Chimney design by Staad Pro Software

  Рет қаралды 11,298

Civil Engineering by Shravan

Civil Engineering by Shravan

Күн бұрын

Пікірлер: 16
@aashishp007
@aashishp007 4 жыл бұрын
It was good, but incomplete For any one making videos on Structural Analysis &Design plz provide code references & Load combinations during the video. Also apart from super structure give inputs about Foundation as well to make it complete.
@adithyakalyan1382
@adithyakalyan1382 5 жыл бұрын
Thank u so much
@kasperlee5974
@kasperlee5974 3 жыл бұрын
could you please demonstrate how wind load can be applied on the stack?
@jayashreebhosekar9714
@jayashreebhosekar9714 2 жыл бұрын
Hi Shravan! I have attempted to design the chimney with the same specifications & parameters and on analysis I have been informed that there are 400 errors (=No of elements) and error message is The design moment exceeds the limiting moment of resistance for all elements. What might be wrong? How to deal with the error part of this? How do you design a ring beam foundation for chimney with slant elements/ring beam? Do you have any example on youtube?
@mohammedmurtuza144
@mohammedmurtuza144 2 жыл бұрын
Even I have same doubt
@saivamsi1381
@saivamsi1381 5 жыл бұрын
I was waiting for the wind load effects for the whole time
@phanikumar1817
@phanikumar1817 2 жыл бұрын
Why wind load is not assigned May I know the reason sir ???
@jayashreebhosekar9714
@jayashreebhosekar9714 2 жыл бұрын
Doubts are not answered. Normally, chimneys in power station plants are connected to flue gas outlets which require openings of matching sizes. How to model the openings and design the structure? There are intermittent platforms to support steel flues. How the platforms are to be modelled and designed with temperature stresses?
@barryallen995
@barryallen995 4 жыл бұрын
This is not a chimney, it's a cooling tower
@ksmbuildtechkumbarconstruc7742
@ksmbuildtechkumbarconstruc7742 4 жыл бұрын
its not chimney its a cooling tower..
@folivora9140
@folivora9140 4 жыл бұрын
Sirr can i have ppt for this pls
@civilengineeringbyshravan9596
@civilengineeringbyshravan9596 4 жыл бұрын
Sorry I don’t have
@subhanasamad3816
@subhanasamad3816 Жыл бұрын
@@civilengineeringbyshravan9596 please tell, how you have assumed the value for temperature load? is there any criteria to assume temperature load value?
@harshazurange876
@harshazurange876 Жыл бұрын
This vdo is of no use. Just uploading anything irrelevant. Wind load is not shown?
@omygod1590
@omygod1590 4 жыл бұрын
Kuch bhi upload. Krna
@civilengineeringbyshravan9596
@civilengineeringbyshravan9596 4 жыл бұрын
Definitely
Earthquake analysis in STAAD Pro by IS code
13:07
Civil Engineering by Shravan
Рет қаралды 35 М.
Я сделала самое маленькое в мире мороженое!
00:43
Tower Design by STAAD Pro V8i Software
15:24
Civil Engineering by Shravan
Рет қаралды 34 М.
Elevated Rectangular Water Tank Design by STAAD Pro V8i Software
15:11
Civil Engineering by Shravan
Рет қаралды 31 М.
Analysis and Design of Rectangular Water Tank Resting on Ground in STAAD Pro connect
14:13
Structural Engineering by Umesh Vazurkar
Рет қаралды 13 М.
Circular tank modelling in STAAD.Pro Physical Modeler
12:19
Madhan Elumalai
Рет қаралды 10 М.
Skyscraper building design by using STAAD Pro V8i Software
17:36
Civil Engineering by Shravan
Рет қаралды 9 М.
Steel Building Design by using Staad Pro V8i Software
18:04
Civil Engineering by Shravan
Рет қаралды 60 М.
Generating Wind Loads for Other Structures in STAAD.Pro
17:28
Bentley Structural
Рет қаралды 11 М.
VERTIVAL VESSELS FOUNDATION DESIGN 01
23:15
Structures Pro
Рет қаралды 447
Generating Load Combinations in STAAD.Pro
9:21
Bentley Structural
Рет қаралды 2,4 М.