Case 133: Manual of PCI - SVG perforation

  Рет қаралды 4,585

Manos Brilakis

Manos Brilakis

Күн бұрын

Пікірлер: 13
@cdratik
@cdratik 3 жыл бұрын
IS that a small air embolism inthe first shot of the filterwire?
@tom11298
@tom11298 3 жыл бұрын
Excellent educative points, undersized stents for SVG is a great point to keep in mind.
@ahmedmed4811
@ahmedmed4811 3 жыл бұрын
Was there air embolization in the cine after protection device insetion ?
@dmx-spark
@dmx-spark 13 күн бұрын
i too feel that unless the perf causes a rapid tamponade and hemodynamic collapse its better to resort to covered stent directly,rather than spend time doing a balloon inflation to stop perf
@denizaktürk-j7n
@denizaktürk-j7n 3 жыл бұрын
Thank you for this brief for management of SVG perforarion. This was very educative and efficient for me.
@ramidudin1
@ramidudin1 3 жыл бұрын
Thank you for share this case, I think if IVUS done post stent inflammation, it could show stent over inflation more than 4.00 mm?.
@svijaykumarreddy1242
@svijaykumarreddy1242 3 жыл бұрын
Very nice handling of SVG perforation
@mohdiqbaldar881
@mohdiqbaldar881 2 жыл бұрын
thanks a lot. all of ur cases are great learning. few points in this case. the first angio cine showed air embolism, air bubble going down the graft and OM. there is a wire like thing just parallel to OM (6:54), what is it?
@shangz0216
@shangz0216 3 жыл бұрын
Thanks for the educative case sharing.
@MohamedAhmed-wx9wk
@MohamedAhmed-wx9wk 3 жыл бұрын
Great management. In general, i really don’t see a great advantage of this “ping pong “ technique. It is very short time to exchange a balloon for a covered stent and unlikely to cause significant hemodynamic instability. Also, why no one inflate a balloon on a buddy wire then deflate , retract the balloon to a single guide at the time of stent delivery?
@LTzEz03z
@LTzEz03z 3 жыл бұрын
@3:40 The What? Technique?
@zaidhakim
@zaidhakim 3 жыл бұрын
Thanks for this case. Very informative. Do you think this was caused by oversizing the stent? My understanding is we normally go 0.5 mm less than what the IVUS tells us i.e. if 4 mm then u pick a 3.5 mm stent.
@manosbrilakis
@manosbrilakis 3 жыл бұрын
Probably - choosing stent size depends on what you are measuring: if you are measuring distal lumen size you choose a stent that is 0.25 mm larger - if you are measuring "media to media" you downsize by 0.25 mm.
Case 134: Manual of PCI - Stent loss
7:59
Manos Brilakis
Рет қаралды 3,5 М.
Case 93: Manual of PCI - Hairpin Trap
10:17
Manos Brilakis
Рет қаралды 9 М.
Хаги Ваги говорит разными голосами
0:22
Фани Хани
Рет қаралды 2,2 МЛН
GIANT Gummy Worm #shorts
0:42
Mr DegrEE
Рет қаралды 152 МЛН
Case 206: Manual of CTO PCI - Giant SVG aneurysm
14:02
Manos Brilakis
Рет қаралды 2,2 М.
Massive Coronary Perforation, Coils, and Pericardiogram
16:48
6 in the A
Рет қаралды 9 М.
Case 57: PCI Manual - Native coronary PCI via SVG
13:33
Manos Brilakis
Рет қаралды 4,3 М.
Case 142: PCI Manual - Bifurcation PCI: three in one
9:06
Manos Brilakis
Рет қаралды 4,3 М.
Module 10, Bypass Graft Angiography and PCI via TRA Access
14:15
Coronary circulation of the heart
15:29
The Noted Anatomist
Рет қаралды 1,6 МЛН
Case 140: PCI Manual - Wait until the end...
8:51
Manos Brilakis
Рет қаралды 3,6 М.
Case 84: PCI Manual - Double stent thrombosis
7:39
Manos Brilakis
Рет қаралды 4,7 М.