It would be nice to see what happens if the smaller battery reaches the bottom. Can you still use the remaining capacity of the larger battery? What is the BMS doing while the smaller battery is at 0 percent? How is the recovery process working when charging again up to 100% ? How do you handle the error messages from the smaller bms since the errors are "normal" compared to a real battery problem?
@griffinsBuilds3 ай бұрын
Hi mike's, I discussed some of this in the video when looking at the charts plotted from home assistant. The batteries would likely reach 0 percent around the same time (due to when the voltages gets lower on the smaller battery much more currently will flow from the larger battery) And they also fully charge and reach 100 percent at the same time. I don't get any error messages from either bms. Thanks for your comment
@ygreq3 ай бұрын
A tutorial about integrating the jkbms in HA would be great
@griffinsBuilds3 ай бұрын
I might consider doing that in future. Thanks!
@jec_ecart3 ай бұрын
Yes it works.. If properly matched.
@Sylvan_dB3 ай бұрын
Sure, parallel is fine. Doesn't need any smarts to do that, and sometimes smarts will screw it up.
@offgriddreaming540326 күн бұрын
Hi mate. Interesting. Im doing the same at the moment with 160 ah of CALB cells with batrium bms and 105ah eve cells with seplos bms. I'll have to make a vid of the setup Cheers
@ticknguyen3 ай бұрын
We can connect two JK communication systems, and the management unit will regulate according to the discharge rate, for example, discharging at 0.2C proportionally for two different capacities. Please connect via IJ communication and experience it.
@griffinsBuilds3 ай бұрын
Hey mate, what do you mean by management unit? Do you mean BMS? jk bms don't have current limiting, they do have overcurrent protection though.
@ticknguyen3 ай бұрын
"I'm currently using the BMS JK JK-PB2A16S-15P." ->Can rs485 to can 485
@griffinsBuilds3 ай бұрын
oh ok yeh thats an JK inverter bms. I personaly dont want to bother with communication between the inverter and BMS. The inverter bms doesnt have current limiting so they dont actually regulate the discharge current, the battery voltages do that automatically so its not needed anyway. Also when you using a victorn system with a venus os on raspberri pi or cerbo gx if for whatever reason your pi or gx fails your inverter will also stop discharging or charging. If you just let the inverter calculate capacity it will keep running even when your cerbo fails when running off grid. Andy from off grid garage has also discussed this. I have been running mine for months now with no communication and it all works fine. Also the inverter bms is much more expensive, so not worth it for me really.
@ticknguyen3 ай бұрын
@@griffinsBuilds I carefully reviewed your video. Currently, you're using the JK model, which lacks communication capabilities. We should consider discussing an upgrade to the IK model with communication features. This would be beneficial, though it may involve significant costs. I hope this is a helpful personal suggestion
@griffinsBuilds3 ай бұрын
@@ticknguyen yes that's correct! I just explained the reasoning for this on the above comment.
@mrschmiklz3 ай бұрын
Was the jkbms easy to add to HA? I have some victron components without a cerbo gx and it was close to nightmare to get all the data in.
@griffinsBuilds3 ай бұрын
Yes its fairly easy, just need to use the batmon addon. It scans for bluetooth devices and you then just put in the bluetooth address of the jk BMS and it reads everything.
@eduardofernandez52173 ай бұрын
No, the answer is NO, you wouldn’t be able to use all your capacity
@griffinsBuilds3 ай бұрын
Actually, I can use all the capacity, as explained in my video.