@n4thb4dc05 ай бұрын
Try telling BT, Open reach, Kelly communication, sky and Virgin Media about securing overhead cables properly, they just say "oh it's not carrying voltage" oh right so that's gonna save a life when it falls and someone gets caught and dies, it's ok because it's not a voltage carrying cable,
@peterhall95165 ай бұрын
Agreed, cowboy outfits masquerading as respectable organization's
@efixx5 ай бұрын
The information's here for them! 💪
@retrozmachine11895 ай бұрын
This is why I can occasionally be seen making comments about people doing data & electrical having had experience in the other profession too to do it properly. There's a lot of benefit in having walked on both sides of the fence, in my opinion.
@james.telfer5 ай бұрын
Had two young BT guys gaffer tape a new phone line to the front of a cupboard because they couldn't be arsed to move it away from the wall to drop it down the back, so that sounds normal.
@UKsystems5 ай бұрын
Generally, they will not install anything inside the building that canning tangle people anyway due to the way they install it
@gospelman72225 ай бұрын
This is personal to me. Alan Bannon, who perished in the Shirley Towers, Southampton, fire, was a work colleague for some years. Smashing fella to work with.
@RobertMcDonnell-yf7ll5 ай бұрын
Ex door entry installer , we started doing this about 2012, we used metal p clips inside trunking, the company that I worked for always took it seriously, a bit if extra work could ultimately save someone,
@restfulplace32734 ай бұрын
Solid content. Unexpected issue that needs to be more commonly understood
@efixx4 ай бұрын
Thanks very much! 😊
@anthonybragg5 ай бұрын
There must be thousands of blocks of flats where door-entry, TV systems in mini trunking, and new lighting in PVC conduit have been added over the years
@efixx5 ай бұрын
Yup, and this is a step along the road to fixing the problem. 💪
@james.telfer5 ай бұрын
Those trunking clips would also useful to stop being attached by the avalanche of random cables when you take the lid off... 😱
@tebscat5 ай бұрын
Good informative video. One of the better ones.👍
@efixx5 ай бұрын
Thanks very much. 😊
@andysims49065 ай бұрын
It’s very disheartening when you go to all this trouble to comply and the cctv or burglar alarm company come along and don’t give a toss. See it all the time
@efixx5 ай бұрын
Yup, but the more we spread the word and make our own work compliant the more likely they'll cotton on! 💪
@james.telfer5 ай бұрын
Security Installer here: It's in the NSI standards to comply and we've been doing it for years. Obviously there are one-man bands that probably aren't registered, so no one to police them.... Also, if under fit-out/contruction the site manager or PM should be asking how they're fixing as we normally request the sparkies do the basket/containment.
@TheChipmunk20085 ай бұрын
Report them
@UKsystems5 ай бұрын
You can always contact local building control because they’ve charged for work that is non-compliant and they will likely take some investigatory action
@neilrowlings5 ай бұрын
Great video. Could you maybe delve into the regulations regarding the routing of SWA submain distribution cables through a building & the avoidance of routing these through 'protected escape routes'? Would be interested to hear your thoughts.
@efixx5 ай бұрын
Good question. 👍
@neilrowlings5 ай бұрын
@@efixx Section 422 (422.2), Appendix 13 & May 2023 Corrigendum relate to this specifically. It is a tad confusing but after contacting the NICEIC, they clarify that sub-main/ distribution cables must not run through protected escape routes & the only permitted cct types are the 3no. in 422.2....wondering if you guys agree?
@efixx5 ай бұрын
@@neilrowlings Tune in to eFIXX TV next Wednesday we have Michael Peace from the IET joining us. Amd 4 may have some changes to this.
@neilrowlings5 ай бұрын
@@efixx great, what time?
@efixx5 ай бұрын
@@neilrowlings 8:00PM stream link will be up on Monday ready for the Wednesday show
@night44015 ай бұрын
This is amazing, just found your channel. I am hooked, subscribed and notifications ON! Let me know if you have any other content out there for additional support.
@effervescence56645 ай бұрын
In the last 12 months I've upset numerous commercial office refit companies because they've used plastic conduit and plastic saddles in the refits across the ceilings regardless of height. I insisted the saddles be replaced with metal and after some huffing they complied but surely companies doing this should keep up with amendments and technical bulletins. Or are these large companies just operating on the principle it's cheaper to pay the fine/ compensation etc than doing the install properly.
@truefoa5 ай бұрын
Excellent video
@efixx5 ай бұрын
Thank you kindly. 😊
@abc123evoturbobonkerАй бұрын
I'd love to use the Mashall Tufflex firefly clips.. sadly they only sell them by the 400 or so, totally crazy, such a shame.. cool products I cannot warrant using
@garethmatthews54885 ай бұрын
Considering an EICR would it be recommended to retro fit non combustible fixings ?
@ks-hg5vo5 ай бұрын
Just been given c2 on cables above false ceiling as they don't have metal clips installed prior 2000 tho so should be a c3???
@olly76736 ай бұрын
And exactly where is the link in the notes to the training package then Joe, eh, where??? 😆
@efixx5 ай бұрын
Here it is 😆👉 training.efixx.co.uk/course/compliant-containment-in-association-with-marshall-tufflex
@Ste20235 ай бұрын
Haha
@mikethemask15255 ай бұрын
So what about in a domestic house 🤔
@efixx5 ай бұрын
Same rules apply but most cables are above plasterboard which is a fire barrier for typically 30 minutes.
@mikethemask15255 ай бұрын
@@efixx ok but most fires will over 500c and 30mins most firefighters are just turning up at the scene these days 🤔
@efixx5 ай бұрын
Thats the requirements set in the building regulations. Thirty minutes should mean the property is empty and no need for a fire fighter to enter.
@JimWhitaker5 ай бұрын
Definition of "premature"?
@robertjones34775 ай бұрын
I hope all the Asian countries see this as what they use certainly wouldn't be compliant here in the UK 😂
@BobHannent5 ай бұрын
Best practice is no bad thing, but the electrical industry clearly keeps making changes to regulations to make work and require money spent on training. Hey, surprise, it's a sponsored video... The emotional plea at the beginning was really over the top.
@efixx5 ай бұрын
If the changes increase safety standards and prevent needless deaths then that's not a bad thing. I'd rather be a bit over the top when emphasising that people lost their lives because of poor electrical practice than make light of it and more people die.
@AAaa-wu3el4 ай бұрын
@@efixx A concrete house is much safer that build of wood. To prevent needles death every house should be build of concrete, isn't it.