Cat 6A amazing dressing and termination

  Рет қаралды 37,314

Eddie R Cool

Eddie R Cool

Күн бұрын

Cat 6A dressed and terminated by design.

Пікірлер: 24
@bobkriegisch2731
@bobkriegisch2731 4 жыл бұрын
Now that’s a piece of art
@perpetualjon
@perpetualjon 8 жыл бұрын
You'll have to do a time-lapse video one of these days.
@rrrohan2288
@rrrohan2288 6 жыл бұрын
i feel bad for old school telephone techs. no way they could cable pairs as neat as this
@djrequest333
@djrequest333 5 жыл бұрын
rrrohan2288 my dad can. But he’s been doing it for 20 years
@andybrookins185
@andybrookins185 6 жыл бұрын
I think I’m in love 😍
@Pl4sm0
@Pl4sm0 5 жыл бұрын
Cablegasm :D
@alexis_dc2
@alexis_dc2 5 ай бұрын
All this beautiful work for IT guys to come in and plug 10ft patch cords all over the place smh
@itslexiandgrace2259
@itslexiandgrace2259 5 жыл бұрын
Did you use a cable comb?
@noliyoungtv
@noliyoungtv 2 жыл бұрын
Hi sir,can you teach me how to setup the 48 cable comb?I'm interested to know...couze I'm a installer here in the Philippines..
@NicholasGomber
@NicholasGomber 18 күн бұрын
clean dress work. red velcro represents Plenum, so don't show the boss. i personally would have dressed a little service loop before exiting the wire manager. And would have used the support bars that came with the patch panel.....overall 7/10.
@sureshkumarssb
@sureshkumarssb 28 күн бұрын
I know this work, if needed please tell me sir
@anthonycastro6894
@anthonycastro6894 8 жыл бұрын
how would you go about replacing a bad cable or port on the patch panel? just run a new line and leave the bad one in?
@djrequest333
@djrequest333 5 жыл бұрын
anthony castro typically yes. Cut the cable inside the bundle at a point where it won’t be noticed then try to dress the add about where the old cable was.
@lia....
@lia.... 6 жыл бұрын
怎么做到的想学习一下
@lance8080
@lance8080 4 жыл бұрын
Way to anal.
@morgan5941
@morgan5941 7 жыл бұрын
I'm a little unimpressed by this. You drop the ball at the termination. There's a lot of slack variation, none of it is parallel. Your use of Velcro reveals you value functionality over quality. You didn't put any effort into training the bundles into shape, they all droop below the termination. The work as a whole is good enough, but it's several steps below amazing.
@carlitosenvivo3928
@carlitosenvivo3928 6 жыл бұрын
Morgan S you very well represent people's envy at the maximus.
@itslexiandgrace2259
@itslexiandgrace2259 5 жыл бұрын
Morgan go fuck yourself
@eddycool13
@eddycool13 5 жыл бұрын
Morgan s. There's reasons for the way the cables are terminated that way. One of them is because these cables are Cat6a, so the cables need a longer ratio bend close to the panel. I made them longer also because we were gonna install POE switches below every patch panel , the main reason for that is because I would be easier for us to fix, add or service the cables, plus we wanted to mount support bars in the back but the client didn't see the need of them.
@oskermedina
@oskermedina 18 күн бұрын
​@eddycool13 how's ruben😅
@johnmcgourney3277
@johnmcgourney3277 Жыл бұрын
How long does that take
@stenergut9661
@stenergut9661 4 жыл бұрын
But why? What is this for ?
@gailanthony2309
@gailanthony2309 5 жыл бұрын
That's so purtyyyy.
Bundling and dressing Cat5, Cat5e, Cat6 with a cable comb
3:26
Discount Low Voltage
Рет қаралды 97 М.
How do Cats Eat Watermelon? 🍉
00:21
One More
Рет қаралды 9 МЛН
Остановили аттракцион из-за дочки!
00:42
Victoria Portfolio
Рет қаралды 3,7 МЛН
Cat 6 patch cords showing the front for the first time
2:23
Eddie R Cool
Рет қаралды 28 М.
Instalación de DataCenter
8:02
Josue Medina
Рет қаралды 1,4 МЛН
Making another pickproof lock (but better)
15:14
Works By Design
Рет қаралды 4,2 МЛН
Data room clean up/rebuild
4:06
120estelle
Рет қаралды 264 М.
Z MAX F UTP Termination
6:03
Siemon Company
Рет қаралды 2,2 М.
Data Center Rebuild
19:40
System MTU One
Рет қаралды 2,1 МЛН
TrendNet Shielded Patch Panel
5:21
Mike Faucher
Рет қаралды 9 М.
Technimove - Environment Re-Cabling (Before & After)
2:32
Technimove
Рет қаралды 674 М.
Cat 6 amazing dressing and termination
2:04
Eddie R Cool
Рет қаралды 2,4 МЛН