Lapping Formula for Beam Column and Slab | 24D - 45D and 50D for Lapping Length | Slab Beam Column|

  Рет қаралды 172,579

Civil Engineers

Civil Engineers

3 жыл бұрын

1) Construction cost of 1000 square feet House 2019? Cost of House Construction per square foot 2019
• Construction cost of 1...
2) Grade Of Concrete and water Cement Ratio
• Grade Of Concrete and ...
3) How to calculate Cement, Sand, and Aggregate for M20 concrete
• How to calculate Cemen...
4) Depth of Footing/Foundation and Reinforcement details in Foundation
• Depth of Footing/Found...
5) Maximum distance between two RCC columns?
• Maximum distance betwe...
6) Big Mistakes in RCC Slab - Lapping Mistakes
• Big Mistakes in RCC Sl...
play Lists :
Construction Videos :
• How to Chose Good Qual...
Construction Site Visit :
• New Exterior Design fo...
House Planning Play List :
• How to Study Column wi...
#CivilEngineers #CivilEngineering

Пікірлер: 81
@engrmahamudulhasanppappu3626
@engrmahamudulhasanppappu3626 3 жыл бұрын
Thanks for this vital information Sir. Love from Bangladesh ❤️
@mohammedahmedabdi5604
@mohammedahmedabdi5604 3 жыл бұрын
Thank you very much my pro b/c you gave us more advice and advantage for us in construction and also you showed us more mistakes in site plane while we are intire our homes, Thnkx
@MDMehrabHasanNishatKhan-qs6ff
@MDMehrabHasanNishatKhan-qs6ff 10 ай бұрын
In beam lapping zone for upper steels are along with columns and lower steels are middle portion of the beam. Which you showed in last beam drawing.
@pitamberpersaud7258
@pitamberpersaud7258 3 жыл бұрын
Thanks sir keep up the hard work of educating us.
@Life_is_Awesome_Civil
@Life_is_Awesome_Civil Жыл бұрын
Very nice
@lalnunthararoyte3439
@lalnunthararoyte3439 3 жыл бұрын
Very interesting and helpful video... From Mizoram
@lalakylas
@lalakylas Жыл бұрын
My dear friend you are suggesting to provide lapping at the supports for tensile zone of beam. But I suggest in tensile zone of beam you should provide within l/4 from the supports, Please correct your narration if you feel that what I said is correct.
@yathunanthan4142
@yathunanthan4142 3 жыл бұрын
ONE OF THE BEST VIDEO
@kapillohia5110
@kapillohia5110 3 жыл бұрын
Concepts clearing.....👍👍👍
@Sarayu3754
@Sarayu3754 3 жыл бұрын
Vertical= 50D Horizontal=60 D
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Thanks For Teaching 👌🏻👍🏻✌🏻
@michaelwellington1216
@michaelwellington1216 2 жыл бұрын
Thanks for sharing these information
@rufusimangbe6171
@rufusimangbe6171 3 жыл бұрын
Many thanks
@paklahisap2646
@paklahisap2646 3 жыл бұрын
75mm may be too short for lapping, I think minimum hooks length for column- Mizo Mistiri
@jaiharris6606
@jaiharris6606 3 жыл бұрын
Thanks a lot sir
@prabejalam487
@prabejalam487 3 жыл бұрын
Great job sir. Sir, if we provide 50% rebars lapping at l/4 then what we will do for next 50% rebars ? it's like for next 50% l/4 from lapping area or anything else?
@AlaHamoudi-ku8pj
@AlaHamoudi-ku8pj Жыл бұрын
Thank you very much
@EngNoora-tc2rb
@EngNoora-tc2rb 2 жыл бұрын
Your explain to beam lapping in bottom portion in this video different from your explain for beam also in another video. I got dizzy 😵 Noora from Iraq 🇮🇶
@SandeepSingh-uf4qp
@SandeepSingh-uf4qp Жыл бұрын
Great video sir
@huzaifkhaliqhuzaifkhaliq4367
@huzaifkhaliqhuzaifkhaliq4367 9 ай бұрын
Your acent is really gd sirr
@lalsawirema1383
@lalsawirema1383 3 жыл бұрын
Good sharing 🙏
@maslebahmad9561
@maslebahmad9561 3 жыл бұрын
Very very helpful video sir nd thank u so much sir
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
👍👍
@mominulislam7130
@mominulislam7130 2 жыл бұрын
Thanks sir....
@abdurrahim3605
@abdurrahim3605 2 жыл бұрын
Thanks
@muluguseshu689
@muluguseshu689 10 ай бұрын
Very nice explain
@nkwetatibet1774
@nkwetatibet1774 2 жыл бұрын
Thank sir l have been following your lecture for six months and I have learned alot
@reshitabish9149
@reshitabish9149 2 жыл бұрын
Thank u sir
@user-zp1iy9vi5y
@user-zp1iy9vi5y 7 ай бұрын
Nice lecture
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
Good video👍👍
@bernardigbonekwu7498
@bernardigbonekwu7498 2 жыл бұрын
Can you talk about mass concrete slabs calculations?
@venkatlalith4741
@venkatlalith4741 3 жыл бұрын
Sir at bottom portion the lapping we can not do in beam column joint (weak portion) why you said in beam column joint can you please explain.. 🙏
@cyrilthomasthomas6714
@cyrilthomasthomas6714 Жыл бұрын
Super sir
@SalmanKhan-tj1sw
@SalmanKhan-tj1sw Ай бұрын
Bro .. your vedio is very good but in beam i think you are mistaken ..... at the top extra bars should be at the corners of beam and in the bottom side you will provide in middle
@waswavicent2433
@waswavicent2433 11 ай бұрын
Too good yhanjs
@mathi328
@mathi328 2 жыл бұрын
Sir can u show the differences of lintel beam,roof beam,concealed beams
@DJVicky126
@DJVicky126 3 жыл бұрын
GOOD SIR
@muneebbahadar2419
@muneebbahadar2419 2 жыл бұрын
Can we use this formula if the dia of bars is in inches
@spanky9067
@spanky9067 3 жыл бұрын
No need for different color marker, save your focus and use 1 black marker.
@saifansari2049
@saifansari2049 2 жыл бұрын
24D,45D,50D and 60D Formula for leaping length Column Beem and Slab Sir I understand D for daya for steel But not understand 24,45,50 and 60 So please explain next video
@avinashjha1494
@avinashjha1494 Жыл бұрын
Sir if lapping of column comes in slab area then what is the solution pls explain
@md.robiulislam8613
@md.robiulislam8613 3 жыл бұрын
WoW your teaching style. I like this style.
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
👍👍
@saltanatkhan6246
@saltanatkhan6246 3 жыл бұрын
Walekum Assalam Sir.
@udaykumar-pu8zf
@udaykumar-pu8zf 3 жыл бұрын
sir you teach about lapping length in 12 technical terms the lapping should not be less 36mm but why you tech lapping length 75 mm
@Chris-Daniel
@Chris-Daniel 3 жыл бұрын
Nice Engineer
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
👍
@HamzaKhan-rc5gt
@HamzaKhan-rc5gt 3 жыл бұрын
How many grade of steel explain grades
@Mykeysl
@Mykeysl 3 жыл бұрын
Is this valid only for indian standrads or any?
@twizteddreamz4095
@twizteddreamz4095 3 жыл бұрын
Trying to make a one bed/bath 14x40 with 4 foot porch on front please help with interior wall thickness
@88maxdon
@88maxdon 2 жыл бұрын
Interior wall can be 4 inches
@palebluedot8733
@palebluedot8733 Жыл бұрын
Did your university use IS code while teaching? What university is that?
@jamalanasar1894
@jamalanasar1894 3 жыл бұрын
Aci codes plz
@constructionworld9885
@constructionworld9885 Жыл бұрын
Zones sir?
@vishojitsen6613
@vishojitsen6613 3 жыл бұрын
75 mm is minimum hook length but it is not min. Lap length
@naveenk7062
@naveenk7062 Жыл бұрын
Our least bars is 6 mm
@armyofficermanishsharma5039
@armyofficermanishsharma5039 3 жыл бұрын
good morning
@user-pn1zb5dx6x
@user-pn1zb5dx6x 3 жыл бұрын
Love From israel :)
@rajcivlengtraininginstitute
@rajcivlengtraininginstitute Жыл бұрын
Bhai for column lap should be provided staggered.. please not this point...and for slab lap please explain with diagram as explained for beam and column
@feedmyego8874
@feedmyego8874 11 ай бұрын
joggle needed for 12mm dia bars in column?
@SHUBHAMSINGH-df4sg
@SHUBHAMSINGH-df4sg 10 ай бұрын
72mm
@mohammedhussen283
@mohammedhussen283 3 жыл бұрын
Do you have a book for sale to help us to buy it concerning this course
@cinerapture
@cinerapture 3 жыл бұрын
I got it
@saifansari2049
@saifansari2049 2 жыл бұрын
Sir I understand L/4 and H/5 But not understand 24,45,50 and 60
@zulkaifkhan3563
@zulkaifkhan3563 2 жыл бұрын
I saw your another you told that for column .24d Now here you say that 45d .
@zulkaifkhan3563
@zulkaifkhan3563 2 жыл бұрын
Which one is correct
@amjadhussain7097
@amjadhussain7097 Жыл бұрын
Better you provide details in your native language it's good
@muhammadhashim73
@muhammadhashim73 Жыл бұрын
کالم کے اوپر کونسی سلیب ہوتی ہے؟؟
@MohsinAli-ub6dz
@MohsinAli-ub6dz 7 ай бұрын
Dear Please correct the mistakes dear regarding lap length location ,positive and negative moments location in beam.
@Carhashpk
@Carhashpk 3 жыл бұрын
Urdu ma please
@armyofficermanishsharma5039
@armyofficermanishsharma5039 3 жыл бұрын
assalam valikum
@riyazf8125
@riyazf8125 Жыл бұрын
Plz explaine in Hindi
@ashokaashoka1558
@ashokaashoka1558 2 жыл бұрын
Sir tech or translation kannada
@muhammadhashim73
@muhammadhashim73 Жыл бұрын
میں آپکا دکھ سمجھ سکتا ہوں 😫
@RahulPatil-kk6sz
@RahulPatil-kk6sz Жыл бұрын
हिंदी मे करते तो अच्छा होता.
@usamasyed7913
@usamasyed7913 4 ай бұрын
Aby urdu man samjha day bhai Angrez wasay bhi parhay likhay hotay han,,,,,
@anwarayub1117
@anwarayub1117 Жыл бұрын
phone no
@kaakib8841
@kaakib8841 2 жыл бұрын
Pehle aap thoda padh lo... Phir padhao.... Galat info mat do
@civil_boy_-ym1wz
@civil_boy_-ym1wz 2 жыл бұрын
Thank you sir
@durableconstructiong.c3036
@durableconstructiong.c3036 2 жыл бұрын
Thanks
@shijitk8445
@shijitk8445 Жыл бұрын
Thank you sir
Basic Rules for Lapping length in Column - Lap length in RCC Column
13:34
KINDNESS ALWAYS COME BACK
00:59
dednahype
Рет қаралды 151 МЛН
Does size matter? BEACH EDITION
00:32
Mini Katana
Рет қаралды 18 МЛН
How to produce Pure Water using an Ionic Reach & Wash System
8:05
What is Lap Length?
5:27
Engineering Motive
Рет қаралды 100 М.
Lapping Zone in Column Explained in Detail
4:04
Engineering Academy
Рет қаралды 22 М.
The Man Who Solved the World’s Most Famous Math Problem
11:14
Newsthink
Рет қаралды 653 М.
Size of Beam , Size of Column and Spacing between Two Column
13:01
Civil Engineers
Рет қаралды 363 М.
Formula for Slope of Stairs | How to Calculate Slope of Stairs?
5:23
Civil Engineers
Рет қаралды 416 М.
Two Way Slab Reinforcement
9:08
AK Skills & Solutions
Рет қаралды 860 М.
Rules of Beam Reinforcement Design
13:37
Civil Engineers
Рет қаралды 124 М.
KINDNESS ALWAYS COME BACK
00:59
dednahype
Рет қаралды 151 МЛН