Column chromatography

  Рет қаралды 9,135

Lab Life Tutorials

Lab Life Tutorials

Күн бұрын

In this video we explain and demonstrate how to set up a column for flash chromatography on silica, how to load the crude compound, and how to follow the separation of the product from the impurities.
Things to remember:
SAFETY:
1) Silica for column chromatography may cause irritation to the respiratory tract if inhaled. Handle it under a fume hood.
2) The organic solvents commonly used for column chromatography may be volatile and flammable. If that is the case, handle them under the fume hood and take all the necessary precautions.
GOLDEN RULE OF FLASH CHROMATOGRAPHY: never trash any fraction before you are 100% sure you have successfully isolated and collected your product.

Пікірлер: 19
@GodlikeIridium
@GodlikeIridium 7 ай бұрын
Very good tutorial! It's very important to always add the silica gel as a slurry, never dry as some do. Besides that, all surfaces must remain as straight as possible. The sample loading by first adsorbing it onto some silica gel instead of applying it in solution is very interesting, i've never seen that technique! But I guess it's only really needed if the product isn't soluble enough in the eluent to apply with a small volume. Thanks a lot for that! I've got just a few additions: - Better put safety clips on every joint while evaporaring. Losing your product in the rotavap water sucks^^ - Stopper instead of aluminium foil - use those manual pump balloons if you need pressure. Using nitrogen to pressurize the system is always a safety risk. And put a safety clip between the column and reservoir. I've had a liter of solvent splashed into my face because a colleague overpressurized the column. Luckily not really dangerous solvents. With acidic or basic ones I may be blind now. - don't spot on the outer sides of TLC plates. They usually don't flow perfectly straight on the side.
@user-ou9tq4dc3i
@user-ou9tq4dc3i 3 ай бұрын
why is that better to add the silica gel as a slurry and not dry and pack it with solvent after?
@ghislainenz3257
@ghislainenz3257 3 жыл бұрын
thank you so much!!!
@salehchem4376
@salehchem4376 Жыл бұрын
Thank you so much. Is there standard to use silica gel in column, I mean if my sample a little bit like (0.01 gram), how much of silica gel use here? in contrast, if I have a lot of samples such as (1 gram or more), here, how much of silica gel have to use? I mean is there ratio from silica gel to sample to use in column, please tell me
@GodlikeIridium
@GodlikeIridium 7 ай бұрын
Yes. He showed a little chart. Depending on the different RF factors determined by running a TLC on a silica plate with the same eluent, you'll need about 20 to 100 times more silica gel than product to separate. That chart is a retty good rule of thumb. The RF factor also lets you estimate the total volume of eluent you'll need etc. So it's always better to first find a suitable eluent (and maybe stationary phase. Usually we always use silica gel. But there's also reverse phase silica with C18 chains bonded to it (reversing the whole polarity. So you use more polar solvent for retardation and more organic will elute faster).
@salehchem4376
@salehchem4376 Жыл бұрын
happy new year. If I have solid sample containing components, can I use any solvent to dissolve it? Or I have to use only the same mobile phase as solvent to dissolved sample? Another case, if must use same mobile phase, but my sample can not dissolve, here, please I need solution to this problem. can I use any solvent? thank you alot
@GodlikeIridium
@GodlikeIridium 7 ай бұрын
No. Because if you use a different solvent than your eluent, this will drastically change and disturb your separation. But he showed a great way to circumvent that problem by suspending it in silica gel, evaporating the solvent off, thus depositing it on the silica gel and loading it onto the column that way! Never seen this before, but it's pretty smart! Btw you'll have the same problem in HPLC. You can't run a reverse phase HPLC with a highly aqueous mobile phase but dissolve your samples in THF. This will tear your peaks apart, since it elutes much faster with that bit of THF (opposite for normal phase). Absolutely destroys the efficiency of the separation.
@LithiumSodium
@LithiumSodium 2 жыл бұрын
Stupid question: what is the reason of putting a layer of sand on top of the frit at the bottom of the column?
@pierangelogobbo6786
@pierangelogobbo6786 2 жыл бұрын
It's not a must, but I prefer having it to avoid clogging the frit. It also makes it easy to empty the column at the end.
@salehchem4376
@salehchem4376 Жыл бұрын
If I used wet packing of silica gel to column (slurry), here, can I use any solvent for silica gel until reached slurried, or must use only hexane. thank you
@GodlikeIridium
@GodlikeIridium 7 ай бұрын
Yes, you can use any solvent. It must be your eluent though.
@salehchem4376
@salehchem4376 7 ай бұрын
thank you@@GodlikeIridium
@benjaminmugala1920
@benjaminmugala1920 Жыл бұрын
Can this technique be used to separate proteins in blood?
@GodlikeIridium
@GodlikeIridium 7 ай бұрын
Theoretically yes, practically, no (as far as I know at least). But for protein separation I'd probably rather use an HPLC and size exclusion columns, if available of course. It of course depends on the properties of the proteins to separate, but usually it's best to separate them by size exclusion HPLC based on their molecular mass.
@eliasabdelnour7660
@eliasabdelnour7660 2 жыл бұрын
Why are you putting the last layer of sand before putting the crude mixture ? thank you
@jhyland87
@jhyland87 Жыл бұрын
I believe that's just to kinda hold down and stabilize the top layer of silica. You don't want it moving at all when you pour the eluant onto it.
@GodlikeIridium
@GodlikeIridium 7 ай бұрын
Exactly, to keep the layer horizontal. Any disturbance in the layer of silica gel will decrease the efficiency of the column, because different heights of silica will cause different separation on each vertical column of your column. Sand is heavy and has much less surface area than silica gel.
@smritirana7719
@smritirana7719 Жыл бұрын
Can i use cotton instead of sand
@GodlikeIridium
@GodlikeIridium 7 ай бұрын
Sure, but this will decrease the efficiency (in plate numbers) of your column, because sand gives a better straight layer to hold the silica. But you can keep that at a minimum by only pluggging the narrow end of the fritless column with cotton. If you've got a column with a frit anyways, sand isn't needed. Though it's always good practice to put sand on top of the silica, to protect the silica layer from being disturbed. TL:DR any disturbance of the flatness of your silica layer will decrease the efficiency. Knowing and watching that, you can do a column however you prefer.
Chemical/Laboratory Techniques: Column Chromatography
13:36
University of Groningen
Рет қаралды 3,9 М.
The child was abused by the clown#Short #Officer Rabbit #angel
00:55
兔子警官
Рет қаралды 25 МЛН
你们会选择哪一辆呢#short #angel #clown
00:20
Super Beauty team
Рет қаралды 50 МЛН
Alat Seru Penolong untuk Mimpi Indah Bayi!
00:31
Let's GLOW! Indonesian
Рет қаралды 16 МЛН
Дарю Самокат Скейтеру !
00:42
Vlad Samokatchik
Рет қаралды 3,3 МЛН
Carbon Capture Technology Explained | Seachange
5:24
Freethink
Рет қаралды 351 М.
How to Pack a Column (for Column Chromatography)
10:30
ThePenguinProf
Рет қаралды 64 М.
TLC-The Basics | MIT Digital Lab Techniques Manual
16:03
MIT OpenCourseWare
Рет қаралды 169 М.
Column Chromatography
27:16
Channel One
Рет қаралды 122 М.
Column Chromatography
11:48
Professor Dave Explains
Рет қаралды 246 М.
HPLC  | High Performance Liquid Chromatography | Application of HPLC
11:12
Animated biology With arpan
Рет қаралды 164 М.
【4K】-- Column Chromatography (Purification)🌟
18:42
Chem Leggo
Рет қаралды 126 М.
Tretyakova Lab • Silica Column Prep
10:53
Natalia Tretyakova
Рет қаралды 3,4 М.
Rotary Evaporator - Keep Dry-Load Samples in Place
1:14
Teledyne ISCO
Рет қаралды 1,3 М.
Первый обзор Galaxy Z Fold 6
12:23
Rozetked
Рет қаралды 401 М.
تجربة أغرب توصيلة شحن ضد القطع تماما
0:56
صدام العزي
Рет қаралды 36 МЛН
Мой инст: denkiselef. Как забрать телефон через экран.
0:54
Красиво, но телефон жаль
0:32
Бесполезные Новости
Рет қаралды 509 М.
1$ vs 500$ ВИРТУАЛЬНАЯ РЕАЛЬНОСТЬ !
23:20
GoldenBurst
Рет қаралды 1,6 МЛН