Short video of the faulty capacitor cut open: facebook.com/jwflame/videos/320897598422229/
@aspudkicker7 жыл бұрын
It makes me wonder the quality of the capacitor when the core is that far off center, as the core will have greater insulation to the outside in some places compared to others. If they cant be bothered getting the core somewhere squared, what else haven't the manufacturers been bothered with and cut corners?
@smartchip5 жыл бұрын
can a failed capacitor cause a rcd to trip?
@Dime_Bar7 жыл бұрын
How about a follow up video on how capacitors work on motors.
@timallen60253 жыл бұрын
Perfect , ‘ we can do’, testing , understanding the testing and SAFETY . Top teaching empowerment thank you JW
@combie816 жыл бұрын
Well what would you know...... Just watched this on the 1st and my tumble dryer packed in yesterday and the cause after some simple testing... the capacitor for the motor :) Thank's John - new one ordered and to be fitted tomorrow :) For those interested: White Knight CL 447WV Symptoms - No grinding noises/bearings smooth/drum not locked up/belt intact/timer/heating element all work fine and motor powers up but no spinning drum. If you give the drum a little push start it works as normally, when drum stops to change direction it wont spin again without a nudge. Fix - Replace motor capacitor
@ianmaynard6222 Жыл бұрын
My sun bed has a missing 240v 50 uf capicitor missing. Ive bought another but the wires coming out of it are both white yet my sunbed has a brown and blue wire to attach to it. My question is how do i know which wires go where? Thanks in advance
@jwflame Жыл бұрын
Brown to one of the white wires, blue to the other white wire. Makes no difference which one, it's AC.
@marhar2 Жыл бұрын
Excellent video! @11:17 could you explain this further and provide a demonstration?
@TheEulerID5 жыл бұрын
Something else that is very important is that it's an AC rated capacitor and not a DC electrolytic as the latter will fail catastrophically using AC. Of course they are unlikely to be confused as a DC 450v electrolytic of that capacity will be much smaller and look rather different, but just in case...
@Smudgie3 жыл бұрын
Are there any precautions to take when re-connecting a capacitor?
@Robonthemoor6 жыл бұрын
I’ve just found JW the best on KZbin fantastic delivery keep em coming I can’t get enough 👍
@DrGreenGiant6 жыл бұрын
Safety point about supercapacitors; if you short it to remove the voltage then leave it for a while, it may restore its charge. Leave them shorted!
@metaxa7157 жыл бұрын
John it is always a pleasure to watch your videos! cheers!
@andreim8417 жыл бұрын
Had one give up the ghost last week in a central heating boiler pump. There was no leaking or deformation in the cap, but that's not unusual in this type of poly caps. One thing worth mentioning is the fact that if the cap is blown, in some cases the motor will draw more amps and fry itself.
@bobrose79007 жыл бұрын
Well done John, useful information and great presentation. I have the benefit of a private water supply and multi stage single phase borehole pump some 88m below ground. I forget the startup capacitor value but they are like bake bean cans (excuse the phrase!} and when they periodically blow they usually explode leaving a large hole in the side of the case! 37A startup current would account for this. An explanation of the circuit would be useful and the considerable advantages of 3 phase motors - now available by using an inverter in this scenario.
@davidfildes98267 жыл бұрын
With an old analog meter can test if open or shorted. Using continuity (resistance) apply to terminals then reverse a good capacitor will kick the needle....Good idea to short capacitor before removing from motor.
@jimraq16 жыл бұрын
Great video. Thanks for posting.
@maldridge7630 Жыл бұрын
does the list of uses also include house gate motor capacitor? Are those also considered single phase electrical motors?
@stevenbroadbent54172 жыл бұрын
Great upload John. Thank you.
@davidfildes98267 жыл бұрын
Just a note: some motors have an auto reset thermal cut off to prevent burnout caused by a pump running dry etc. Worthwhile waiting for possible reset before checking capacitor.
@Berkeloid05 жыл бұрын
At 2:50 you say that the voltage rating printed on the cap is the peak voltage of the AC waveform, but doesn't the little squiggle/tilde in "V~" mean "volts AC"? Which would suggest to me that the printed ratings are the RMS values rather than peak. Are you able to confirm this? If I understand you correctly then finding a cap rated at 240 volts AC won't actually work on 240 VAC because as you say the peak is nearer 340 volts. I would've thought a cap would be rated at either 240 VAC or "AC, 340V peak". Every other AC component seems to be rated at RMS voltages and I've never heard capacitors as an exception so if that's true it's a surprising one that isn't talked about much!
@jkbrown54965 жыл бұрын
I just went down the rabbit hole on this for run capacitors like the ones shown. I discovered that the voltage rating on a run capacitor is for the back EMF, not the supply voltage. Back EMF can get quite high even for a motor driven by say 120v mains and is dependent upon the motor speed. Running a motor without a load thus at highest speed cause the highest back EMF and can shorten the life of the run cap.
@Berkeloid05 жыл бұрын
@@jkbrown5496 Very interesting! How difficult is it to figure out how much back EMF you're dealing with?
@BenjaminGoose6 жыл бұрын
It's important to remember to short the capacitor twice, since after first shorted it can recover some of its voltage.
@telwood155 жыл бұрын
he already showed that.
@bbjazzmanjazzman77213 жыл бұрын
Rewatch the video and use your EARS!!
@MrKwelsh2 жыл бұрын
John my pressure washer pump, isn't working and us very warm. When I turn it on it humms. Do you think if the capacitor isn't working it would cause tge pump to overheat?
@cuckingfunt93537 жыл бұрын
The 'rating' is the voltage, the capacitance is the value
@omarhadjarab80492 жыл бұрын
Using this Fluke(same as mine) and a Robin won't be enough to determine the health of a capacitor even if you get the correct capacity (Farads) when measured. What you need in reality is an ESR meter to meausure the Effective Series Resistance, if it within the proper value the cap would be good and the machine would work efficiently, or else, many bad scenarios could take place, fire, damage to motor, fried PCB, or even electric shock in some instances.
@philnoel58394 жыл бұрын
John, I have to replace both capacitors on my Drill Press. The only thing that i am not sure of is, Does it matter which wire to use ?. Both capacitors have 2 black wires . but, The motor wires are red and black for the run capacitor. And red and blue for the start capacitor.
@jwflame4 жыл бұрын
AC capacitors can be connected either way, there is no polarity.
@adrianTNT2 жыл бұрын
To make a 220V motor spin slower, do I need a smaller capacitor than original, or a larger one ? And does it directly multiply ? E.g a half or a double size capacitor would give half or double the motor speed ?
@gassanali86674 жыл бұрын
What does resistance value denote in these tests? Is it mean that the capacitor is not internally shorted and the resistance between its dialctrics are according to the specs?
@longrunner2587 жыл бұрын
There is an error in this video regarding the voltage ratings: While it is true that the peak voltage of a sine wave is root-2 (1.414…) times the RMS level, capacitors purpose-made for AC applications (like these) are rated in RMS volts (so their DC limit will be higher). Motor capacitors have their high ratings because the phase shift can subject them to *more than* the input voltage.
@someonesomewhere12407 жыл бұрын
Yup, a 500VAC cap is good for about 700VDC. And this means that you **must not** use a 250VAC capacitor to start a 230VAC motor - the capacitor will have 300VAC or more, because the start winding is highly inductive.
@smartchip5 жыл бұрын
can a failed capacitor cause a rcd to trip?
@jwflame5 жыл бұрын
Only if it causes a fault to earth, which in most situations is unlikely.
@smartchip5 жыл бұрын
@@jwflame ok, thanks for replying, i think everyone has been there, stuck on a " can this be the problem.... " hope running lean, the brummie shall look at the two coils, delta and y, thanks again bud,
@unobianconero57514 жыл бұрын
for 3 wire ac motor with single capacitor, should we plug the com to neutral, 2 others from motor plus live to capacitor or changing the live and neutral or it makes no difference?
@tetrismk5 жыл бұрын
Hello thank you for your video. I have a bad capacitor on my old sewing machine on the motor with rating 0.1nF + 2x 2500pF. It is hard to find new with same rating. Any help on how to replace it? Thank you
@williammcgrattan95837 жыл бұрын
JW always makes it easy to understand, 👍. Brilliant
@KrisX73317 жыл бұрын
What about start up capacitors?I've seen quite a few in old electric motors.They have odd values like 134-156 uf.Can you explain what are they about?
@TK421386 жыл бұрын
Would a failed motor capacitor cause a single phase AC motor to trip out the electrics when motor is switched on?
@jwflame6 жыл бұрын
Not usually - it would have to fail short circuit to do that, and capacitors of that type should be designed to fail open circuit, in which case the only problem is the motor does not start.
@TK421386 жыл бұрын
John Ward Thanks for replying. I have a feeling I've got a duff motor.
@mts72742 жыл бұрын
I'm guessing any digital multimeters under $20 is unable to check the MFD level of a run/start capacitor. Is that correct. None of the one's I've seen have all the options/settings that your meter has.
@jwflame2 жыл бұрын
Most under $20 meters won't have that capacitance range, you will need to look at $50+ for those that have it. Something like the UT139C made by Uni-T. The meter in the video is a Fluke 117, which is about $250.
@mts72742 жыл бұрын
@@jwflame You just made me cry...
@warrengray6107 жыл бұрын
Hey John I wonder if you can help with a question on motors
@patprop747 жыл бұрын
i have a box of fifty of these from taking apart pool pumps for copper wire recycling, Do you have any suggestion for something useful to do with them ?
@jwflame7 жыл бұрын
Not really - no one will want used capacitors as new ones are so cheap.
@chrismallatratt84527 жыл бұрын
Another fantastic informative video. Thanks J.W.
@squaidinkarts5 жыл бұрын
Thank you! You're great at explaining
@petermelville9316 жыл бұрын
Very interesting video, thank you. I have a large 1000 microfarad capacitor and when I try insulation test at 500V, the meter struggles to go over about 40V and shows a low resistance reading. I thought it had a short in the capacitor but I am now wondering if the insulation tester is struggling to make sufficient current to charge the capacitor, and the capacitor itself may be ok. I also have a capacitance tester but it doesn't have a setting for capacitors this big.
@groovejet772 жыл бұрын
240v peak to peak is 480v right?
@JakeKennes6 жыл бұрын
Hi Mr. Ward, Very educational, thank you. My Riello 40 Oil burner has a 90W motor with a capacitor of 4uF, which was no longer working, so I repalced it with a capacitor of the same value, which lastet about 2 months; replaced it again with on of 4uF, which lastest another month. Now repalced it with a capacitor of 12uF. Hopefully this one will hold... But my question is: will this capacitor 12uF now damage the engien; is it bad to use a different capacitor value and why? Thank you, Jake
@anonymusptbo87045 жыл бұрын
Jake Kennes Your capacitor exploded due to a fault in the circuit, or a voltage rating lower than the supplied voltage. Changing it for one of a different Microfarad value will not help that. Use a 4 microfarad with a higher voltage rating. However the 12 microfarad capacitor will not damage your motor, only worsen your power factor
@MartinJG1006 жыл бұрын
John. I have a prob with my lawnmower. It's been getting harder to start and appears to produce less torque over time. First noticed this last year in the spring. More noticeable with longer grass of course but is less of an issue as the season progresses and grass growth slows. It has now packed up. This has all the symptoms of a failing capacitor. The safety breaker switch also trips when it is switched on. I only have a circuit tester which is of limited use but I decided to replace the capacitor anyway. No success. I have checked all the cables and they are fine. Is it possible the motor has packed up? If so, what is the easiest way to test it? Don't want to replace the mower if it is fixable. Many thanks. PS - Think it is @ 8 years old but has had a relatively easy life.
@jwflame6 жыл бұрын
Motor failure is certainly possible, and could result in the same symptoms. The breaker tripping when switched on suggests some fault with the motor itself such as failed / shorted windings. If it was just the capacitor failed, it would not trip.
@MartinJG1006 жыл бұрын
Thanks for getting back, John. That's what I thought. Did another circuit test (based on the old joiner's adage of measure twice not once!) and everything is fine up as far as the motor. Funny thing is I get a reading on both wires at the mains 'in' end but only via one motor wire, if that makes sense, which suggests a short somewhere. Trip would confirm that. Seems your hunch about the windings could well be right in which case it is game set and match. Time for a new mower before the Triffids move in. Many thanks. PS - Great channel for us part timers.
@johnlbales27737 жыл бұрын
I'm hand building low voltage DC motors. What is a good starting capacitor diagram so that my motors are self starting? Thanks.
@Coolkeys20097 жыл бұрын
DC motors are normally self starting, no capacitor needed.
@johnlbales27737 жыл бұрын
Coolkeys2009 Thanks. After I wrote the question, I started thinking that AC motors use them. I just don't want to put power to it because I don't want to burn insulation off the magnet wire. Guess it's time to creep up on the voltage and see what happens. I wanted to prevent problems by making mistakes on paper first. Obviously I'm a total noob. I've tried 3 different rotor designs, but only have had a few AA or 9V batteries. Barely able to detect a response with a neodymium magnet. I've got good continuity thru the coils & commutator contacts. I wrote the lack of response off to low power issue. I just purchased a DC power supply 0 to 30V and 0 to 5A. I really don't want to screw that up. It was a big expense, especially at the end of the month. (Thanks to my sister who helped.) And again, thank you for your response.
@Coolkeys20097 жыл бұрын
You could measure the resistance across the commutator and use Ohms law I=V/R to determine the voltage that will drive the required current through your windings(at 0 RPM). The maximum current will be determined by the thickness of wire you have used. Once your motor starts spinning it will require more voltage as it speeds up to keep increasing in speed. A PSU 30V 5A is a 150W and can easily destroy stuff connect to it and maybe it's self, so I would start of by keeping the current set low 0.1 to 1amp and the voltage bellow 10V. When working with inductive/low resistance loads it's easy to damage regulated psu's, so I would also watch for abnormal readings and behaviour of your psu when your motor does start spinning. Wiki pedia has good in basic information on all kinds of motors. I have made a few videos about my experiments with Brush less DC motors.
@3D_Printing7 жыл бұрын
Don't test a circular saw with a finger, even if it is weak
@Synthematix7 жыл бұрын
What about noise suppressor motor caps
@daniellambrou68484 жыл бұрын
Can a capacitor trip an RCD device?
@MrAtheHun7 жыл бұрын
Great tutorial thank you, a couple of months too late for me regrettably. One thing I couldn’t get to the bottom of when I was looking this subject up is. Can you damage the Capacitor by shorting it?
@jwflame7 жыл бұрын
It's probably possible but very unlikely.
@ParaglidingManiac6 жыл бұрын
I remember one of these exploding in my face. Now it's over 20 years later, I'm a high-end engineer, but still afraid to get near them or hold them in my hand:)
@robbieaussievic6 жыл бұрын
........ That vase is Ming Dynasty 1368, a rare black limited edition stolen by Mongol invaders who used it to store bi-polar 25uf capacitors until 1644.
@tailor42024 жыл бұрын
E-bike battery 60v 20 ah 1500w. Wich one capacitor I need for this bike? All information please. I do not know abaut that Tell full info and size Thx
@waynejohnson64417 жыл бұрын
Have you seen the new fluke t6 john
@michaelcostello69917 жыл бұрын
Do you need to disconnect both ends of cap from circuit before testing. Both the insulation test and capacitance ??
@heavydiesel7 жыл бұрын
You only need to disconnect one side of the capacitor from the circuit to test its capacitance.
@TaramaniRai-q8z9 ай бұрын
What is model of multimeter?
@jwflame9 ай бұрын
Fluke 117
@AnonymousPacifist7 жыл бұрын
Good way to test capacitor banks?
@johnsimpson82637 жыл бұрын
You will need to disconnect the capacitors from each other.
@toysareforboys17 жыл бұрын
That sucks :( I got a bank of 5 caps, but when I try and start charging the bank, one cap starts to go reverse polarity :( I don't have a 3v power supply to test them by themselves but just ordered one so I'll see if that cap is bad :(
@thewhitefalcon85397 жыл бұрын
I highly recommend against trying to stop a circular saw with one finger. Faulty motor or not.
@Jone367 жыл бұрын
A little unrelated perhaps but how about a video on MIC/Pyro cable¿ Termination, usage etc. Great videos btw, keep them coming
@PeterEdin7 жыл бұрын
Whats the typical construction material for these? I'm guessing it's a polypropylene capacitor.
@jwflame7 жыл бұрын
Yes, polypropylene with a metallised coating. Designed to fail safe (as in open circuit) and not set on fire or explode.
@PeterEdin7 жыл бұрын
Unless it's a Beko. Thanks John.
@tim627442 жыл бұрын
Good one John now I can test my capacitor s on my compressor she’s not starting
@iamdarkyoshi7 жыл бұрын
Take apart the blown one!
@farerse7 жыл бұрын
yes i want to see inside it!
@Jamal_Tyrone7 жыл бұрын
look at his pinned comment
@caemaridwn7 жыл бұрын
Cheers John nice explanation
@theworldaccordingtome64487 жыл бұрын
Hi, I don't understand why it's OK to over voltage your new cap. It looks like your new capacitor is rated for 500V at best, while your insulation tester was happy to apply at least 530V on it, perhaps even way higher for a split second. This seems to me like a good way to undermine the performance and longevity of your brand new cap. Otherwise, nice video.
@jwflame7 жыл бұрын
New capacitors would not normally be tested. Done in the video to show the difference between failed and new.
@simpliciocamirino22713 жыл бұрын
Thank you for that sharing sir.
@andrewchurchley57057 жыл бұрын
I repaired Murphy Richards hair dryers in the 60s. If not the flex, then it was always the capacitor.
@vmailtk57 жыл бұрын
Shouldn't you tell people to short out a capacitor via a resistor. I shorted out a capacitor with a pair of pliers, there was a massive bang, I went deaf for a few moments. And it burnt out 2 dents in the pliers
@chrismills89277 жыл бұрын
Nadim Awan2 a resistor is not the same as pliers the resistor will take the power and transfer it to heat and would burn out long be for the cap where as pliers are a dead short so yes I agree with you should use a resistor
@vmailtk57 жыл бұрын
Chris Mills bigclive said to use a resistor, what is the correct way to discharge a capacitor?
@chrismills89277 жыл бұрын
Nadim Awan2 sorry if what I said was miss leading I would go with bigclive and a resistor always the safer option
@gartmorn7 жыл бұрын
Chris Mills I would advise watching this video before discharging a mains voltage capacitor. I would not advise using a screwdriver unless you have no other means to hand as you may damage, a) yourself b) the capacitor and or c) the screwdriver! kzbin.info/www/bejne/poesh2xmataVr5I
@heavydiesel7 жыл бұрын
Just put a volt meter across the capacitor, it will slowly bleed the voltage across.
@paulmorrey7337 жыл бұрын
Thanks John Good information
@kokodin58957 жыл бұрын
why do i feel like this new capacitor was made in poland :] miflex such a nostalgic name
@glenwoofit7 жыл бұрын
Run capacitors and permanent capacitors are 450V when start capiciators are rated at 250V
@Mentorcase7 жыл бұрын
Anybody that has 1 of them fluke testers would already know how to use it, unless they they stole it, in which case they deserve to get a good booting from it!
@mrbadger99206 жыл бұрын
MGTOW REVELATIONS So you didn’t steal it yourself then. You are just part of the market for stolen goods? Not much difference in my opinion.
@davidprice28616 жыл бұрын
Good point. I agree.
@mitch196367 жыл бұрын
Thankyou John...
@dbayboyds4097 жыл бұрын
Great video thank you!
@atb10405 жыл бұрын
Very good video
@boonedockjourneyman79797 жыл бұрын
Failure to describe frequency dependance on all aspects of capacitors leads to idiotic things on KZbin. E.G. videos about “boosting” PWM “power” with capacitors to “get high torque motors to work.” Not your problem of course but it would be worth a video. You explain things well. Maybe you can get some sense into Arduino skills only types out there.
@peterbradley49167 жыл бұрын
cool. very simple too
@ron82205 жыл бұрын
why not use testing equipment the common person can afford. Your equipment is something most people have or will buy just to test a capicitor.
@SteS5 жыл бұрын
Multi meters aren't expensive. The one here is bit then again John makes a living from this.
@AhmedAli-jy1qm6 жыл бұрын
You are master electric
@deadfreightwest59566 жыл бұрын
"Those dreadful devices that go behind the toilet..." Alright, this Yank is baffled. What are you passing that needs chopping up? o.O
@jwflame6 жыл бұрын
www.saniflo.co.uk/
@LeverPhile6 жыл бұрын
Dreadful indeed.
@vincentonsoti26012 жыл бұрын
Powerful
@skrame017 жыл бұрын
air conditioner motors! central air has big ones.
@tridiproy78954 жыл бұрын
Hey you man madam madam hey you man madam madam madam fly in the sky
@hafizmushtaq29174 жыл бұрын
Urdu languages stater Ma repairing kashmiri hot and have