced-air Furnaces: The What, Why, and How
22:05
Technology Connections
Рет қаралды 1,3 МЛН
EK Liquid Line Filter Drier - Demonstration
3:06
Copeland
Рет қаралды 70 М.
HVAC: DIY Goodman Install: Can this unit be saved?
34:28
ComfortPlus Heating and Cooling
Рет қаралды 187 М.
What the A/C filter-drier can do
5:01
grayfurnaceman
Рет қаралды 49 М.
How Filter Driers Work - HVACR
8:01
The Engineering Mindset
Рет қаралды 158 М.
Change a 13 yr old drier filter part 1
21:49
Jim Pettinato
Рет қаралды 41 М.
How the AC Receiver Drier and the AC Accumulator Work
6:10
HOWSTUFFINMYCARWORKS
Рет қаралды 83 М.
How to change a drier filter
4:18
David Allegro
Рет қаралды 7 М.
All HVAC Guys and Gals Near to Hear This
9:16
HVAC Shop Talk
Рет қаралды 1 М.
Офицер, я всё объясню
01:00
История одного вокалиста
Рет қаралды 6 МЛН