1000W Inverter: How Many Batteries You Really Need

  Рет қаралды 77,297

Cleversolarpower by Nick

Cleversolarpower by Nick

Күн бұрын

Пікірлер: 115
@cleversolarpower
@cleversolarpower 5 ай бұрын
🎁 Free diagrams: cleversolarpower.com 📖 My best-selling book on Amazon: cleversolarpower.com/off-grid-solar-power-simplified 💵Use coupon code: clever6 to get 6% discount for Litime batteries: cleversolarpower.com/litime (cheaper than amazon)
@3sheds
@3sheds 9 ай бұрын
Thank you for simplifying and sharing your knowledge. As a direct result of your previous video, I have abandoned my Lead Acid, and moved to a Lithium to power my 1000w Inverter. It works perfectly. All I need now is for spring sunshine to come 🤣
@faisalalhashar5831
@faisalalhashar5831 2 күн бұрын
Hello, thank you for excellent and outstanding videos. I have a question, I have 4 100 Amps AGM batteries on my boat. I also have a Victron MultiPlus 2000VA and Digital Multi Control 200/200A GX. From your video, it seems that I will need an additional 400 Amps to cope with my 2000w inverter - right? My question is, until I do add the needed batteries can I still use 1000 w appliances in the current setup without the overheating or any other risks?
@2011italianoboy
@2011italianoboy 7 ай бұрын
Ok, I'm new to inverter, solar-powered, and batteries. Your video explained it well. I WAS going to get 3k watt inverter with just one LiFePO4, rated at 100a. I know now that I would need at least 3 100amp batteries to work with a 3k w inveter.
@cleversolarpower
@cleversolarpower 7 ай бұрын
Yes, I also made a video about how many batteries for a 3,000W inverter. You can check it out.
@jimmybrad156
@jimmybrad156 3 ай бұрын
might want to go 48v.
@budmartin3344
@budmartin3344 9 ай бұрын
To get 1000W from the AC output of the inverter, the input power to the inverter will be higher than 1000W due to the inverter efficiency, 80% is typical, so the current draw from the battery will be 83A/0.8 = 103A.
@cleversolarpower
@cleversolarpower 5 ай бұрын
Correct, when sizing wires and cables we use a 1.25 factor to account for this. I didn't include it in this video because it would make it more complicated.
@nattapongsookrojnirun5071
@nattapongsookrojnirun5071 Ай бұрын
very great video !!! at 2:42 what should we concern if we use 12V , 100ah lithium x 2 pleazzze ? or should it be better to use 12V 200ah ? cant figure it out that part , been watching this over 5 times now 😂
@cleversolarpower
@cleversolarpower Ай бұрын
You can have a 12V 200Ah battery. You will require less wires which is good. You still need two of them in parallel to make 12V 400Ah. But if you are buying new batteries i recommend getting lithium (lifepo4). they are cheaper as i have analyzed in my video about lead-acid vs lithium.
@gailmrutland6508
@gailmrutland6508 9 күн бұрын
*Clear and concise, KUDOS!*
@cleversolarpower
@cleversolarpower 9 күн бұрын
Glad you liked it!
@TUVIX3
@TUVIX3 9 ай бұрын
I like your video but I can't figure out how many batterys I need. I want to power a computer pulling 1500w at the wall at night. If I have a solar pannel charging the batterys during the day? Is it even posible to power for that amount of time?
@cleversolarpower
@cleversolarpower 9 ай бұрын
Check out my video about sizing an off grid solar system. It will tell you how.
@loumusa9124
@loumusa9124 4 ай бұрын
Thanks for the video. As a result I want to replace both my deep cycle 100amp lead acid batteries with 2 Lithium 100ah batteries. My inverter is a Sensata Technologies CSW1012 1000W Inverter. Will this set up work for my situation?
@cleversolarpower
@cleversolarpower 4 ай бұрын
Will work great. You will have to adjust the charging parameters of your charge controller to match the voltage of lifepo4.
@victorgallardo9763
@victorgallardo9763 8 ай бұрын
Thank you very much for the video, I am learning a lot, but it is not clear to me if a 200Ah (lithium) battery would be better than a 100Ah? Would it be more efficient?
@cleversolarpower
@cleversolarpower 8 ай бұрын
Having a larger battery will put less stress on the battery. One battery will draw 85A while a second battery in parallel will only draw 43A per battery. So you put less stress on the battery, leading to a longer lifespan.
@victorjoseph8948
@victorjoseph8948 7 ай бұрын
IF i only charge my lipo4 12v 100ah battery with solar panels i do not need the invertor right? for i just want to only charge the battery for augmenting my Bluetti EB3A 268Ahcapacity and have 1080 usable Wh with my EB3A battery. is this correct? or am i mistaking? 1080+268= approx 1300Wh. instead of just the 268 watts. since the EB3A has a charge controller mppt integrated.
@cleversolarpower
@cleversolarpower 7 ай бұрын
If you don't need AC, then you don't need an inverter.
@jerryndembeka7682
@jerryndembeka7682 10 ай бұрын
Please do another calculation video with 2000W inverter with 24V batteries. Your videos are very helpfully. Thank
@cleversolarpower
@cleversolarpower 10 ай бұрын
Thanks, I feel like repeating myself when I do that video. It's the same principle over again. 2000W on 24 will draw 83A. Lead acid needs to be 24v 400ah, and lithium 24v 100ah.
@Abiola-y3z
@Abiola-y3z 9 ай бұрын
Your videos are so succinct and serve as refresher for me as an experienced Solar PV Professional. However, this particular video needs reveal. For example, if an inverter is rated 12V/1000W (assuming 100% efficiency), it means it can supply max. 83A. Then a typical Lithium battery rated 12V/100AH at 1 C rate will draw maximum of 100A. The system will definitely overheat because what is required for the battery charging 100A is higher than what the inverter can supply which is 83A at 100% efficiency. Thanks.
@cleversolarpower
@cleversolarpower 9 ай бұрын
83A x 1.11 (efficiency of inverter) = 92A. Yes, the BMS will get warm, but that's what it's rated for.
@jab376
@jab376 8 ай бұрын
​@@cleversolarpower what happens if we use 4 x LifePO4 batteries with 1000 watts inverter? Will also overheat like Lead acid battery?
@JD-rp1fx
@JD-rp1fx 5 ай бұрын
Is that the required battery sizes if you run the inverter at max power? If your load is only say 200A (a fridge and some lights) you won't place a big draw on the battery, mostly inverter on idle.
@BK-gc1jm
@BK-gc1jm 26 күн бұрын
Hi I have a question A 2,500 pure inverter. how many 100 amp lifepo4 batteries will I need. otherwise a 2000 watt inverter. and a 3000 w inverter how many batteries.
@cleversolarpower
@cleversolarpower 25 күн бұрын
Follow the math in the video. I have made a video about a 3000w inverter as well.
@RobinMuric
@RobinMuric 2 ай бұрын
Can you tell me how many batteries I need for a 8000 watt inverter? I tried to start up a shallow well 110 water pump but it would not work. I only have 4 rv lead acid batteries in parallel. Do I need more? Thank you.
@cleversolarpower
@cleversolarpower 2 ай бұрын
You can repeat the calculations shown in this video to your own system. You will definitely need more than 4 lead acid batteries. Why did you even get a 8000W 12V inverter. Bigger is not better.
@RobinMuric
@RobinMuric 2 ай бұрын
@@cleversolarpower I found out that it is not an 8000 but a 4000/8000 peak.
@grahamjohnbarr
@grahamjohnbarr 3 ай бұрын
Ok, I'll start again. I have 4 x 12V x 300W In Series Parallel Solar Panels feeding into a Vevor 12V 60A Controller, feeding into 4x 12V x 120Ahr Batteries, In Series Parallel configuration, giving me 24V 240Ahr. The Batteries feed into a 12000/6000W Inverter. Will only having the 4 x 120Ah in Series Parallel create a problem, or do you think that will work ok?
@cleversolarpower
@cleversolarpower 3 ай бұрын
6000W/24V=250A, the max your batteries can deliver is 240A in a 2S2P configuration. So it will work. However, you should have better used a 48V system. Check my video 12,24 or 48V battery system.
@grahamjohnbarr
@grahamjohnbarr 3 ай бұрын
@@cleversolarpower Thank you.
@junior4246
@junior4246 6 ай бұрын
i have a 1000w Renogy inverter with a 280ah fogstar drift lithium battery is this any good ?
@jackfromthe60s
@jackfromthe60s 7 ай бұрын
I like your videos. I just received your free diadgrams and am working my way through them. On page 5 of the free diagrams you say a lithium battery can provide a current of 0.5C. But at 2:10 in this video you say a lithium battery can provide 1C. Can you please clarify?
@cleversolarpower
@cleversolarpower 7 ай бұрын
Some lithium batteries are rated for 0.5C, but nowadays, this is 1C. I will change the document. Thanks for notifying.
@brandonraybern9975
@brandonraybern9975 9 ай бұрын
400ah lifepo4 with 2000W intverter...should I experience any issues being that much more on my battery bank?
@cleversolarpower
@cleversolarpower 9 ай бұрын
2000W/12V=166A*1.25=208A If your bms can handle 200A, then it's ok.
@kasperoner6988
@kasperoner6988 3 ай бұрын
What if I’m using it on my truck a 1000w inverter and I’m connected to my alternator my inverter has 6 fuses on it. What size wire should I use? And I will be using my inverter only when my truck is running and the distance from alternator and the inverter is 6ft. So what size wire would I need?
@cleversolarpower
@cleversolarpower 3 ай бұрын
Probably 4awg welding cable. Check the manual of the inverter as well.
@robertcollins5713
@robertcollins5713 2 ай бұрын
Great info possible the first video I have been able to understand Thank you
@realflow100
@realflow100 6 ай бұрын
I have a super budget cheap universal brand 100 amp hour capacity 12 volt sealed agm lead acid battery paired with a 1000 watt pure sinewave inverter and it works beautifully. No problems. Never took the battery below 80% depth of discharge. and it handles loads like window air conditioners. vacuum cleaners. computers. and more. with no problems. powering it for a few hours. Doesn't get hot. Voltage drop is not a problem. I used thick 1/0 awg gauge cable so even under the load of a full size window air conditioner it powers it like it's not even there. It is about 3 years old and still works like new. I respect the batteries maximum capabilities by checking the manufacturers specifications on it. and it is fully capable of handling anything I throw at it when properly set up and used correctly. I use it as a backup emergency power generator setup. where it is kept charged and maintained when not in use. and fully charged and ready for use if there is a power outage or other emergency where we need significant portable power. it is very cheap and budget but works great.
@tedjelsema782
@tedjelsema782 6 ай бұрын
does battery amps effect pv controllers?
@bjarnenilsson80
@bjarnenilsson80 4 ай бұрын
Imigh be stupid but is thst fuse before or after the inverter? That is on the av or dc side
@cleversolarpower
@cleversolarpower 4 ай бұрын
There are no stupid questions, only bad teachers 😂. It's before the inverter on the DC side. Breakers are used on the AC side.
@user-qc6yq1jh4j
@user-qc6yq1jh4j 6 ай бұрын
how to tell what the battery is agm or lead acid or deep cycle or lifium ?
@cleversolarpower
@cleversolarpower 6 ай бұрын
The battery will tell you 😉
@user-qc6yq1jh4j
@user-qc6yq1jh4j 6 ай бұрын
that if the label is still there
@myronmoncur
@myronmoncur 9 ай бұрын
i have 2 24 V DC lead acid batteries is that enough for my 3000W inverter ?
@cleversolarpower
@cleversolarpower 9 ай бұрын
Most likely not. If the 24v batteries are 100ah each, then you should draw maximum 40amps. 40Ax24V=960W.
@myronmoncur
@myronmoncur 9 ай бұрын
so maybe go down to a 2500W inverter?@@cleversolarpower
@myronmoncur
@myronmoncur 9 ай бұрын
watching your video and doing some math (hopefully correctly lol) a 2000W inverter with my 2 24V Battery 100AH should be fine (1920 W) . Is this correct ?
@robertweekley5926
@robertweekley5926 9 ай бұрын
A "100 Ah" Lead Acid Flooded Deep Cycle Battery (Trojan SCS Series) is "Rated" at 20 Hours, meaning a "5 Amp Load" (20 Hours x 5A = 100 Ah)
@robertweekley5926
@robertweekley5926 9 ай бұрын
To get a Durable Setup, if you need to pull 100 Amps just divide 100 by 5 to get your battery count! (100/5=20) So that means 20 in Parallel *For a 12V Inverter*, or 4 in Series x 5 in Parallel if you use a 48V inverter. So 2 in Series x 10 in Parallel, for a 24V Inverter!
@PeterLGଈ
@PeterLGଈ 8 ай бұрын
Great content. 👍
@BenjieEng
@BenjieEng 9 ай бұрын
Thanks for this video... I've got the answer to my question 😂
@figuretech547
@figuretech547 6 ай бұрын
What bothers me here is that in all the calculations how can one tells factors like How long will the Inverter supply the load capacity How long the battery will take before it is full and of course how long before the battery charge controller or inverter shutdown when i reach my targeted depth of discharge. Please help
@cleversolarpower
@cleversolarpower 6 ай бұрын
That depends on your load analysis. Check my video about it.
@figuretech547
@figuretech547 6 ай бұрын
@@cleversolarpower please can you do a video about it Sir. I'm a big fan. Have almost watched all your videos
@Electronzap
@Electronzap 10 ай бұрын
Good info.
@cleversolarpower
@cleversolarpower 10 ай бұрын
Glad it was helpful!
@ashiepfrancis8503
@ashiepfrancis8503 8 ай бұрын
Please can I use 120ah battery and 2000w invater to power up 180w tv
@cleversolarpower
@cleversolarpower 8 ай бұрын
Yes, but make sure you follow the calculations in the video.
@ashiepfrancis8503
@ashiepfrancis8503 8 ай бұрын
Thank you
@ashiepfrancis8503
@ashiepfrancis8503 8 ай бұрын
How many watt solar panels are recommended for 2pc of 120ah battery
@davef.2329
@davef.2329 9 ай бұрын
Well done. Thanks.
@BenjieEng
@BenjieEng 9 ай бұрын
I have been using 12v 150ah lead acid battery on my 1000w inverter, and the results after 6 months, now, the battery drained in 30 minutes in 200w load.
@cleversolarpower
@cleversolarpower 9 ай бұрын
0.5h*200W=100Wh. Your battery can deliver 12V*150Ah*0.5=900Wh. So if the battery only delivers 100Wh while it should be 900Wh, then your battery is dead.
@evanemerson89
@evanemerson89 5 ай бұрын
Thankyou
@mmawar4825
@mmawar4825 5 ай бұрын
I need to install 1000 wat sostem 1 kw natery storage lothium please jelpe how to prosode woth dhe stiif i meed to by
@cleversolarpower
@cleversolarpower 5 ай бұрын
I just made a video about it.
@tlalotoani
@tlalotoani 3 ай бұрын
So, if I´m using my system to power 3 10w light bulbs and a 50w TV, Is the same? My guess is that IT ISN´T
@cleversolarpower
@cleversolarpower 3 ай бұрын
The total power consumed per day matters in watt hours.
@AlexanderRodriguez-ym7we
@AlexanderRodriguez-ym7we 2 ай бұрын
To play it safe, just get a more powerful one. It's better to be over than under.
@HendrikSteenkamp-l4b
@HendrikSteenkamp-l4b 8 ай бұрын
Cant i connet 2 inverter 1 500w and 1000watt up batery 12vlt 100ah
@cleversolarpower
@cleversolarpower 8 ай бұрын
if the inverters cannot communicate with each other, don't wire the outputs together.
@geraldgm1217
@geraldgm1217 4 ай бұрын
Awesome 👌
@nakorau
@nakorau 10 ай бұрын
a video on DCDC battey chargers. please.
@cleversolarpower
@cleversolarpower 10 ай бұрын
Thanks for the suggestion 🙏
@nakorau
@nakorau 10 ай бұрын
@@cleversolarpower i assume you could talk about alternator output amps, lithium and agm , charging rates and so forth. smart altrernators is a thing now with modern cars.
@markissboi3583
@markissboi3583 7 ай бұрын
Average person buys a good inverter to run off your car plugs into ciggie lighter socket & wonders why car catch fire :) draw on small wires bad hot like using a welder with an extension cord wound up on a spool Melts ive seen this happen in the 80s at work if we didnt make mistakes we wouldnt learn anything ok
@cleversolarpower
@cleversolarpower 7 ай бұрын
Better learn through a KZbin video than a burning car i guess.
@rocktech7144
@rocktech7144 10 ай бұрын
Take your four batteries and turn them into 2p2s for 24 volts. Use a 24volt inverter and smaller wire is needed.
@cleversolarpower
@cleversolarpower 10 ай бұрын
I have discussed that in my video about a 3000W inverter. If you have lead acid, you still need 4 in parallel to respect the C-rate. If you want a 24V system, then you need 8 batteries in a 4S2P configuration.
@rocktech7144
@rocktech7144 10 ай бұрын
@@cleversolarpower I thought you were talking about 1000w. I just use 8 230A lithium cells and they run my shop and cabin with 3000w.
@mynameisprivate158
@mynameisprivate158 10 ай бұрын
Yea but why can't I have 2 12v batteries connected to a 2000w inverter so the pull is 83w from each battery
@cleversolarpower
@cleversolarpower 9 ай бұрын
@@rocktech7144 3000W/24=125A (okay-ish) 230Ah*1C=230A -> under 125A, so C-rate is ok.
@cleversolarpower
@cleversolarpower 9 ай бұрын
@@mynameisprivate158 Your current will be 166A, which in my opinion is too much. It will work, but not as good as a 24V or even 48V system. I have a video about that upcoming.
@MegaCyrik
@MegaCyrik 10 ай бұрын
Im guessing you know better.. so... Why would you say lead acid is 0,2c and lithium 1c? My old lead is 0,33c but higher is quite common. I often run into 0,5c while browsing. Also lithium goes all the way up to 100c and probably higher. Some are lower than 1c thou. Most of my own are 3-5c. I'm just curious why you say 0,2 & 1c.. why not just teach people to examine their bats or examine what to buy.
@cleversolarpower
@cleversolarpower 10 ай бұрын
Checkout the data-sheet of the battery. Most lead acids are tested at C20 which is 0.2C. that is then the capacity. You can discharge quicker at a higher C rate, but then the capacity is reduced. Look at trojan battery data-sheet which shows it very clearly. Lifepo4 batteries are discharged at 1c and then the capacity is based on that discharge rate. Check my video about C rate.
@ferencszabo3504
@ferencszabo3504 10 ай бұрын
Cmon, you gonna deep discharge the batteries? 😅😅 The lead batteries are the worst, you can only discharge it for 25%, the rest of it 75% must remain in the battery! They are very inefficient! The Lithium has its own quirks of course!
@cleversolarpower
@cleversolarpower 10 ай бұрын
Lead acid should be discharged to 50%. Lead acid still has its applications, but lithium is cheaper in the long run.
@dadybig6522
@dadybig6522 2 ай бұрын
To long just say how many
@cleversolarpower
@cleversolarpower 2 ай бұрын
And learn nothing?
@cabracove
@cabracove 10 ай бұрын
Ok, first off, a 1000 watts is pretty useless. Get an inverter that will at least run a coffee maker.
@cleversolarpower
@cleversolarpower 10 ай бұрын
That's so American of you to say 😄 vans use less than 1000 watts.
@cabracove
@cabracove 9 ай бұрын
@@cleversolarpower 2000 watt inverter and 460AH of batteries in my van. My coffee maker pulls 1200 watts.
@adriaankoffiekar6442
@adriaankoffiekar6442 9 ай бұрын
My Coffee machine pulls 2500 watt and the inverter is 3kVa 48V - 16 lfp04 280ah Est. On time 25% VICTRON Multplus 2 GX 50mm2 automotive double shielded cables 2mtr x 2 I can hardly wait for the sodium cells to become reasonably affordable, especially considering their cold qualities.
@davef.2329
@davef.2329 9 ай бұрын
No trying to start any arguments with anyone, just convey some useful, practical info: Mr. Coffee Mini (5 cup model) draws 635 W when on the brew cycle, then becomes intermittent, as needed with the warming plate on. That 1/2-size machine, with a 1000 W CSWEI PSW inverter, 10 Ah MPPT charge controller, 100 Ah LiFePo4 (100 Ah BMS) and 150 W of solar panels has worked successfully without any other a/c input for the past year. We make a pot in the morning, another in the evening, and sometimes another in the mid-day. It's doable.
@cabracove
@cabracove 9 ай бұрын
@@davef.2329 Hey whatever works. I'm already running the fridge, I like to turn the diesel heater on in the morning, and maybe nuke a pastry with some butter to have with my coffee.. 1000 just won't cut it. Some of that stuff is 12V, but still....
@anjelinacao6565
@anjelinacao6565 3 ай бұрын
I have a 2000w continuous/ 4000surge power inverter and I am not sure what battery I need and if I need two of them . Please help ?! 🫠
@anjelinacao6565
@anjelinacao6565 3 ай бұрын
I’m trying to power this portable air conditioner 900w 8,000BTU
@cleversolarpower
@cleversolarpower 3 ай бұрын
It's best to use a 48V system for home applications. 12 or 24V for mobile. Don't rely on the surge protection of the inverter, this will probably not be correct. 900W/12V=75A*1.25=93A. At least a 100Ah battery.
@hotshotter4500
@hotshotter4500 3 ай бұрын
​@@cleversolarpowerf I buy a 2000 inverter and a 200ah lithium battery how long should I expect it to run a refrigerator that draws 500w?
@vcarvewood4545
@vcarvewood4545 3 ай бұрын
​@@hotshotter4500your fridge consumes 500W/12V=42A. What kind of monster fridge it is, but anyway. 200Ah/42A=5 hours. But remember that fridge works in cycles. You can multiply that time by 3, I think.
What Size Solar Panel to Charge a 12V Battery
6:09
Cleversolarpower by Nick
Рет қаралды 128 М.
How Many 12V Batteries for 3000W Inverter
15:26
Cleversolarpower by Nick
Рет қаралды 282 М.
風船をキャッチしろ!🎈 Balloon catch Challenges
00:57
はじめしゃちょー(hajime)
Рет қаралды 21 МЛН
The Singing Challenge #joker #Harriet Quinn
00:35
佐助与鸣人
Рет қаралды 8 МЛН
Миллионер | 2 - серия
16:04
Million Show
Рет қаралды 1,9 МЛН
Who's spending her birthday with Harley Quinn on halloween?#Harley Quinn #joker
01:00
Harley Quinn with the Joker
Рет қаралды 13 МЛН
How Many Batteries For a 3000W Inverter?
6:09
Cleversolarpower by Nick
Рет қаралды 1 МЛН
AMP HOURS EXPLAINED (amp hours vs watt hours)
10:59
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 993 М.
How Many Solar Panels To Run a Fridge/Freezer?
5:55
Cleversolarpower by Nick
Рет қаралды 865 М.
How Many Solar Panels to Charge a Battery?
7:16
Cleversolarpower by Nick
Рет қаралды 129 М.
SAVE Thousands - Build your own home solar battery backup!
21:17
Projects With Everyday Dave
Рет қаралды 655 М.
Why NOT to oversize your inverter!
22:44
Off Grid Basement
Рет қаралды 80 М.
How to Size a Solar Charge Controller
8:44
Cleversolarpower by Nick
Рет қаралды 111 М.
風船をキャッチしろ!🎈 Balloon catch Challenges
00:57
はじめしゃちょー(hajime)
Рет қаралды 21 МЛН