Clogged HVAC condensate drain line. Installing a Rectorseal Model SS2 overflow shut-off switch.

  Рет қаралды 43,712

Brantley Blended

Brantley Blended

Күн бұрын

We had a clogged HVAC condensate drain line. We heard the overflowing condensation dripping onto our main floor ceiling. I installed a Rectorseal Model SS2 condensate overflow shut-off switch.
Follow us on the socials.....
/ brantleyblended
/ brantleyblended
/ brantleyblended
I'm not asking, but if you feel like helping us with our projects and videos, it is always greatly appreciated.
Cash app $BrantleyBlended

Пікірлер: 62
@scottdevore5956
@scottdevore5956 Жыл бұрын
Am I the only one who screamed "Nooo!!!" at the computer screen when he said he was going to cut out the tab on the secondary outlet? Came here for the comments and didn't see any about it. Glad you left it alone. 😂
@BrantleyBlended
@BrantleyBlended Жыл бұрын
Haha! I almost cut it out but decided against it at the last minute.
@ronaldpalmer1241
@ronaldpalmer1241 Жыл бұрын
I wanted to scream too. Fortunately he figured it out logically. I was impressed with that.
@ShelleyVideo
@ShelleyVideo 11 ай бұрын
Yep......me too. If he had knocked out that little baffle/restrictor the safety switch would have prematurely broken the circuit.
@SocietalProblems
@SocietalProblems 5 ай бұрын
I started laughing my ass off when he said he was going to do that x'DDD
@MrTrevortf
@MrTrevortf Ай бұрын
I was like, no he's not gonna do that is he? Lol
@brainbronelamir8908
@brainbronelamir8908 Жыл бұрын
I liked the way you explain every single thing and the way you films and do the job , because I am immigrants to US and my English is not perfect,, But your way of explaining I'd excellent .. Thank you
@DarkJustice1999
@DarkJustice1999 Ай бұрын
I’m not an immigrant born in the United States and I still appreciate everything that he broke down in this video
@Ojeramup12
@Ojeramup12 3 ай бұрын
This is the only video that really show how to connect this SS2, thanks.
@carsandhealthtoddrosenzwei2661
@carsandhealthtoddrosenzwei2661 14 күн бұрын
Nice work. FYI. They also make 90° pvc Traps that have a removable clean out drain at the bottom of the trap instead
@michiganmike5761
@michiganmike5761 Жыл бұрын
Hope things are operating properly for you. Just came across your video and would suggest you replace your 90 degree elbow above the trap where the humidifier drain goes down to your a/c drain with a T-fitting and have an 8 inch stand pipe installed and left open so you allow air flow for the drain to run freely. If there is no air gap left then the water draining could and probably will always backup and continue giving you problems. With the open pipe you can always pour some white vinegar into the pipe to help keep the mold from building up. Take care.
@dorondavid8537
@dorondavid8537 Ай бұрын
Good job I am happy you uosed your common sense Good thing you didn't break the overflow
@ctorres441
@ctorres441 13 күн бұрын
Thanks for the video help to understand better the safety switch installation , you know, some others guys recommend don't apply glue on the switch in case you have problems for bad switch and is going to be a headache replaced , but your video still great and util
@mosdephh
@mosdephh Жыл бұрын
Excellent explanation! I've been curious for a while about how to wire one of these OF switches on my Goodman unit and now I know. Thank you!
@Pw6872
@Pw6872 7 ай бұрын
I think everyone will agree that having an access panel to the evaporator is a really nice feature. This should be standard on furnace/ac combos where oftentimes the only way to see/clean the ac evap is through a whole-house humidifier (remove filter) or to cut a hole in the ductwork. 😢
@drg424
@drg424 2 ай бұрын
Your right pw, it does your customer a good service. A clean well maintained unit last longer and consumes less energy.
@gmood1291
@gmood1291 2 жыл бұрын
You need a inlet that allows you to pour white vinegar into this drain line a couple of times a year. That will keep mold from building up in your lines. I also have a spray foamed home and live in Alabama. Had my issues with moisture. Installed a whole house dehumidifier about 7 years ago. It helps tremendously during the winter! I use my upstairs HVAC as a dehumidifier in the summer time. Since it's a 1.5 ton unit. I allow it to do most of the work during summer months. It keeps the house comfortable during the day. If the temp is set right on your upstairs unit. The dehumidifier will be unnecessary during the hotter months of the year. I also have those Goodman units. 😂 Definitely had problems over the years. Most HVAC professionals will tell you, they are fairly simple to replace parts on and overall cheaper to repair than the more complex systems.
@BrantleyBlended
@BrantleyBlended 2 жыл бұрын
Ive had my dehumidifier turned off for a few weeks this summer. With the air conditioner and and dehumidifier going, my house was actually getting too dry. That was causing us a few problems like dry skin and dry sinuses. I turned it back on about a week ago. We’ve had a lot of rain lately in Georgia so the humidity in the house was getting too high again.
@gmood1291
@gmood1291 2 жыл бұрын
@@BrantleyBlended What size tonnage are your HVAC units? I find during the shelf seasons of the year. That's fall to winter and spring to summer changeovers. I use the dehumidifier the most. Since those are the times when the AC cooling is unnecessary.
@DoeyPP
@DoeyPP 2 ай бұрын
That is your secondary drain ,which the plastic is part of the pan to put the water level higher which makes it the secondary
@williambee7368
@williambee7368 Жыл бұрын
GREAT Video. I'm also in Georgia and having Drain Line issues This Year. After viewing a few videos, I can share that Your Video is exactly what I needed to see. Thanks again for all that you do.
@SocietalProblems
@SocietalProblems 5 ай бұрын
You don't want to tighten it too much because it can cause the pan to crack. You should have kept the SS2 a little loose to the point where you can actually turn in slightly. The tape will make sure it doesn't leak. Plus if water does get into the switch; to avoid vacuuming it you can just twist is down and empty it. Certified
@karenkline7221
@karenkline7221 2 ай бұрын
BTW 78° isn't hot .. but, I'm sure it's hotter in the attic..
@RDDeadboy
@RDDeadboy 10 ай бұрын
I think my favorite idea from KZbin is put a cutoff valve above your u trap and install a Waterhose connector befor the u with a cutoff valve so you can just connect a water hose and send it
@Honestandtruth007
@Honestandtruth007 2 ай бұрын
The AC drain line SHOULD BE easy to Clean Out when Properly installed 👍😅. When NOT installed Correctly then it's a Mess 😕😔
@BeckVMH
@BeckVMH Ай бұрын
Haha KZbin certified. I had to have qualified a long time ago. I want my certificate!
@drg424
@drg424 2 ай бұрын
Also u must have enough fall to supercede the water column of the return . In layman terms the ahu has a negative pressure, if u have 2 inches of negative pressure w.c. u must have that much fall before the p trap. It's not all cut and dry .I've seen contractors make the same mistakes. If they only would not he proud and read the Manuel and code book they would be ahead of future problems. I'm not a Eisenstein, just a old mechanical contractor that god has lead through the years of a fantastic trade.
@kewlbud8868
@kewlbud8868 2 жыл бұрын
I don't know if it was said or now. But instead of taking anything apart, and you knew where the drain exited the house, You should of gone there, rapped a wet drag around the pipe to get max suction from your shop-vac, and sucked the clog out there. Heck of a lot faster, easier, and cleaner, since I bet you'll be doing this quite a bit until everything's tunes in.
@BeckVMH
@BeckVMH Ай бұрын
I’ve seen a number of videos explaining that process and is a recommended method.
@lillithjones993
@lillithjones993 Жыл бұрын
Thanks for your help!
@DoeyPP
@DoeyPP 2 ай бұрын
Do not knock that out you will be in trouble
@drg424
@drg424 2 ай бұрын
It's the 2ndary over flow drain , code requires. The secondary to run out over a widow to alert owner that main drain is clogged. A flag for the inspector. Better safe than sorry. Mechanical contractor since 1980. A proper drain means a lot u don't want the water to overflow into the ahu then to the emergency drain pan.u wNt the overflow to come out the factory secondary drain then to the em drain out out over window.
@joedixon8804
@joedixon8804 21 күн бұрын
Need to eliminate those unions. Come off the unit with a new p trap and clean out tee
@davidstevens1911
@davidstevens1911 5 ай бұрын
By putting the switch in the R wire you will kill both cooling and heating, In the heating mode you are not going condensate, but I can't tell you if there is a better place to put on a heat pump. I'd have to look at the wiring diagram to figure it out.
@Keith_Mikell
@Keith_Mikell Жыл бұрын
You had your tool up there. use tape and vacuum it out. No need for water unless youre cleaning the coil. LEAVE THAT THERE. It's the secondary hence why its blocked off a bit.
@anthonylong001
@anthonylong001 8 ай бұрын
If you remove that piece of plastic that shut off would constantly fill and your unit would not run
@DoeyPP
@DoeyPP 2 ай бұрын
Pulling air from above at the humidifier.
@bobbyprice2995
@bobbyprice2995 2 жыл бұрын
You know, I was gonna start this out by saying some derogatory comments regarding your meandering about spray foam. But, then I guess you're pretty smart for using the internet to fix your home on the cheap. Good job. I'm sure that you've convinced some manufacturers to hook you up or monetize this video. Btw, what is your average power bill? Did you G.C. your own home?
@BrantleyBlended
@BrantleyBlended 2 жыл бұрын
Power bill is $175 - $250 depending on time of year. I used a GC to build my house. I did some of the work myself. No manufacturers care about a tiny channel like mine. I pay for everything.
@jeffgriffin820
@jeffgriffin820 2 жыл бұрын
Another thing I forgot to say was i would go with closed cell foam instead of open cell. Open cell foam does not have a vapor barrier closed cell does
@darrylwashington840
@darrylwashington840 Жыл бұрын
Good job!
@thenexthobby
@thenexthobby Жыл бұрын
Interesting … you’d think (or, I’d think … ) a float switch would be part of the system already. I’m learning that’s not the case. My attic unit leaks, and the pan beneath it overflows. Now I’m considering a 2nd float switch, that kind you have in the line and and a pan switch at the bottom … because water coming downstairs is a really bad day. Maybe just wire the pan switch to an alarm that says, “Hey moron, turn off the A/C now!!”
@TheDigitaldoug
@TheDigitaldoug 2 ай бұрын
Is teflon tape really needed on plastic fittings?
@garybensel6680
@garybensel6680 25 күн бұрын
What a waste of time! Next time it plugs up just use a shop vac on the outside drain. This is a very common problem with mini splits. It’s a good idea to make this a spring cleaning chore every year. That overflow should be knocked out and the wires should go in between the red wire to the thermostat
@danielellis3217
@danielellis3217 2 жыл бұрын
Do you think you would've had all the ventilation issues with the spray foam if you only used foam in the attic and basement then used regular fiberglass insulation on ext walls?
@ChutneyInc.
@ChutneyInc. Жыл бұрын
went to my attic and i see bats
@FranciscoHernandez-gt8ne
@FranciscoHernandez-gt8ne 10 ай бұрын
Noooooo don’t knock off that eyebrow on inside the secondary !
@tcthetford
@tcthetford 2 жыл бұрын
Should be a running trap. Just call the installer boss and send him a bill of $8000.00 and he will fix the situation immediately.
@JC-rh5zi
@JC-rh5zi 11 ай бұрын
I want a filter door like he has can I get it aftermarket for a Goodman
@2bnax
@2bnax 2 ай бұрын
Did the compressor stop running when you lifted up the float?????
@BrantleyBlended
@BrantleyBlended 2 ай бұрын
Yes, the whole HVAC system shuts down
@SeahawkAz
@SeahawkAz Жыл бұрын
Why is there no condensate pump?
@ShelleyVideo
@ShelleyVideo 11 ай бұрын
Gravity does the work of draining the water from that attic location.
@danielgentry9257
@danielgentry9257 3 ай бұрын
Leave it in there
@funnykunai1
@funnykunai1 Ай бұрын
10:44
@jeffgriffin820
@jeffgriffin820 2 жыл бұрын
Do you have open or closed cell sprayfoam in your home? I seen your other video about your opinion on sprayfoam I disagree. Look up build tight ventilate right if you having problems with being uncomfortable in your home it should be the hvac guys fault for not ventilating your home properly
@BrantleyBlended
@BrantleyBlended 2 жыл бұрын
Open cell foam
@panoskatakouzinos2391
@panoskatakouzinos2391 Жыл бұрын
Dude. Leave you air handler alone and call a professional. You will be doing yourself a big favor.
@BrantleyBlended
@BrantleyBlended Жыл бұрын
A “professional” installed my hvac units and did a terrible job. I don’t think too highly of most “professionals”.
@ShelleyVideo
@ShelleyVideo 11 ай бұрын
The so called "pros" hate to see DIY homeowners keeping that money instead of putting it into their 'professional" pockets! That air handler belongs to you and you can do whatever you want with it!@@BrantleyBlended Very good video.
@ayo1480
@ayo1480 3 күн бұрын
Pretty sure it's harder to find an honest technician who's willing to diagnose/repair the unit
@2BEorNOT2B3
@2BEorNOT2B3 Жыл бұрын
Put bleach in the pipe monthly bud!
HVAC Condensation P Trap installation | Stops Leaks!
11:31
Kelly Concepts
Рет қаралды 23 М.
A Few Condensate Considerations
25:33
HVAC School
Рет қаралды 58 М.
Вы чего бл….🤣🤣🙏🏽🙏🏽🙏🏽
00:18
Challenge matching picture with Alfredo Larin family! 😁
00:21
BigSchool
Рет қаралды 40 МЛН
How To Install Water Safety Switches
28:39
Alex Z
Рет қаралды 2,8 М.
HVAC DIY Maintenance - Float Switch Explained
10:05
ArcLight Addicts
Рет қаралды 268 М.
AC Drain Clogged P Trap last place I looked
15:09
Anti DIY HVAC
Рет қаралды 54 М.
HVAC Contractors Hate Me For Sharing This Secret
10:21
The DIY HVAC Guy
Рет қаралды 886 М.
The best way to install a drain trap!
3:56
World of HVAC
Рет қаралды 46 М.
Condensate Line Installation - Alexander Services
10:11
Alexander Services
Рет қаралды 81 М.
I Made My AC Condensate Drain Much More Functional
14:35
Skill Savvy DIY
Рет қаралды 4,9 М.
Float Switch Installation
8:18
John Jennings
Рет қаралды 28 М.
EASIEST Way to CLEAR Your HVAC Drain!
6:03
HVAC Guide for Homeowners
Рет қаралды 83 М.
Wire Routing & Float Switch Positioning
6:14
HVAC School
Рет қаралды 20 М.