No video

Where we Can Provide Lapping in Beam and Slab ? Best Zone for Lapping in Beam

  Рет қаралды 38,440

Civil Engineers

Civil Engineers

Күн бұрын

1) Construction cost of 1000 square feet House 2019? Cost of House Construction per square foot 2019
• Construction cost of 1...
2) Grade Of Concrete and water Cement Ratio
• Grade Of Concrete and ...
3) How to calculate Cement, Sand, and Aggregate for M20 concrete
• How to calculate Cemen...
4) Depth of Footing/Foundation and Reinforcement details in Foundation
• Depth of Footing/Found...
5) Maximum distance between two RCC columns?
• Maximum distance betwe...
6) Big Mistakes in RCC Slab - Lapping Mistakes
• Big Mistakes in RCC Sl...
play Lists :
Construction Videos :
• How to Chose Good Qual...
Construction Site Visit :
• New Exterior Design fo...
House Planning Play List :
• How to Study Column wi...
#CivilEngineers #CivilEngineering

Пікірлер: 34
@MasterCivilEngineering
@MasterCivilEngineering 3 жыл бұрын
Master your civil engineering knowledge here📖📖📖
@maberikinstink9407
@maberikinstink9407 2 жыл бұрын
You are contardicting yourself Mr. Engineer because in your video titled LAPPING FORMULA FOR BEAM COLUMN AND SLAB uploaded on 2-15-21 you said that lapping in a continuous beam should be done at the support but in this video you are saying you cannot do lapping at the support. What is true? Will wait for your reply on this because i am confused. Been an avid follower of your videos. Thank you.
@devsouting5695
@devsouting5695 2 жыл бұрын
I also have the same question
@PatrickInCayman
@PatrickInCayman 3 жыл бұрын
Excellent, thank you!
@handsam5
@handsam5 2 жыл бұрын
Compression zone is the best place for lapping length.
@burtreynolds4917
@burtreynolds4917 2 жыл бұрын
Thank u sir for this video continue your work... god bless u
@md.mizanurrahmanaru3128
@md.mizanurrahmanaru3128 3 жыл бұрын
Sir love u,,,,,,,From Bangladesh,,,,,,,
@paklahisap2646
@paklahisap2646 3 жыл бұрын
In the other Video you said for Compression Zone lapping length 24D.
@mjk568
@mjk568 2 жыл бұрын
It is minimum
@shashangkipgen6065
@shashangkipgen6065 3 жыл бұрын
professionalism is 1000
@agiti
@agiti Жыл бұрын
good for students & some pro
@h.alhaidre9020
@h.alhaidre9020 3 жыл бұрын
Excellent from iraq
@BA-kl6bv
@BA-kl6bv 2 жыл бұрын
Pls. lap location for raft and swimming pool and grade slab connect with tie beam / with out connect with beam
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Thanks For Teaching Sir
@armyofficermanishsharma5039
@armyofficermanishsharma5039 3 жыл бұрын
From india
@mohammedafsal5876
@mohammedafsal5876 Жыл бұрын
What about plinth beam. Is there is any change in compression and tension zones
@sgpfamilysgpfamily844
@sgpfamilysgpfamily844 Жыл бұрын
Sir people are telling the beam lapping should given in column middle . Which is correct
@jeyakumar9194
@jeyakumar9194 3 жыл бұрын
Thanks sir pls explain the best laping for colum Jone
@keshavamurthymn2939
@keshavamurthymn2939 3 жыл бұрын
Excellent explain sir
@petermapp5988
@petermapp5988 3 жыл бұрын
Born to teach
@anishanishkt5284
@anishanishkt5284 3 жыл бұрын
Your previous video the lapping zone given at support why
@orangkota4010
@orangkota4010 3 жыл бұрын
Yea thats what i want to know too
@shivamurthykattennavar8233
@shivamurthykattennavar8233 3 жыл бұрын
which one is correct sir this or either previous video?
@abdurrahim3605
@abdurrahim3605 3 жыл бұрын
Thanks
@nikkofebryanto1486
@nikkofebryanto1486 3 жыл бұрын
What happen when you didn't put leaping on top sir?
@lismanpermana8218
@lismanpermana8218 2 жыл бұрын
sir.. where is lapping zone for distribution bar/side face bar.. ?
@najibaibrahim3097
@najibaibrahim3097 3 жыл бұрын
That means l/4 not true???? That is just for stirupp ….After l/3 is suitable for lapping the top
@armyofficermanishsharma5039
@armyofficermanishsharma5039 3 жыл бұрын
Good morning sir
@xaviahmad6368
@xaviahmad6368 3 жыл бұрын
What is 2d mean?
@EngNoora-tc2rb
@EngNoora-tc2rb 3 жыл бұрын
It's mean 2 times the effective depth of beam . In another way = 2 × effective depth for beam (d). .Noora from Iraq 🇮🇶
@shivamurthykattennavar8233
@shivamurthykattennavar8233 3 жыл бұрын
What happened sir ur left hand..
@engrasgharbadshah9247
@engrasgharbadshah9247 Жыл бұрын
You living in Pakistan and using or referring IS code strange, you should be referring ACI rather than IS.
@gsaulakh9893
@gsaulakh9893 3 жыл бұрын
Sound or video alg alg chl rhe h
@irfanullah6540
@irfanullah6540 3 жыл бұрын
Sir tabyat mo snga dy
Basic Rules of Lapping in Beam   Reinforcement Lapping zone in Beams
6:47
白天使选错惹黑天使生气。#天使 #小丑女
00:31
天使夫妇
Рет қаралды 14 МЛН
Basic Rules for Lapping length in Column - Lap length in RCC Column
13:34
5 Important Rules of Beam Design Details | RCC Beam | Green House Construction
8:45
NHÀ XANH VIỆT NAM
Рет қаралды 2,1 МЛН
When a physics teacher knows his stuff !!
3:19
Lectures by Walter Lewin. They will make you ♥ Physics.
Рет қаралды 53 МЛН
Why Tunnels Don't Collapse
8:40
Practical Engineering
Рет қаралды 3,7 МЛН