Thank you for content, it helps my career path a lot
@AMJEngineering2 жыл бұрын
Thanks for feedback
@zemesguerra4 ай бұрын
Thanks for the vids. However, where and how did you get the CLTD correction for latitude and months?
@Dexter-v2j3 ай бұрын
Thanks for sharing your knowledge. It was well discussed and easy to understand. Can you please share the CLTDs for different latitudes? Thank you.
@Engr.Ruuveinzei Жыл бұрын
Hi, I hope you can read this. But how did you get a 21deg F from given 11.8 Deg C. Because if you are going to convert 11.8deg C it should be 53.24deg F.
@beardedpinoy8645 Жыл бұрын
good calculation, brother. helps alot.
@AMJEngineering Жыл бұрын
Thanks
@suheladesilva29336 ай бұрын
Thank you very much for this video.
@iniatiniat38222 жыл бұрын
Also take us through hvac ductwork design procedures
@AMJEngineering2 жыл бұрын
Will do
@jordanwclancy2 жыл бұрын
Thank you so much for this video. Could you please send me the ASHRAE table referenced at 10:14? Thank you!
@pshtiwanabdulmajeed67312 жыл бұрын
thnk you for excelant work simply how do i get all table pleas
@ochiengfaustineododa8409 Жыл бұрын
Hey @AMJ,,, can I get a listing of the Tables?? The ones not in ASHRAE Handbook
@soisaidtomydoctor32852 жыл бұрын
Keep up the good work 👏
@AMJEngineering2 жыл бұрын
Thanks for valuable feedback. Every share helps me keep going👍🌹
@reasmeingor19622 жыл бұрын
Hi sir, thanks for your video. I have a question, regarding the factor of LED light, how many factors for it?
@abdelnasiryosifabdelaziz3193 Жыл бұрын
Hello sir, this video was very helpful so I have a question, why the heat load through the floor was not calculated? the same question for the heat load through partitions between zoon 5 and the other adjacent zoons .
@FusssionMusik Жыл бұрын
I'm still trying to figure out how is 225/1000 x 5 = 2 at 16:37 I'm definitely not getting that answer. Is this an error? Also where did the 3.4 btu/hr/watt come from at 18:08?
@joabjim2 жыл бұрын
I have the 1997 ASHRAE Fundamentals Handbook, for Laredo Area, Table 1A is on page 26.18, and Table 1B is on page 26.19. Is there an error?. Thanks
@agungsantosa6020 Жыл бұрын
How can I get CLTD value for 75mm sandwich Panel material -2 Deg Latitudes. I can't find it in the existing tables.
@RabiatulAShuib2 ай бұрын
is it logic to get CLTD corrected = CLTD - 13.5 (because i have minus here later on in my calculation the Q is negative) is it correct or is this wrong?
@hassanqadeer7252 жыл бұрын
correction 11.48> Degree centigrade multiply by 1.8 and add 32 to get Fahrenheit
@AMJEngineering2 жыл бұрын
Yes you are right and thanks for your comment. I mentioned that I made this mistake in previous comments
@abbadubenzwin5157 Жыл бұрын
The computed automatic cooling system complex for big or large buildings by placing temperature sensors everywhere.. This is what calls for the possibility of studying air engineering circuits
@aldrenbungay6322 жыл бұрын
just want to clarify where did you get the 0.2 U-value for the wall..Thanks
@AMJEngineering2 жыл бұрын
This should be given for any type of wall.
@joao_cavalcanti Жыл бұрын
I am in doubt too. Type C3 >> R = 0,125 m2 k / W. It was suggested 0,88 m2 k / W (0,2 Btu / h ft2 °F. Maybe C13 (150mm High Density Concrete R=0,88 m2 K / W) could fix the numbers.
@rithysorm86927 ай бұрын
How to convert it@@joao_cavalcanti
@kylemanson3011 Жыл бұрын
what would you do if your wall doesnt match one of the given wall types?
@jorgeisaacvarelagamboa26337 ай бұрын
What do I do if my wall code number in table 11 is not in the table 33A?
@naumanfarooq67372 жыл бұрын
Kindly Can you provide all tables for 36 degree
@JohnFekoloid Жыл бұрын
8:42 Please where did you get this table from? Cannot find it in ASHRAE 1997 handbook
@gwv86476 ай бұрын
Did you find it?
@JohnFekoloid6 ай бұрын
@@gwv8647 No. didn't find it
@husammalquzahy2 жыл бұрын
Thanks for the video... It's was great for me.. Could you please send me the tables?
@luisaguilar124 Жыл бұрын
How can I calculate correctly U factor? Its just that Ashrae has a lot of tables for U values and I'm confused
@AMJEngineering Жыл бұрын
Depends on wall and roof types. Choose the nearest ashrea composition
@faviscore2200 Жыл бұрын
How can I get the ASHRAE value for UK
@MohitGoklani8 ай бұрын
At timestep 18:54 ; from where this space load comes?
@kartiniganesha6741 Жыл бұрын
Hello, your videos are very helpful. I have a question, instead of using the temperature of radiation from the sun, is it possible to apply the temperature from the fire if there is fire ?
@mohammadahasan94448 ай бұрын
Where you get u value from?
@backbones46514 ай бұрын
ashrae book
@yeunghubert2 жыл бұрын
Hi sir. May I know that how to get the Q(total) value at 18:29 table?
@mohammadahasan94448 ай бұрын
How to convert : w/m^2k to btu/hr-ft^2 -°f?
@JoseMelierSingson Жыл бұрын
Good day po, can i have a copy of solar cooling load for 8deg north latitude..ty
@rupomroy98 Жыл бұрын
can you provide me the ashrae 1997 fundamental book?
@arun48462 жыл бұрын
👍
@SiberianFenek2 жыл бұрын
Hi, thanks for the video. I have a question, for the roof, if we look at the R value, the higher it gets, the associated number in table 30 goes up wish means higher Cltd values. Whats bugs me, is the fact that with more insulation, we have more cooling load to deal with, but it seems counter intuitive. I would expect better insulation to mean less cooling. Am i missing something ?
@AMJEngineering2 жыл бұрын
please let me know the video timing you are referring to.
@SiberianFenek2 жыл бұрын
@@AMJEngineering i was refering to 8:09 with Roof no. In table 30 and R values in table 31. Additionaly, what does mass location mean ? And are the R values in table 31 for the complete roof composition, because even 5.3 seems low for a northern country. If i have an R = 6.5 whats do i pick in table 31 ?