I'm very happy with the Synesso Hybrid two group. It is one of the most powerful machine known and best of all is the service videos provided! No other companies can match that combination.
@SynessoInc8 жыл бұрын
+paul I Thanks Paul! If there is ever any support you need that you can't find here, just call us here at the factory!
@icewizz882 жыл бұрын
Thank you for this! I have a La San Marco 85E Sprint that seems to only dispense from the heads at 120. No steam and not hot water from the dispenser. I'm guessing it is the heating elements so time to test!
@albertschweitzerthe3rd9082 жыл бұрын
I noticed your heating element checking video here. is it proprietary only to your type of product? I have an Empura brand four tray heating table. each element is simple real simple to like a oven type of an element but little smaller obviously. I was looking at your own readings that you were saying. I tried to apply them to the same thing even though they're just a single element it's a 240 for tray table. I did a test for Ohm's continuity, I got tone and I got about 65 ohms right on my meter. I tested with another meter just to check got a roughly about the same thing. I disconnected the wires of course going to the element. but could not get the damn thing to come out of the tray it had a hole down little piece of metal that went through and damn things I don't know what it's rested on or were they glued it on or whatever you know a little screw plate that holds down over where the elements go through the bottom of the table. so I tested them with that by pulling the two wires off of the elements and then connecting right to the end leads of the element and got 65 ohm and continuity tone. I am assuming that is a true read, though I am interested from another service person to see if my methodology was correct and that the element must be good because I'm not getting zero on the meter and I am getting tone even though it's a 65 ohm reading
@seanbeharry93198 ай бұрын
Hi there. I have a 240 3000 watts water boiler 13.5amps that over heats the 3pin plug. I will be testing for current draw today. any tips.
@alamgul83412 жыл бұрын
I have 3 elements of 230 volts single phase. But I have power supply 380 volts 3 phase how utilities the same to get connected.please send the reply.
@rivusarkar86294 жыл бұрын
Sir please tell me what is the meter you used and where it purchased
@lydiadulla53464 жыл бұрын
cisa 200 steam autoclave not heated up what would most probable cause and its remedy
@RadhyRadhy963 жыл бұрын
we are manufacturing heater element in any size in any weight according to requirement
@thefunnyseeker4373 жыл бұрын
Why the elements keep failing on meg testing ? Is it because of the high humidity