No video

Basic Rules for Lapping length in Column - Lap length in RCC Column

  Рет қаралды 224,093

Civil Engineers

Civil Engineers

Күн бұрын

#CivilEngineers
Lapping length for column
what is lapping length in column
dia of lapping length
formula of lapping length

Пікірлер: 160
@sanjeevapampana4535
@sanjeevapampana4535 3 жыл бұрын
Correction please,50x25 is 1250 and not 1270 which you specified.
@sulemansikander5161
@sulemansikander5161 7 ай бұрын
Yes
@U.W265
@U.W265 Жыл бұрын
I really like your approach, best tutor ever, keep it up sir
@pradeepbharti6643
@pradeepbharti6643 4 жыл бұрын
Your video is very important for all fresher civil engineers
@mohantisso4234
@mohantisso4234 Жыл бұрын
very very nice explaination
@karanparihar8238
@karanparihar8238 4 жыл бұрын
Yr Mai new hu es field Mai..... Or Apki video bhout ache lgte h or Bhout Kuch Seekhne ko bhe milta h sir.. Thanku soo much sir
@CivilEngineerss
@CivilEngineerss 4 жыл бұрын
welcome bro
@salmansomroo573
@salmansomroo573 4 жыл бұрын
Sir khah sy ho
@binodpoudyal983
@binodpoudyal983 4 жыл бұрын
U have good knowledge to give lecture in civil subjects .l always with ur tution.
@er_noyda9613
@er_noyda9613 4 жыл бұрын
@9:18 25×50= 1270 that is wrong 25×50=1250 OK
@johnchiao4804
@johnchiao4804 4 жыл бұрын
hahahaha!! what is that?????
@er_noyda9613
@er_noyda9613 4 жыл бұрын
@@johnchiao4804 .awwwww broooo I'm joking 😡😂😂😡
@KGNBOYSCREATION
@KGNBOYSCREATION 4 жыл бұрын
Right bro mai bhi yhi bolne wala tha
@MAnas-el6cd
@MAnas-el6cd Жыл бұрын
Excellent video. Keep it up.
@AhmadAryan2013
@AhmadAryan2013 Жыл бұрын
Question about rule 2: To find over lap length, Do we use lesser dia or the top rebar dia?
@Kushkamili
@Kushkamili 2 жыл бұрын
Engineer thanks for the lesson
@moddycontris5672
@moddycontris5672 2 жыл бұрын
Thanks for the lesson, I have got a lot of idea brother, God bless u,
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Thanks For Teaching Sir (50 x 25) = 1250
@itsahmad936
@itsahmad936 4 жыл бұрын
Nice video very helpful But u have small mistake 50*25=1250 not 1270
@khademulmursalin9898
@khademulmursalin9898 4 жыл бұрын
50*25=1250.check it again
@tapasbhunia8895
@tapasbhunia8895 2 жыл бұрын
Bro focus the concept.
@sanjeevayadav4146
@sanjeevayadav4146 4 жыл бұрын
Keep rocking performance sir,it will be useful for each and every civil site engineer, please upload videos sir in structural and plumbing and electrical and waterproofing.
@nuwagabacollins6837
@nuwagabacollins6837 10 ай бұрын
Best Engineer yes sir sir❤
@tariqmir1401
@tariqmir1401 3 жыл бұрын
Very good knowledge thanks brother
@Bhattnadim
@Bhattnadim 3 жыл бұрын
Awesome explanation bro !!
@agiti
@agiti Жыл бұрын
i like your vedios but u can make good amount of views if u use some modeling vedio for this lapping case
@dulhapur
@dulhapur 3 жыл бұрын
Clear Height between plinth beam top and roof beam bottom-11 feets Zone-A-11/4=33 inches Zone-B-11*12-66=132 -66=66 inches There are 6 bars 16mm@4,12mm@2 At zone B top- 2 no of lappings At zone B middle(30 inch below top lapping points)-3 no of lapping At Zone B bottom (30 inch below middle lap point)-1 lapping Whether the above arrangement is allowble? Whether lintel tie beam can be provided any zone? What if lintel tie beam falls on zone-A top area?
@agiti
@agiti Жыл бұрын
guys i gat some real question i need to get only clear 25cm over my ready made columen reinforcement wichnos 14mm diameter having 6 bars 20x30 mm dimesion . so should i use 1.3 factor when making the overlapment?
@nivruthi
@nivruthi 4 жыл бұрын
Sir , if we hv to join the bars above 36 dia what we will do...,sir and also plz explain tilt bars on other video if possible ,based upon situation ,so im following ur videos,by this i can grab.tq so much sir.
@harikahoney3816
@harikahoney3816 4 жыл бұрын
If dia is more than 36 then we go for couplings....
@nivruthi
@nivruthi 4 жыл бұрын
@@harikahoney3816 tq. Harika !
@Dannyndangili
@Dannyndangili 2 ай бұрын
Please provide a video on how to know the number of bars needed in a slab
@donaldcharles1535
@donaldcharles1535 4 жыл бұрын
Great job . Very informative.
@anandreddy953
@anandreddy953 4 жыл бұрын
Well explain bro..thank u
@henrygoltiano4716
@henrygoltiano4716 4 ай бұрын
Very helpful
@pradipadhikari3078
@pradipadhikari3078 3 жыл бұрын
If all diameter bar of column is not same than what lapping length should we kept??
@manikantakarri3317
@manikantakarri3317 4 жыл бұрын
Why we provide c/c distance is 1.3 times of lapping length
@puiteakhenglot4537
@puiteakhenglot4537 10 ай бұрын
Sir i have one question,what is the. Formula for 10mm 12mm,16mm and 20 mm Like you said in this video 20 mm is 50d
@nickma8049
@nickma8049 4 жыл бұрын
What if lapping length exceed lapping zone how would you deal with it ? Let say Hn is 3.3m and diamater of rebar 20mm then Lapping length is 1m and lapping zone is only 1.65m but rebars should be 0.3*lapping length apart with each other
@aliqadri4672
@aliqadri4672 2 жыл бұрын
What you mean by hn..??
@huzaifkhaliqhuzaifkhaliq4367
@huzaifkhaliqhuzaifkhaliq4367 11 ай бұрын
Great sirrrrrr
@Iitgstr1
@Iitgstr1 4 жыл бұрын
Thanks Bro 👌 for useful information,
@neelakandapillai3072
@neelakandapillai3072 9 ай бұрын
Excellent explanation
@homendrapandey5708
@homendrapandey5708 4 жыл бұрын
God bless you n yur job,sir
@edwardarikpe9403
@edwardarikpe9403 6 ай бұрын
Please is it proper for lapping in foundation before DPC level?
@Axumman
@Axumman 2 жыл бұрын
some times you said the formula is 24d and sometimes 50d which is the right one. the same thing to beam L by 8 and L by 4. very confusing
@Muleaddis
@Muleaddis 3 жыл бұрын
Tnx for ur video , but i have a question that on the previous video u said the lapping length is 40D but now u said 50D ....which one is right
@bharatsinghrathod4968
@bharatsinghrathod4968 3 жыл бұрын
50 is right
@altamashshaikh2703
@altamashshaikh2703 2 жыл бұрын
It is not fixed, it varies for different columns...It is given in structural drawing
@islamicofficial1056
@islamicofficial1056 2 жыл бұрын
40D is for slab only and 50D should be for tensile zone of beam or slab
@girishhiremath4066
@girishhiremath4066 3 жыл бұрын
Sir 50D for 25mm dia is 1250
@vinilbrdbro5140
@vinilbrdbro5140 4 жыл бұрын
Good video. Thanks
@kevinombock9536
@kevinombock9536 3 жыл бұрын
Then also talk about the stirrups at the lapping zone of the column
@jeyakumar9194
@jeyakumar9194 3 жыл бұрын
Sir good and explain the labing Jone
@muhamedsedik1629
@muhamedsedik1629 4 жыл бұрын
For diff. diameters. Do we take the lesser or the top?
@afonrinwoolubunmipius6881
@afonrinwoolubunmipius6881 3 жыл бұрын
Well done pls. Show some practical examples
@mohammedafsal5876
@mohammedafsal5876 Жыл бұрын
If column have 8 bars. And how many bars want 1.3 times of dia length.
@ismailfaleye6060
@ismailfaleye6060 3 жыл бұрын
What is the purpose of the 6D little length and also what do u mean by plinth level
@khalifaalnaamany9330
@khalifaalnaamany9330 10 ай бұрын
Assalaam Alleikum brother, i need your help i have build a foundation of 3 store building, the problems are some of the steel bar exposed from the foundation beam are shorter than what is required are shorter than 50cm the steel sizes are 16mm, the formula of lapping 45d gives 72cm and some exposed bar are less than 50cm, how can i solve this problem.. Thank you
@dulhapur
@dulhapur 3 жыл бұрын
For finding A zone and B zone in coloumn only two floor beams are considered,is not lintel tie beam required to considered?
@abdurrahim3605
@abdurrahim3605 3 жыл бұрын
it is very important
@jasvirkumar5817
@jasvirkumar5817 4 жыл бұрын
In which situation or circumstances we can change dia of bar. Is it safer.
@sheikhhafiz8325
@sheikhhafiz8325 4 жыл бұрын
Why lapping is not provided for steel bar havind dia>36mm, what is the reason
@islamicworld1477
@islamicworld1477 4 жыл бұрын
Very informative vidoe sir
@mangmang1532
@mangmang1532 3 жыл бұрын
Wa alaikum salam Broo..indonesia
@vigneshpandiyan8231
@vigneshpandiyan8231 4 жыл бұрын
Bro you have given the lap bend up length as 6d, can you say at what angle it must bend or is there any formula ?
@johnchiao4804
@johnchiao4804 4 жыл бұрын
i didnt see in the construction site doing like that why??
@tofansahu4015
@tofansahu4015 4 жыл бұрын
Again thank Brother
@aliqadri4672
@aliqadri4672 2 жыл бұрын
Sir is that 1.3 is for stagered bar in colums.??
@rajeshsaha11r
@rajeshsaha11r 4 жыл бұрын
Nice explain but is code recommend after 32 mm dia of bar lapping not 36
@aliqadri4672
@aliqadri4672 2 жыл бұрын
Sir 6D is for that any bar wich we gonna tilled ???
@dailyhacks2244
@dailyhacks2244 4 жыл бұрын
Bro isn't the lapping length more, means I haven't seen they provide 1.2m lapping length in any site and 6d (250)is bit more
@invisiblehovercraft3218
@invisiblehovercraft3218 3 жыл бұрын
Yes
@HabiburRahman-xt2gl
@HabiburRahman-xt2gl 4 жыл бұрын
Do not allow an advertisement in the technical educational teaching of your good video. It seemed to be very worst.
@ijazmuhammad8399
@ijazmuhammad8399 2 жыл бұрын
25×50=1250 mm and now we need in meters. 1250÷1000mm in a meter=1.25m overlap comes here.
@panneerselvam4161
@panneerselvam4161 3 жыл бұрын
Sir actually 4 coloumn rods 2 rod same height and another 2 rod c/c distance 1.3*50d height correct pls tell
@muktaramhalder9882
@muktaramhalder9882 2 жыл бұрын
Correction plz,,,50*25,=1250mm,,,but you,,are, showing,,,1270mm,,,why,,,?
@huggituppa2544
@huggituppa2544 4 жыл бұрын
If number of bars are more than 8 how can provide 1.3 times dist bitween 2 laping centers
@paklahisap2646
@paklahisap2646 3 жыл бұрын
In the other Video you put 45D and in this 50D for lapping length
@michaelmelocoton8197
@michaelmelocoton8197 3 жыл бұрын
25x6= 150..sir is it in centimeters or millimeter? Hoping for your answer..
@mohammedabdulwahab2922
@mohammedabdulwahab2922 3 жыл бұрын
Millimetres
@lokpalmore2296
@lokpalmore2296 2 жыл бұрын
How to provide other bar
@Anjo1515
@Anjo1515 4 жыл бұрын
Thank you bro.
@syedabdulaleem5299
@syedabdulaleem5299 2 жыл бұрын
location not mention betweem beam/slab
@rajashehzad8739
@rajashehzad8739 3 жыл бұрын
If top steel is 24 mm dia and bottom steel dai 20 mm dia then which one we take for finding lapping length
@mohammedabdulwahab2922
@mohammedabdulwahab2922 3 жыл бұрын
Actually we take lesser dia of bar not top dia of bar👍
@premshankarmahto1853
@premshankarmahto1853 4 жыл бұрын
From UAE sir
@samahmadoke8704
@samahmadoke8704 4 жыл бұрын
Syukron . .
@behappy6486
@behappy6486 4 жыл бұрын
Upload bbs for slab and continuous beam
@tofansahu4015
@tofansahu4015 4 жыл бұрын
Thanks Brother
@bagusbudi3018
@bagusbudi3018 2 жыл бұрын
where is the proper lapping position of the column span? and why?
@abdurrahim3605
@abdurrahim3605 3 жыл бұрын
thanks
@sulemanahmad4318
@sulemanahmad4318 4 жыл бұрын
6D wala concept clear nhi hua... 6D bht zyada nhi hojye ga requirment se ?
@rathodchirag3354
@rathodchirag3354 4 жыл бұрын
How we can find length above tilt bar plz share something about this
@Lala-w5e
@Lala-w5e 4 жыл бұрын
سر پختو کی ھم یو چینل شروع کئیی د سول انجینئر پہ بارہ کئ۔
@wilhymticala3044
@wilhymticala3044 3 жыл бұрын
Sir. What it means RCC?
@manikantakarri3317
@manikantakarri3317 4 жыл бұрын
Why we take lesser dia
@CKCREATIONSSTATUS
@CKCREATIONSSTATUS 4 жыл бұрын
Bro meri ghar par 1 bu culomn beem nehi he upar kesa ghar koru Please reply
@christopherantony4137
@christopherantony4137 3 жыл бұрын
What could happen if we provide lapping length in the same point?
@anandopohtam7728
@anandopohtam7728 3 жыл бұрын
At the same point Buckling may occur
@EngNoora-tc2rb
@EngNoora-tc2rb 3 жыл бұрын
I couldn't understand the fourth rule ☹, can you explain more
@khansami8882
@khansami8882 4 жыл бұрын
Good g
@jayeshjayaram826
@jayeshjayaram826 3 жыл бұрын
tnku sir
@shankarm6812
@shankarm6812 3 жыл бұрын
what is 50 and 6 plz explaned
@chennareddyindla2349
@chennareddyindla2349 2 жыл бұрын
24mm will not available in market. After 20mm next available is 25 mm only.
@binodkumarranjit219
@binodkumarranjit219 4 жыл бұрын
50 * 25 = 1250
@rosanmaharjan6811
@rosanmaharjan6811 2 жыл бұрын
Sir I think ur calculation is not practical because laping zone not to be a zone and 1.3m different means how possible in zone b
@sourabhKumar-jc6ni
@sourabhKumar-jc6ni 4 жыл бұрын
Nice
@zackliwanagan8219
@zackliwanagan8219 3 жыл бұрын
common how much lenght is the lepin lent!! i am waiting!!
@studiosaimedia8459
@studiosaimedia8459 2 жыл бұрын
50x25=1250, not 1270
@SuperMoonITWorld
@SuperMoonITWorld 3 жыл бұрын
Sorry 50*25=1250
@bharatsinh8540
@bharatsinh8540 4 жыл бұрын
But nice video
@masteruni7280
@masteruni7280 3 жыл бұрын
Everything is ok
@ashokaashoka1558
@ashokaashoka1558 2 жыл бұрын
Sar transletion kannad
@saipradhan6895
@saipradhan6895 2 жыл бұрын
50*25=1250 mm
@rkchitrajeet4366
@rkchitrajeet4366 3 жыл бұрын
Very unfortunate for unable to multiple correctly
@gursimranjotsingh8896
@gursimranjotsingh8896 Жыл бұрын
It's 50 x 25 = 1250 not 1270
@narayananarjunan814
@narayananarjunan814 2 жыл бұрын
A
@pokeoffcha
@pokeoffcha Жыл бұрын
50x25=1250
@mohammadyusuf9161
@mohammadyusuf9161 2 жыл бұрын
No sir 1250 mm hoga
@AdityaSharma-pj1jp
@AdityaSharma-pj1jp 4 жыл бұрын
25*50=1250mm
10 Basic Rules of Column Design -  Don't Forget Basic Rules of RCC Column
13:09
When you discover a family secret
00:59
im_siowei
Рет қаралды 20 МЛН
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 164 МЛН
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 10 МЛН
wow so cute 🥰
00:20
dednahype
Рет қаралды 30 МЛН
What is Lap Length?
5:27
Engineering Motive
Рет қаралды 101 М.
Does Rebar Rust?
7:49
Practical Engineering
Рет қаралды 4,6 МЛН
Lapping Zone in Column Explained in Detail
4:04
Engineering Academy
Рет қаралды 22 М.
Types of Slab
8:57
Civil Engineering
Рет қаралды 181 М.
When you discover a family secret
00:59
im_siowei
Рет қаралды 20 МЛН