Carrier VFD problems?

  Рет қаралды 3,568

Everything HVACR

Everything HVACR

Күн бұрын

another carrier VFD failed, or is it? blower was not running on arrival, and I suspect the drive had a fault. I did not verify this and then found the fuses not blown. on reset, the drive started and ran. I decided in the end to bypass the drive to prevent another problem and wire in a contactor to control the motor.

Пікірлер: 36
@HVACGUY
@HVACGUY 11 ай бұрын
I’ve never quite seen a junction box for a capacitor. Gives new meaning to cap in a box
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
😆 I've seen these guys and have video on some sketchy shit they've done. That was above and beyond what I've seen previously 😆. Thanks Curtis
@ryanmcananey6245
@ryanmcananey6245 11 ай бұрын
If it’s a furnace, the fan won’t turn on with a call for heat… the gray wire on that VFD board will turn the fan on for heat and cool
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Almost missed it myself
@subcoolHVAC
@subcoolHVAC 11 ай бұрын
That unit probably runs 100% most of the time anyways in a restaurant. 👍 Good job pushing in the contactor too 🤣💪👊
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
😆 no doubt. Didn't give them an option, added the contactor, and charged them for it. I know this customer, if fixed, they ain't worried about it. Try to always be one step ahead. You know the deal. Thanks, Subcool!
@jochemsluis8834
@jochemsluis8834 11 ай бұрын
I like how they VFD the blower motor but have a fixed compressor to save power. Here in NZ we run variable speed compressors and blowers due to load and they don't use others brand of VFD's to do it. Temperzone make most of the package units here and are reverse cycle for heating until they get refrigerant logged in the outdoor coil.....🤣🤣🤣
@jrsmyth9761
@jrsmyth9761 11 ай бұрын
Carrier has a bulletin about installing the contactor and changing the fuses(fuses need to be replaced with correct size to match the motor). The unit's wiring schematic/diagram shows both the VFD wiring and the non-VFD blower wiring.
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Thanks JR
@ryanmcananey6245
@ryanmcananey6245 11 ай бұрын
Haha just saw the end of video… really good catch. A lot of people would have left that and not cared or realized
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Yeah, I honestly didn't think about it right away, but luckily caught it. Thanks Ryan
@stevencossaboon3237
@stevencossaboon3237 11 ай бұрын
Nice work Steve. Thank you for the knowledge.
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Thanks Steven.
@Eddy63
@Eddy63 11 ай бұрын
Good to hear from ya Steve-o ... Good vid as well ...Thx
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Thanks, Eddy! Every Thursday, bro, like clockwork, sometimes 😆
@jdaalmgren
@jdaalmgren 11 ай бұрын
0:47 is comedy gold
@joshstevens9826
@joshstevens9826 11 ай бұрын
Bumping contacters is common practice. As long as you are safe about it. Unless its a wye delta starter
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
😆. You gotta know what contactor you're bumping
@FrostHVAC
@FrostHVAC 11 ай бұрын
Florida knocks a lot of these VFDs out, its almost like you should never quote them anymore, they always get declined. Ive replaced one before though, not hard, just had to have fun with ABB lol
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
If they were in a different location, they might last longer. No one replaces here either unless their under warranty.
@FrostHVAC
@FrostHVAC 11 ай бұрын
@@EverythingHVACR I never understood why they put it in the blower section, I get to keep it cool but man it does get hella moist in there...
@alessichris07
@alessichris07 11 ай бұрын
👍👍👍
@MariosACandRefrigeration
@MariosACandRefrigeration 11 ай бұрын
Nailed it,great fix,thanks for sharing.
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Thanks Mario
@MarcosHVAC
@MarcosHVAC 11 ай бұрын
I’m stealing that capacitor idea 😂
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
😆 it's all you, bro 🤣
@ccthepope
@ccthepope 11 ай бұрын
You da man!
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
I'm something 😆. Thanks, r aeronca!
@stephenbullock-yn3vh
@stephenbullock-yn3vh 11 ай бұрын
Excellent fix 👍
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Thanks Stephen.
@courtrutherford8913
@courtrutherford8913 11 ай бұрын
In my experience it's 2 weeks to a month later that drive will trip again.
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Ohh, no doubt that's why I went ahead and bypassed it, not worth a call back.
@eastcoast186
@eastcoast186 11 ай бұрын
Great information video thanks
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Thanks East Coast
@helmsajr
@helmsajr 11 ай бұрын
Great job Steve
@EverythingHVACR
@EverythingHVACR 11 ай бұрын
Thanks Jr
MULTIPLE CARRIER VFD FAILURES
12:42
HVACR VIDEOS
Рет қаралды 46 М.
HOW TO TEST IF A VFD ( Variable Frequency Drive ) IS BAD WITH A MULTIMETER
11:57
Watermelon magic box! #shorts by Leisi Crazy
00:20
Leisi Crazy
Рет қаралды 23 МЛН
LIFEHACK😳 Rate our backpacks 1-10 😜🔥🎒
00:13
Diana Belitskay
Рет қаралды 3,9 МЛН
ABB VFD Setup for Staged Air Volume RTUs
9:58
Tec Tube
Рет қаралды 3,8 М.
Carrier Economizer Troubleshooting
17:18
Arista Air Conditioning Training Videos
Рет қаралды 2,3 М.
How to bypass the VFD?
10:52
Taddy Digest
Рет қаралды 27 М.
How To: Troubleshoot VFDs
11:30
Radwell International
Рет қаралды 35 М.
HVAC VFD Operations & Troubleshooting
1:43:26
HVACTIME
Рет қаралды 19 М.
How To Remove a Rusted Blower Wheel Tech Tips
9:10
Anti DIY HVAC
Рет қаралды 60 М.
Unit is not Cooling, No AC Service Call
12:37
HughesMan HVAC
Рет қаралды 9 М.
Watermelon magic box! #shorts by Leisi Crazy
00:20
Leisi Crazy
Рет қаралды 23 МЛН