No video

Conext MPPT 60 150 - Product Knowledge Series Part 2 - Menu Structure

  Рет қаралды 45,553

Schneider Electric Solar

Schneider Electric Solar

Күн бұрын

In this video, Eric reviews the menu structure of the Conext MPPT 60 150. The Conext MPPT 60 150 charge controller tracks the maximum power point of a PV array to deliver the maximum available current for the charging batteries. For more information, please visit solar.schneide.... #Solar #SolarEnergy, #OffGrid #LifeIsOn
Warnings and Safety Notice
Schneider Electric cautions you that electrical equipment should be installed, serviced or maintained ONLY by qualified electrical personnel. Remember that all sources of electrical power must be disconnected prior to visual inspection, tests, maintenance or installation of any electrical equipment. Failure to do so can result in serious personal injury, property damage, OR death.

Пікірлер: 43
@ivanostos
@ivanostos 4 жыл бұрын
Hi, could I use the Conext MPPT 60 150 controller to charge Victron Lithium LIFEPO4 12V 200AH? Thanks
@abojoud7405
@abojoud7405 Ай бұрын
Hello FOA,, thanks After I bought this controller, but still not install it, because I'm confusing how it will fully charge the battery and I have load all the time? I think it will keep be keep in high volt of bulk charging, And this will damage the battery storage, So, please advise what is solution Thanks
@thefilmfansclub
@thefilmfansclub 4 жыл бұрын
Hi, i have changed the battery voltage from 24v to 12v and the controller screen just turn off and it wont come back
@neomatrix2722
@neomatrix2722 Жыл бұрын
Hi @24v, what is the MAX watts in solar i can add to this charge controller plz. I read 2.5 tare (what ever that means) im guessing that is the max 2500 watts per charge controller?
@MrWei-nd7hj
@MrWei-nd7hj 5 жыл бұрын
Hi! I bought one of these for my Lithium Batteries but there is no custom settings. Hiw do I configure it? Thanks!
@raghavshankara5601
@raghavshankara5601 2 жыл бұрын
Why some of the menus not available in my system??
@RonMDavis
@RonMDavis 2 жыл бұрын
My unit is on a 48v pack that is 14s Lithium Polymer packs with custom battery menu setup for 57 v top out... however on occasion it will spike output as high as 62v which throws my inverter into a tizzy as its got an over voltage cutoff of 60v. How does one prevent the random overvoltage situation when we have great sunshine on our input PV array? Also I know there is a new firmware avail as my unit is older. How does on. Update that?
@SESolar
@SESolar 2 жыл бұрын
Hi Ron, Thanks for reaching out! Regarding your first question, please follow the link & submit this form (solar.se.com/us/en/support/#technical-support) so that our tech support agents could assist you. Technical support can also be reached via telephone, at 1-833-391-8640, 8am - 11pm, Monday - Friday (Eastern time). For the latest downloadable firmware, please go to solar.se.com/us/en/product/conext-mppt-60-150-solar-pv-charge-controller-2/#downloads and scroll down to "firmware."
@tobyjohnson6714
@tobyjohnson6714 6 жыл бұрын
Is this charge controller capable of charging a lithium ion battery bank?
@Bacardibombillo
@Bacardibombillo 6 жыл бұрын
All mppt commands will be overide with conext SCP..? Or mppt still has few features separately?
@ericbentsen1597
@ericbentsen1597 6 жыл бұрын
Great question. Any settings changes made on the MPPT60 will transfer to SCP and vice versa.
@earthenergyhex
@earthenergyhex 2 жыл бұрын
I have a ground fault code that cant be cleared. Did I fry my MPPT?
@SESolar
@SESolar 2 жыл бұрын
Hi Tony, We're sorry to hear about your error message; our tech support is available to assist you over phone or email. If you prefer phone support: *USA: 1-833-391-8640, 8am - 11pm, Monday - Friday (Eastern time) *Spain: 00-800-000-200-20, 8 am - 5 pm, Monday - Friday (Madrid/Paris time) Please visit solar.se.com/us/en/support/#technical-support) to find other countries' phone numbers, or if you prefer email support.
@bschena
@bschena Жыл бұрын
anyone know how to reset the Ground Fault error on these MPPT60 controllers? I've got 3 controllers that all show the same fault. this is the 3rd time it has happened in 6 months or so. I'm having the techs come out to try to figure out what's going on, but I'd like to get my (off grid) house back running temporarily if I can figure out how to reset the fault(s).
@SESolar
@SESolar Жыл бұрын
Hi @bschena, sorry to hear about your system. With multiple MPPT60 units, only one ground fault fuse should be installed in one MPPT 60. If that fuse has blown, it will need to be replaced by a qualified person. Thank you.
@thadhorner5129
@thadhorner5129 4 жыл бұрын
I am a solar installer, but I've never installed any Xantrex products, I usually just install Outback, but I just bought a Conext MPPT 60 150, and I'm trying to configure it before installing in the customer's system, but it only shows the History, Battery, and Display menus. The other menus are all missing! I think those are known as the Advanced menus. Outback has a password to get in to those settings. What password or button settings do I need to get into the Advanced menus for a Conext MPPT?
@thadhorner5129
@thadhorner5129 4 жыл бұрын
Nemmind, I found the answer. Basic/Advanced menu viewing is configured in the Display Menu.
@thadhorner5129
@thadhorner5129 4 жыл бұрын
@@SESolar I installed it, entered the settings I needed, and it works fine, but I did have one problem installing it - the knockouts on the bottom did not pop out like normal knockouts are supposed to do. Instead, they appeared to be insufficiently stamped, so they were stuck in place and I had to use a knockout punch tool to make the holes I needed.
@Tro1086
@Tro1086 3 жыл бұрын
@@thadhorner5129 Thanks for replying to your own post! I was looking for this info also! Iv installed a few Schneider systems, Inverter/MPPT/SCP, and usually configure everything on the SCP. Today I hooked up an MPPT to a battery by itself to get it charged and ready to install in the system, still putting the rest system together, but wanted to get the batteries charging while I was working on other stuff. I was confused by the EXTREMELY basic menus on the MPPT, and was thinking that it really sucks you have to have a complete Schneider system (Inverter/SCP) to actually fully configure an MPPT controller!!! The default AGM settings work pretty good for Lithium thou, probably not ideal, but works. Next time I mess with one, without the SCP, I will have to remember to switch to the advanced menu, the basic menu lets you change just about... nothing. I know on the SCP you can press ENTER/UP/DOWN, all together for about 3 seconds, and an "advanced settings" menu will be added to the display, kind of an "installers secret menu" I have felt your pain with the knockouts on these things thou, It seems like there was a batch with very poor knockouts, you had to try to punch them out from INSIDE the unit, instead of from the outside, which is pretty difficult since they are tucked way in the back, and they are so GENEROUS (NOOOOTTTTT!!!!) with wiring room inside these units. Besides being pre punched the wrong way, they were punched very poorly and were very hard to knock out. The last couple MPPTs Ive installed, it seems they have fixed this issue, and are easy to knock out, like they should be. (I love Schneiders equipment and systems, but I REALLY hate wiring them up! Cant they give us a little more room!)
@zulmavelazquez8858
@zulmavelazquez8858 4 жыл бұрын
Hi, I have been using this mppt contoller for 1 yr and 1/2 but know in the today's screen it shows 0.0 Ah and 0.0 kwh and in the Output screens is showing the amount of V and nothing else. But it is charging the battery bank. What would be the problem?
@zulmavelazquez8858
@zulmavelazquez8858 4 жыл бұрын
@@SESolar Hi, I submitted the forn already, thanks
@americanfreedom1777
@americanfreedom1777 9 ай бұрын
Any upgrade for lipo4 battery?
@babasolar7100
@babasolar7100 6 жыл бұрын
Plz full detail of charge controller
@uncontrollabledogs3791
@uncontrollabledogs3791 4 жыл бұрын
Not too helpful. Was looking to test logs to match my kwh meter.
@offgridlivingstlucia8865
@offgridlivingstlucia8865 6 жыл бұрын
Hi is that charge controller can charge 2 battery bank with deferent absorb an float
@ericbentsen1597
@ericbentsen1597 6 жыл бұрын
Hi Off Grid in St Lucia, the MPPT60 has a single input for battery connection, therefore it can only charge 1 battery bank. Multiple controllers would be needed to charge separate battery banks (at least 1 for 1). That said, you can have multiple controllers on a common battery bank provided the bank is sized to accept total current. That would be according to battery specs.
@offgridlivingstlucia8865
@offgridlivingstlucia8865 6 жыл бұрын
Thank you sir for replaying back
@babasolar7100
@babasolar7100 6 жыл бұрын
How much price of this product
@khyatisaini231
@khyatisaini231 Жыл бұрын
What does time online means?😢
@NaughtyGoatFarm
@NaughtyGoatFarm 3 жыл бұрын
Can these be used for Lifepo4 batteries? I assume that I would need to use the custom battery settings to set the charger voltage correctly for Lifepo4 chemistry?
@SESolar
@SESolar 3 жыл бұрын
Our products are compatible with multiple battery technologies, including Discover's LiFePO4 lithium batteries. For more detail about how to set up, please contact technical support at solar.schneider-electric.com/netsuite/
@NaughtyGoatFarm
@NaughtyGoatFarm 2 жыл бұрын
@johnny5finger thank you for your reply. I would be very interested to hear how this goes for you. I am a bit confused about the last sentence of your reply. Can you please confirm this. Are you changing it from 14.6 to 14.4 or is this a 2 voltage setting?
@earthenergyhex
@earthenergyhex 2 жыл бұрын
what does restart pending mean?
@SESolar
@SESolar 2 жыл бұрын
Hi Tony, This means that the solar charge controller is ready to restart but waiting for the timeout period to expire. This condition is normally only observed at dusk and dawn. You can find more information in the product's manual here: solar.se.com/us/wp-content/uploads/sites/7/2021/10/Conext-MPPT-60-150-Installation-and-Owners-Guide_975-0400-01-01_ENG.pdf Hope this helps!
@mackendyoscar5651
@mackendyoscar5651 7 ай бұрын
Reset
@concurseirooficial2797
@concurseirooficial2797 3 жыл бұрын
Como alterar a linguagem para português ??
@davidperez4681
@davidperez4681 Жыл бұрын
En español por favor
@pierrewilbertcadet5888
@pierrewilbertcadet5888 Жыл бұрын
Français
@miajardines1282
@miajardines1282 3 ай бұрын
no pongan el titulo en español si van hablar en ingles 🙄🙄🙄🙄👎👎👎👎👎👎
@abojoud7405
@abojoud7405 Ай бұрын
Hello FOA,, thanks After I bought this controller, but still not install it, because I'm confusing how it will fully charge the battery and I have load all the time? I think it will keep be keep in high volt of bulk charging, And this will damage the battery storage, So, please advise what is solution Thanks
Top 10 Beginner Mistakes When Building a DIY Solar System
17:39
DIY Solar Power with Will Prowse
Рет қаралды 1 МЛН
#3 SW4048 settings Schneider
16:30
CBI Solar
Рет қаралды 20 М.
Look at two different videos 😁 @karina-kola
00:11
Andrey Grechka
Рет қаралды 14 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 14 МЛН
Harley Quinn lost the Joker forever!!!#Harley Quinn #joker
00:19
Harley Quinn with the Joker
Рет қаралды 28 МЛН
Conext MPPT 60 150 - Product Knowledge Series Part 1 - Unboxing
1:34
Schneider Electric Solar
Рет қаралды 24 М.
Wiring the altE solar 6.8kW Battery backup kit (Part 2 of 3)
13:41
July 5, 2021
22:42
Carlos Rivera SOLARPR
Рет қаралды 7 М.
The TRUTH About OFF-GRID Solar | Winter Update
15:02
Ambition Strikes
Рет қаралды 528 М.
Wiring a Schneider XW Pro
10:24
Ben's Solar and Battery
Рет қаралды 12 М.
Best 5 Home Batteries Compared - BRUTAL OPINION! 🫢
1:01:05
Artisan Electrics
Рет қаралды 62 М.
Difference Between Grid-Tied, Off-Grid, and Hybrid AC and DC Coupled Solar Systems
7:08
Look at two different videos 😁 @karina-kola
00:11
Andrey Grechka
Рет қаралды 14 МЛН