HEATING ELEMENTS EXPLAINED

  Рет қаралды 74,885

Barley and Hops Brewing

Barley and Hops Brewing

Күн бұрын

This channel is designed to offer insight and background on the science, art and practice of making alcohol based products at home. neutral spirit distilling how to make gin barley bourbon barlerandhops

Пікірлер: 84
@Turts_McGurts
@Turts_McGurts 3 жыл бұрын
keep it up george! youre killing it ! thank you for all these videos! ive learned almost EVERYTHING i know from you!
@jorgemercado7505
@jorgemercado7505 2 жыл бұрын
MIND BLOWN! Thank you for helping me understand the concept.
@dixonjames4177
@dixonjames4177 3 жыл бұрын
Thanks for this George. Happy Distilling!!
@HodgyE5
@HodgyE5 3 жыл бұрын
Thank you for the video and thank you for keeping the community safe.
@warrencourt7938
@warrencourt7938 3 жыл бұрын
Hi George, I'm now 3 months into my new hobby. Started with the air still, now with the T500 with reflux column and just got the alembic dome today to expand my options. Your video's have been a great in aiding my understanding of the craft. I really do think I will end up progressing further in the future with one of the fantastic 8 gallon stills available from the USA. I had considered the outback from mile high, but the options for heating an PID options worried me with the 240v here in blighty. Thank you buddy, your enthusiasm is infectious.
@darencuthbert11
@darencuthbert11 3 жыл бұрын
Hi Warren, i'm in the same boat as you, about to invest in an outback, did you resolve your concerns about the PID and our UK electrical system?
@KateBlackford
@KateBlackford 3 жыл бұрын
Awesome thanks for the info! Clarified a bit about the relationship about 240v and neutral. Thank you.
@barishp
@barishp 3 жыл бұрын
very good video I was searching to find smt helpful to know how to change esspresso machine heater element, I got so much deep information before that. good video, a lot information :) thx
@zupermx
@zupermx 3 жыл бұрын
Great information, thank you!
@martybernier9313
@martybernier9313 3 жыл бұрын
A word of caution. Don't screw the element too tight. The gaskets tend to squish out of the contact area and leak. Love the videos George. Can't tell you the number of times I've gone back to one just to solidify the knowledge of the process.
@guidedbygreen1480
@guidedbygreen1480 9 ай бұрын
Good advice, I made mine very snug. Hopefully not too tight!
@digitaria
@digitaria 2 жыл бұрын
In the UK we always use the Neutral and depending on the classification of the equipment we also use the earth/ground.
@johntadlock693
@johntadlock693 3 жыл бұрын
Great info! Thanks George. Logger John.
@kobiroar4221
@kobiroar4221 Ай бұрын
Great video mate thanks
@jbwagonmaker2820
@jbwagonmaker2820 3 жыл бұрын
Great video, as usual, I shared it on in my group MOONSHINE LIFE GROUP, With 28,000 members
@BarleyandHopsBrewing
@BarleyandHopsBrewing 3 жыл бұрын
Thanks for sharing!! Hope all get some value from it. George
@showme....6043
@showme....6043 2 жыл бұрын
Hello George. Hoping all is well. I have been a fan of yours for a while and love your videos. I have a quick question for you. I have a 15 gallon keg still and a 1650 watt element. It's also a drop down element instead of coming through the side. What are your thoughts on this. Thank you in advance.
@speedbuggie
@speedbuggie 3 жыл бұрын
You are the Best!
@timdekleijn4414
@timdekleijn4414 2 жыл бұрын
Thanks alot for this detailed information! I've learned a few things for which i'm gratefull. Sub +1 and i'll definitely watch more of your content in the future. Take care and best wishes for 2022!
@ryesorenson4393
@ryesorenson4393 3 жыл бұрын
I really like the idea behind the PID controller the only problem is I don't have one or the heating elements and adapter stuff for installing the elements.
@BeADad2447
@BeADad2447 2 ай бұрын
I feel like I went to the school I could never afford as a kid! Thank you sir!
@crazydad4058
@crazydad4058 Жыл бұрын
Thank You Sir!
@W4EMB
@W4EMB 3 жыл бұрын
George, can't find the 1" weld less bulk head. Followed your link, it only takes me to a 1/2 or 3/4 ... Any help? Thanks George, you have been very helpful! Keep 'em coming.
@chasebishop4346
@chasebishop4346 3 жыл бұрын
Here you go Ed. minibrew.com/collections/best-sellers/products/1-ez-seal-weld-less-bulkhead Its a bit more expensive than when he made that video, but its the same product. Happy Distilling!
@azizihors3598
@azizihors3598 2 жыл бұрын
Thank you so much
@CuriousEarthMan
@CuriousEarthMan 2 жыл бұрын
THAT was interesting.....thank you! Split phase...I never thunked it that way! Your PID videos should be very nutritious too I would think! lol
@sparky6086
@sparky6086 29 күн бұрын
Actually, Europeans found that 40hz was the most efficient, but 40hz caused a very annoying flicker from light bulbs, so they went up to 50hz which was fast enough, where the flicker wasn't perceptible. There's a rational behind 60hz & other currents too, but I can't remember them off the top of my head.
@mamatuja
@mamatuja 2 жыл бұрын
If all my teachers when I was young we're teaching the way you do I would be a whole lot smarter today.😁
@horaciomejia7379
@horaciomejia7379 3 жыл бұрын
hello sir I just found your channel I have a question I`m trying to make a revolving food dryer to dry chili peppers are those heating elements appropriate for a dryer with a fan or some kind of blower. I have a food dryer that I bought from amazon but I think the process would be more effective and more product would fit if it were in a revolving enclosure kinda like a clothes dryer but for chili peppers.
@ailkenllib
@ailkenllib 3 жыл бұрын
Great info George. I'm not totally clear on the threaded elements though. Are they typically ok to be just threaded into a stainless keg, or do I really need to try to get a nut on the inside? Haven't got time to get a TC fitting welded on and was hoping to just drill and tap a hill for now, but not if it's not the best choice.
@ailkenllib
@ailkenllib 3 жыл бұрын
Thanks for the email George about not using a nut, but that it wasn't ideal. I found that a 1" female copper adapter has the correct thread for a heater element. I figure I can cut the nut portion of the adapter off and use it as a nut on the inside of a kettle to hold the element tight.
@yelle84
@yelle84 2 жыл бұрын
Can you use a thermostat on these heating elements? If so , do you have a specific model you'd recommend?
@markellis7961
@markellis7961 3 жыл бұрын
What about the wattage in regards to column size and flow rate of the distillate. I'm just using a T500 and a 2200W boiler, which works fine, but on one of your other videos "refluxing", you had another reflux still that you refered to as the sexed up beast, i'd love to run something like that, what currently take me 3-4 hours, i could do in 1hr on that thing, but would i need a stronger element to do it. I currently have 10 amps, I could easily get a 15 amp (240v) 3600W wired up easy enough, but any more then that I'd have to get 3 phase installed which is probably more trouble then it is worth. Running 5-8 gallon batches Thanks
@paulputter9711
@paulputter9711 3 жыл бұрын
Hi George, a quick question. If the stove on your diagram are fitted with 120v elements, will the neutral wire then be necessary.
@thomasa5619
@thomasa5619 3 жыл бұрын
It’s nitpicky but as an Australian electrician... You can also have 2 phase (well, it’s 2 phases out of 3 phase) but 120V@120° is 207 so it’s generally close enough to 240
@virgilmccabe2828
@virgilmccabe2828 3 жыл бұрын
You can also have a 3 phase delta or a Y- open delta with a high leg. Voltage may range from 120 to 277
@vijayakrishnannair
@vijayakrishnannair 7 ай бұрын
Nice 👍
@hycron1234
@hycron1234 2 жыл бұрын
17:06 - I guess by creating its own neutral, it only works because they are out of phase in the waveform, meaning they won't interfere with each other, and each 120v line uses the other 120v line as its neutral wire or return path to complete the circuit on a 240v appliance. Kinda clever because then you don't end up running an additional neutral wire just to get 240v to appliances that need it.
@danielgodfrey4415
@danielgodfrey4415 11 ай бұрын
I bought a 1350w element. I only have it hooked up to my wall outlet. For 12 gallons it keeps it around 90C And its soo much faster than my commercial 120v induction cooker.
@SurajPatil-nz8rm
@SurajPatil-nz8rm 2 жыл бұрын
Can you guide us to understand difference between DC and AC Heating elements.. can i use AC element for DC heating purpose ?
@cheareenmjones6105
@cheareenmjones6105 2 жыл бұрын
I’m sure a little tiny fusion ring 💍 will heat elements in the near future and everyone will have a pocket size element synthesizer to travel places with.
@anthonywellington3186
@anthonywellington3186 2 жыл бұрын
To whom it may concern I have a Bain Marie 6 pan food warmer the heating element burned out which is a110 volt 1.5kw which am having a hard time finding a replacement I see on that a120 volt would it hurt if I use it in my 110 volt unit
@adhdengineer
@adhdengineer Ай бұрын
uk doesnt use split phase for domestic properties, you could probably get it fitted if you had to, but it's definitely not standard. 230v single phase, 100amp on newer properties, sometimes as low as 60 on older. And then there are ring mains ;)
@stuartmackay9270
@stuartmackay9270 3 жыл бұрын
Please note in the UK, we use single and three phase systems, similar but different...
@juusolaukkanen710
@juusolaukkanen710 3 жыл бұрын
And all on EU
@94iaco
@94iaco 3 жыл бұрын
Hi, i have a problem that maybe you can help me with, i have modified a pizza elettric oven that has 2 heating element, one under the coking plate and one above it (both of them are 600watt), i have removed the bottom one and placed on top together with the other one, for a total of 1200watt above the plate, i reach 430 degrees celsius on the coking plate for coking pizza, but the problem is that after the coking i have found metal particles on the coking plate (a lot of them like a powder) and i have used a magnet for picking up this particles, now the oven is made from stainless steel aisi 300 series and its not magnetic and it has no visible sings of corrosion, i think that the metal particles come from the heating elements (the magnet do not stick to them too so probably also aisi 300 series), and also this wasnt happening before i placed the bottom heating element above, together with the other one, do you know what is going on? the heating element are in apparently good shape i dont see any visible signs of corrosion or rust on them, one thing to mention is that the heating elements touch eachother (for a reason of tight space available in the oven) so maybe when they heat up and expand and then cool down and reverse there is friction between them, or maybe is beacuse they heat up to much (the glowing color bytheway is red not orange or yellow). Do you know what those metal particles can be? Thanks
@REEL_BADMANN
@REEL_BADMANN 2 жыл бұрын
So can I connect a 2000watt 120v element to a 12/3 cord and 15amp 125v plug
@h0wud0in1
@h0wud0in1 Жыл бұрын
what is the efficiency of this heater, what is it made of?
@macmckulis7440
@macmckulis7440 2 жыл бұрын
So I can just wire the element without and other equipment, and plug it in?
@shawncowney
@shawncowney Жыл бұрын
I would like to contact you privately if possible. I am working on my own design of an appliance and was trying to better understand elements. as I would need to do a dry run with teflon tape and in a custom shape which may or may not become commercial one day. In SOUTH AFRICA we firstly dont have electricity. and when we do its for a 1/4 of a day
@juusolaukkanen710
@juusolaukkanen710 3 жыл бұрын
Is there any difference on ac and dc elements?
@gowitladram4843
@gowitladram4843 20 күн бұрын
What about different type like IECEx rated elements
@jackf498
@jackf498 3 жыл бұрын
is there a formula to determine a heating element wattage to keep any givin sized curing oven(powder coating) at a specific temperature? So for example lets say an oven is 27cu ft that needs to maintain a 400*F temperature.
@virgilmccabe2828
@virgilmccabe2828 3 жыл бұрын
These heating elements can only be used while immersed in liquid. Otherwise it will burn out
@virgilmccabe2828
@virgilmccabe2828 3 жыл бұрын
There are some elements designed for dry use but the ones George is displaying are designed for a water heater
@adiefender
@adiefender 3 жыл бұрын
the other point, is that Neutral and Ground are bonded together in the breaker panel.
@BarleyandHopsBrewing
@BarleyandHopsBrewing 3 жыл бұрын
Yes, but only at the first point of entrance to the structure. Any sub-panel has a separate ground.
@jonathandoeghtery3199
@jonathandoeghtery3199 2 жыл бұрын
my distiller is turning off early. I have replaced both sensors. Still turns off. Is the heating element overheating? Why and what is up? Looks like no way to replace my element, its welded? Anyone comment ty
@user-cy1sh8mp2k
@user-cy1sh8mp2k 7 ай бұрын
good!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
@user-cy1sh8mp2k
@user-cy1sh8mp2k 7 ай бұрын
what?
@keeptrying7640
@keeptrying7640 Жыл бұрын
Hay brother I got a question can you rin a 12v element on 220v
@danielgodfrey4415
@danielgodfrey4415 11 ай бұрын
He said you could run 120v on a 220v but it'll reduce your wattage.
@Stewbphoto
@Stewbphoto 3 жыл бұрын
I have gotten a few heating elements from the hardware store but i always have a problem with them rusting.. any way to avoid this?
@cowcountry7007
@cowcountry7007 3 жыл бұрын
Stainless
@thomasa5619
@thomasa5619 3 жыл бұрын
Generally a hot water system will have cathodic (or is it an anode?) protection for that Maybe just quickly heat it up while the still is empty to dry it. Don’t heat it cherry red, just flash the liquid off.
@markellis7961
@markellis7961 3 жыл бұрын
What about a false bottom, so the heating element doesn't come into contact with the water, i use the grainfather which has that, works well.
@shawncowney
@shawncowney Жыл бұрын
IF YOU WERE MY TEACHER YEARS AGO I WOULD OF PASSED 🤣🤣🤣
@mightyofall
@mightyofall Жыл бұрын
He’s goood
@cowpiecowboy7599
@cowpiecowboy7599 3 жыл бұрын
Mr George sometimes I think you give us too much knowledge. My experience adds up to.Can you ? Well sure but should you? After three years I’m going back to slow and easy..
@Lo7q7le7guste7mrtf
@Lo7q7le7guste7mrtf Жыл бұрын
To my understanding it,'s 230v in EU and 50hz
@johnsteamer828
@johnsteamer828 Жыл бұрын
We use 240v 50hz in Australia
@digitaria
@digitaria 2 жыл бұрын
Oven elements aren't submerged
@user-cy1sh8mp2k
@user-cy1sh8mp2k 7 ай бұрын
bru!
@northernadventurer160
@northernadventurer160 2 жыл бұрын
Just came here to say UK is not 440v
@AceGod7
@AceGod7 3 жыл бұрын
lol
@randolphbehm877
@randolphbehm877 3 жыл бұрын
Too many Biden approved adds......🤣 a lot of great info here though... Thanks!
@BarleyandHopsBrewing
@BarleyandHopsBrewing 3 жыл бұрын
Sorry I do not control ads.
@brianzar1943
@brianzar1943 2 жыл бұрын
make the videos shorter man
@ducsieuma8884
@ducsieuma8884 3 жыл бұрын
with respect to his career and knowledge, his teaching is terrible. Look at the drawing of 240, the 120 wires are connecting to the same point. That is not good teaching
@bobnewhart4318
@bobnewhart4318 3 жыл бұрын
Go elsewhere then
@levigodro9827
@levigodro9827 2 жыл бұрын
He’s a great teacher. The student is the issue
@iancashwell9463
@iancashwell9463 3 жыл бұрын
Have you heard of anyone using an outside heating element like on a table top autoclave? Google pn HEA010-0018
@BarleyandHopsBrewing
@BarleyandHopsBrewing 3 жыл бұрын
Have not heard of that. Not sure how that would work.
WHICH  ELEMENT DO I NEED FOR MY STILL
11:04
Barley and Hops Brewing
Рет қаралды 31 М.
Ultimate DIY Electric Kiln Guide - The Heating Elements (part 2)
8:20
Её Старший Брат Настоящий Джентельмен ❤️
00:18
Глеб Рандалайнен
Рет қаралды 8 МЛН
1 класс vs 11 класс  (игрушка)
00:30
БЕРТ
Рет қаралды 3,6 МЛН
Final muy inesperado 🥹
00:48
Juan De Dios Pantoja
Рет қаралды 14 МЛН
A simple water heater is more clever than it seems
22:52
Technology Connections
Рет қаралды 1,9 МЛН
Does a Water Heater Really Need to be Drained and Flushed?
12:16
Word of Advice TV
Рет қаралды 1,1 МЛН
I Made A Historic 1700's Absinth
28:38
Still It
Рет қаралды 1 МЛН
Incredible Technique of Making High Quality Electric Rod Heater
9:03
How To Tell If Your Water Heater Element Is Bad
13:46
TheDurbinCompound
Рет қаралды 841 М.
Revolutionary Paint: How to Make Surfaces Stay Cool in the Sun
49:39
Tech Ingredients
Рет қаралды 737 М.