Cavitation in a water pump

  Рет қаралды 154,669

BTCInstrumentation

BTCInstrumentation

Күн бұрын

Пікірлер: 38
@laramie5239
@laramie5239 9 ай бұрын
I can't believe this video has been around for over a decade and I've never seen it. This is the most informative demonstration I've ever seen for cavitation.
@Ayoub-rg6jo
@Ayoub-rg6jo 2 ай бұрын
Thank you finally I understood the cavitation. This is gold.
@prof.charlesassuncao
@prof.charlesassuncao 9 ай бұрын
The best demonstration ever. I always show it to my students in Brazil. Congrats!
@DGman4
@DGman4 9 жыл бұрын
Excellent demonstration, thank you. I feel bad for that pump.
@Pat.Szafran
@Pat.Szafran 2 жыл бұрын
Watching this and listening to you speaking so calmly was a stressful experience. Thanks.
@AppliedScience
@AppliedScience 12 жыл бұрын
It's interesting to see this with a clear pipe system.
@adamszongo4769
@adamszongo4769 6 жыл бұрын
moi je suis superviseur de dewatering dans une mine alors jaimerais faire une formation de renforcement de capacite
@BTCInstrumentation
@BTCInstrumentation 11 жыл бұрын
Increase the static pressure so that the minimum pressure never falls below the liquid's vapor point; decrease the temperature to depress the vapor's flash pressure.
@aymanmalek1294
@aymanmalek1294 4 жыл бұрын
"And that's a happy pump" xD
@Brunomills
@Brunomills 9 жыл бұрын
Great explanation and demonstration!
@dominikjaremek3120
@dominikjaremek3120 10 жыл бұрын
Great demonstration of cavitation. Thanks for postin this video.
@CapedChronicles
@CapedChronicles Жыл бұрын
Thanks for the explanation! Very interesting!
@ashishkumartiwari7031
@ashishkumartiwari7031 7 ай бұрын
Excellent 👍
@Defundemorats
@Defundemorats 5 жыл бұрын
Very interesting and very well explained thank you
@benmccluney8922
@benmccluney8922 2 жыл бұрын
Thank you!
@adoinstru
@adoinstru 11 жыл бұрын
thanks for the video. Well, how can we improve or get rid of cavitation( in orifice or venturi)?
@valeriybeleychuk823
@valeriybeleychuk823 4 ай бұрын
It would be very informative if it’s possible to make demonstration when water level goes below water pump level and how to provide suction when water level is below pump
@notabused
@notabused 9 жыл бұрын
Well explained. Thanks.
@Ragavenutb
@Ragavenutb 2 ай бұрын
Hi, was wondering if discharge valve is slightly shut and the pump is running will that too cause cavitation to build up ?
@FishnSkip
@FishnSkip 9 ай бұрын
Is it possible for cavitation on an outboard engine to cause a noise like this at 2-3 mph ? But smooth any other speed. Or does it need to be in a closed system for that noise
@arunprasanth1726
@arunprasanth1726 8 жыл бұрын
Excellent !! I would like to buy this whole setup for Research purpose... I am from singapore.... How do i buy this setup??
@djoudjou1214
@djoudjou1214 Жыл бұрын
I liked your upscale page posts
@mujahidurrehman7504
@mujahidurrehman7504 8 жыл бұрын
Excellent Demo....!
@mashed-out
@mashed-out 7 ай бұрын
Be careful, that cavitation you see just after the suction valve is caused by the pressure drop through the valve not the pump...sending them to the pump.
@pogiako5586
@pogiako5586 10 ай бұрын
is there a formula to determine the reduced pressure from the inlet due to closing of the inlet valve? or do you know any paper explaining the pressure drop due to the closed valve?
@atmikes1
@atmikes1 6 жыл бұрын
Excellent, thanks!
@engsherif4657
@engsherif4657 5 ай бұрын
Great thanks for explean expermantal the cavation
@arunprasanth1726
@arunprasanth1726 8 жыл бұрын
What is the pump model and valve type used in suction side?
@qas168888
@qas168888 7 жыл бұрын
tube probably feels cold too?
@pedrusi
@pedrusi 12 жыл бұрын
why the manometer has pressure when there isnt flow?
@SDTHearMore
@SDTHearMore 11 жыл бұрын
You can ealisy hear and find this kind of problem on a pomp thanks to the ultrasounds ! Check our youtube channel !
@AlexMassias
@AlexMassias 10 жыл бұрын
enfin, on voit ce qui se passe vraiment
@georgemangatt4705
@georgemangatt4705 8 жыл бұрын
USER SDTUltrasound to measure the cavity . a very advanced and easy tool//
@freelectron2029
@freelectron2029 5 жыл бұрын
you should be careful doing that. Due to the Leclaire effect you can be producing gamma waves. you should do the same experiment but with a Gigacounter running nearby.
@raulitoo88yt93
@raulitoo88yt93 2 жыл бұрын
Mucho betis
@resystanc3
@resystanc3 10 жыл бұрын
BE AWARE OF THE RADIATION!!! MEASURE IT WITH DOSIMETER!
@BTCInstrumentation
@BTCInstrumentation 8 жыл бұрын
Radiation? From what??
@resystanc3
@resystanc3 8 жыл бұрын
From annihilation. Dosimeter is your friend.
Cavitation Demo
5:25
Fisher Valves & Instruments
Рет қаралды 321 М.
IL'HAN - Qalqam | Official Music Video
03:17
Ilhan Ihsanov
Рет қаралды 700 М.
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 958 М.
Cavitation Mitigation Solutions Part One: Cavitation Overview
8:14
Fisher Valves & Instruments
Рет қаралды 45 М.
Cavitation - Easily explained!
10:12
IET Institute for Energy Technology
Рет қаралды 1,1 МЛН
What causes pumps to cavitate? And why is my pump so LOUD?
3:19
Viking Pump®
Рет қаралды 8 М.
Positive Displacement Pump Types
9:24
Laney Machine Tech
Рет қаралды 686 М.
pump cavitation and net positive suction head
6:45
technoworks
Рет қаралды 135 М.
TFD Kavitation
9:50
IET Institute for Energy Technology
Рет қаралды 86 М.
What is Cavitation? (with AvE)
8:25
Practical Engineering
Рет қаралды 1,5 МЛН
Science Fix | What is Cavitation?
2:26
Element 18
Рет қаралды 32 М.
IL'HAN - Qalqam | Official Music Video
03:17
Ilhan Ihsanov
Рет қаралды 700 М.