You are so calm. You speek to the point..no unnecessary talk. Covering all the points while teaching main point. 😊 Thank you so much for sucha an informative content🙏
@electricalautomation9 ай бұрын
Appreciate your comments. Yes, I tried to show all the procedures in the video for the operation. That caused my videos most of them were around 30mins. But all of them include my understanding and detailed explanation. Thanks again!
@libanabu62223 жыл бұрын
Awesome had some issue getting it done but watching your video over and over again like 300 times I was able to get it done. Big Thanks
@electricalautomation3 жыл бұрын
I super glad the video could provide some help. Those video are slight long and boring. But it includes many info and configuration steps, because my aim is that using those videos as my knowledge or experience summary. That also allows me to quickly warm up this tech if I left it couples of months or years. Again Welcome!
@Aman-et7hr2 жыл бұрын
Very informative video. No hidden tricks! Thank you so much sir!
@electricalautomation2 жыл бұрын
Glad you like it! Welcome! Yes, there is no hidden tricks in all my videos. It is my driven to deliver the 'solution' that if you follow the video step by step, then you will be also Win. That is also the reason my video usually >= 20mins, it looks too long but includes all the related info for the topic. Enjoy!
@sergeykiparenko11954 жыл бұрын
This video is big tressure. Thank you!
@electricalautomation4 жыл бұрын
Thank you, I am glad you like it!
@electricalautomation4 жыл бұрын
Recommend to use the latest CPU firmware to do the test. Some wired problem may be caused by the firmware issue. e.g. V4.4.1 of S7-1200 fixed some issues on the OPC UA functions. e.g. Update V4.4.1 The S7-1200 CPU firmware update V4.4.1 replaces the V4.4.0 and corrects the following issues: -Corrects the number of allowed S7 routed connections with left-side modules -When TIA downloads only hardware configuration, the OPC UA security policies are applied appropriately -Corrects the OPC UA Structure sizes in OPC UA Binary Protocol -Improves secure open user communication robustness -Allows secure open user communication when using self-signed certificates -Fixes sporadic DataLog corruption when downloading from the Web server
@jankleisnielsen36702 жыл бұрын
Great walkthrough, thanks!
@electricalautomation2 жыл бұрын
Glad you enjoyed it!
@wick_bourne Жыл бұрын
Hi! Beautifully explained. couldn't have been better. Three request: 1)Could you also do the same with simulated PLC (Siemens plc advanced v2.0). 2)Can same thing also be achieved with nettoplcsim? 3)How to the repeat the process with ABB PLC?
@MatheusHeitorSilvaFerreira3 жыл бұрын
Great video about OPC UA. I have a problem with Siemens OPC UA: currently using S7-1200 with firmware V4.4.1 and trying to transfer an array with 100 elements to my supervisory software. But S7-1200 doesn't allow transfer entire array, only individual elements with individual NodeIDs. But with that many array elements the acquisition time goes beyond 800 ms and I need it to be under 100 ms. Do you have an workaround in how to send an entire array data through OPC UA?
@electricalautomation3 жыл бұрын
You may program a FB for copying DB1 to DB2. DB1 is the data within a arrary, DB2 is the data under a "STRUCT". DB2 is used for OPC UA interface. You have to program by yourself to do 'copy'. You can refer the link support.industry.siemens.com/cs/document/42603881/how-do-you-copy-memory-areas-and-structured-data-in-step-7-(tia-portal)-?dti=0&lc=en-WW
@NasirMehmood-yt7nw Жыл бұрын
Thanks dear very help full knowledge
@electricalautomation Жыл бұрын
Welcome! This is very early OPC UA video, I also have some updated OPC UA videos in my channel, please search and enjoy
@ThotaNagasudheer3 жыл бұрын
Very thankful for the information..👍
@electricalautomation3 жыл бұрын
Thanks for watching! Welcome!
@williamli3788Ай бұрын
thanks , can you give me some advise for how to install different version Tia in one PC
@electricalautomationАй бұрын
You can install multiple versions of TIA in one PC, I would recommend install them following from low to high V16->V17->V18..
@williamli3788Ай бұрын
hi, when i follow your steps to install Tia, i get the error as followed: TiA Portal V17 WinCC Prof Ed cannot be operated in parallel with the currently installed version of WinCC Professional'or WinCC Runtime Professional. Please remove WinCC Professional'and WinCC Runtime Professional in order to operate TA Portal V17 WinCC Prof Ed. If you uninstall WinCC Professional'via Control Panel,select 'Siemens Totally Integrated Automation Portal'and follow the wizard.
@logandematteis69752 жыл бұрын
is there a way to set a custom nodeid ? because I have to set them at a specific identifier to use them on another program (and I can't set them as string because I use S71200 and it's not supported)
@electricalautomation2 жыл бұрын
Sorry I have no idea, probably search some documents for OPC UA standard and protocol.
@oogalook3 жыл бұрын
Great guide, thanks very much!
@electricalautomation3 жыл бұрын
Glad it would be helpful! Thanks for watching, welcome!
@ishouldbeonmountrushmore81562 жыл бұрын
thanks for your effort
@electricalautomation2 жыл бұрын
Our pleasure! Welcome!
@nickiho39973 жыл бұрын
Hi, could you show how the Sign&Encrypt and User administration be handled both on the PLC and the client side PC? Since if this is really deploy for a customer, they always want the full armor security, and ideally want an OPC-UA XML file exported for them for customer integration. Thanks!
@electricalautomation3 жыл бұрын
Would be my plan for the OPC UA security just not recently, I am working on motion control videos these days. Did you have troubles on the OPC UA with encrypt setting? I'd like to know which specific step you got trouble.
@haonguyenquang2423 жыл бұрын
Thanks, very detailed.
@electricalautomation3 жыл бұрын
Glad it was helpful!
@electricalautomation4 жыл бұрын
S7-1500(OPC UA Client) -> COM09. OPC UA - Siemens S7-1500(OPC UA Client) and S7-1200(OPC UA Server) TIA Portal kzbin.info/www/bejne/pXTLh5aIlrqnb68
@alexvan69214 жыл бұрын
hi for the 'simatic opc ua s7-1200 basic runtime license', is that required to purchase separately? my TIA didn't show up that option.
@electricalautomation4 жыл бұрын
Purchase or not doen't cause trouble on your OPC UA functionalities test purpose. Officially, you need to purchase the OPC UA runtime license. Regarding your question on not showing up, please check out if you are selecting S7-1200 with version V4.4., and the TIA portal V16. kzbin.info/www/bejne/b5Taq4mrZ6iZq6s
@jorgevarona29574 жыл бұрын
Do you know how to write th value of a node to an other node in UAexpert?
@electricalautomation4 жыл бұрын
Likely there is no way to write a node to another node in UAexpert. But an alternative way is that you could create two tags in OPC UA Server side (PLC), and let the PLC to copy or exchange between two tags. Or use KepserverEX software. KepserverEX has 'advanced tag' function, which allow you to copy from one tag to the other. You could see this 'advanced tag' function from kzbin.info/www/bejne/pnPLlJywpJqUj6s
@jorgevarona29574 жыл бұрын
@@electricalautomation I 'm gonna try it, thanks
@MrPrateek97112 жыл бұрын
Thanks for a descriptive video but when I tried these steps my UAexpert could not connect to OPC UA server and gave "failed due to badtimeout" error. Anyone faced the same?
@electricalautomation2 жыл бұрын
Does your OPC UA Client and OPC UA Server in a PC together or separately at different PCs.
@HermanWillems4 жыл бұрын
I wanted to use the OPC UA server functionality. I wanted to test it. But you need an aditional license for the OPC UA server to work. WTF Siemens. :( i just wanna play around. Also does Siemens Provide OPC UA with TSN? (Time Sensitive Networking?) for hard real-time data transfer? (Like Profinet, ethercat can) Im afraid they just do the LEAST effort for OPC UA. Unlike other PLC brands. :( too bad.
@Skookumshroom4 жыл бұрын
I just watched this, and enjoyed the experience second hand. My TIA is still V14 and the boss needed me to have this capability for a project last week. HMS Flexy 205 was a good choice. until I get V16. S7-1200 starterbox confirmed comes with a single OPC UA Server license, if this helps you. I have not asked for a price of a single license yet. namaste
@HermanWillems4 жыл бұрын
@@Skookumshroom ah yes. Its ok if the company pays the hardware and licenses. We already have Tia V16. We get the latest when its out. But im not gonna buy myself a license privatly with my own money. :) just looking for cheap IO nodes that have OPC UA... i dont mind the brand. Thought the S7-1200 series was a cheap option because i have a defect s7-1200 laying around.
@rahulravi44243 жыл бұрын
I get BadTimeout and Bad_SecurityPolicyRejected when i try to connect in Uaexpert... please help me
@electricalautomation3 жыл бұрын
Try without the security at first. And if no security can make, then check out the security setting in the PLC CPU OPC UA setting. Also turn off the windows firewall and virus software.
@rahulravi44243 жыл бұрын
@@electricalautomation Thank you for your reply ..the problem was in the PLCSIM advanced.. You are so helpful...Thank you bro
@electricalautomation3 жыл бұрын
@@rahulravi4424 Thanks Bro. According to the manual of the PLCSim Advanced, to test OPC UA, we have to select 'No Security'.
@MMKurdia3 жыл бұрын
Thanks a lot for this great video, what is your Linkedin account ?
@electricalautomation3 жыл бұрын
Hello, we can contact via email electricalautomation.handson@gmail.com. Thanks for watching!
@electricalautomation4 жыл бұрын
"PID11. OPC UA - Connect PLC (PID Controller) to Matlab/Simulink (Process Model) via OPC UA" kzbin.info/www/bejne/rH_TqpVmjsyHers
@pranavthakkar66874 жыл бұрын
Is it not same as kepserver? Just wanted to know more about this.
@electricalautomation4 жыл бұрын
When a software is needed to communicate with a PLC, the Kepserver is a common used tool to build up a bridge communicate with PLC and tranfer the data to the third end software. But OPC UA open a new door, if the software support OPC UA (OPC UA would be more common protocol on the communication ), the PLC which is built in OPC UA protocol can exchange the data with the third end software directly. The OPC UA also allows the PLCs or controllers comes from different brands can exchange the data directly without relying on another software. The machine-to-machine communication can be realized.
@electricalautomation4 жыл бұрын
Take Omron NX102 and Siemens S7-1500 controller as example, they both support OPC UA. The S7-1500 can run as OPC UA Client, while NX102 runs as OPC UA Server, then they can communicate together.
@pranavthakkar66874 жыл бұрын
@@electricalautomation so what do you think about the 3rd party softwares which are still used to get the data!! Will it becomes vanish?
@sergiopat914 жыл бұрын
@@electricalautomation ... The S7-1500 can run as OPC UA Client . How would I do that?
@electricalautomation4 жыл бұрын
@@sergiopat91 I will do a video S7-1500 running as OPC UA Client soon
@ashiqmumtaz87264 жыл бұрын
How to access the data logs via OPC UA?
@electricalautomation4 жыл бұрын
You could use the programming to exchange your data block DB using for data logs with the DB for OPC UA as 22:55. Use SCL ''FOR" loop will be easy to batch copy or shift the data in the Data block
@ikkusoft4 жыл бұрын
Thank you....great video.
@electricalautomation4 жыл бұрын
Thanks for watching!
@industrialautomationkotttu88413 жыл бұрын
wonderful explanation. Keep going.
@electricalautomation3 жыл бұрын
Thanks for your watching! Please review more videos on OPC UA topics. kzbin.info/aero/PL762SfoJC-e8Ng4OlME8WfQxf9qBhNTJh
@anshumansingh48343 жыл бұрын
Can we perform this in Plc sim
@electricalautomation3 жыл бұрын
No Sorry. You can use "PLCSim Advance" to simulate S7-1500 and test OPC UA. But PLCSim so far can not do OPC UA.
@industrialautomationkotttu88413 жыл бұрын
great
@electricalautomation3 жыл бұрын
Thanks!
@Dardjiskien4 жыл бұрын
Thanks very much
@electricalautomation4 жыл бұрын
Thanks for your watching! Welcome my channel!
@rafimarsidek35684 жыл бұрын
thank you sensei!
@electricalautomation4 жыл бұрын
Thanks for watching, there are some other videos about OPC UA topics in the play list: kzbin.info/aero/PL762SfoJC-e8Ng4OlME8WfQxf9qBhNTJh
@ludeknekuda99594 жыл бұрын
Thank you
@electricalautomation4 жыл бұрын
Thanks for your watching!
@derina.maleek94084 жыл бұрын
Thanks
@ShiqunQiguan3 жыл бұрын
Hi I'm using Raspberry Pi as a OPCUA Server, I have programmed the PLC control logic and cofigurated the variables supporting OPCUA features in CODESYS. However wenn I connect the OPCUA Client in UaExpert, I get following errors. The server returned no certificate, all certificate checks will be skipped. [uastack] OpcUa_P_RawSocket_InetAddr: getaddrinfo failed with 11001. [uastack] OpcUa_P_ParseUrl: OpcUa_P_RawSocket_InetAddr reports error 0xA0060000. Error ‘BadHostUnknown’ was returned during OpenSecureChannel. Please help me out! Thank you 请问你会说汉语吗?我们也可以用汉语交流,我在德国读书,寻求你的帮助,这个问题对我很重要,如果能解决,我很感激。先谢谢
@electricalautomation3 жыл бұрын
Sorry, I cannot answer your question since I never did Raspberry Pi. Probably you could try "None security". If you used UaExpert as OPCUA Client and it cannot read your Raspberry Pi OPCUA Server, most likely the OPC UA library used in your Raspberry Pi has issues.