Thank you for the most complete, most clearly presented, most thorough, most succinct, most helpful video on Manual J calculations on You Tube. I have watched so many presentations by so many so-called "experts" (including ACCA board members and authors associated with ACCA). Not a single one of those videos completely covers the process. All of them leave out some of the essential, necessary steps. None of them clearly provides enough specifics to actually do the Manual J analysis required by most jurisdictions for a new system install. Many of the so-called "experts" and "trainers" ramble on about irrelevant or personal information for the better part of 1 or 2 hours Typically, the presenters provide just enough information to get your interest and attention so that you will buy their book, pay for their services, or purchase parts or tools from their sponsors. Thanks again!
@charlton57872 жыл бұрын
I loved using those load calc tables, we were also an Airtime 500 contractor. Those calculations are the job so much easier when doing loads.
@demondude1000 Жыл бұрын
Easy video, I am jsut starting in the HVACR field so this is good info
@stlwrkr688 жыл бұрын
Great explanation!! Thanks for breaking this down into such an easy to understand way.
@eagletek110 жыл бұрын
Thanks for sharing.This will greatly bless our up coming business fulltime.
@Askexpertexpress10 жыл бұрын
your welcome
@tedjohnson64 Жыл бұрын
Excellent tutorial, thanks for sharing this!
@lucdumouchel3864 Жыл бұрын
Have 2 questions. How do you calculate gains from ductwork. And second: when it says number of people: I have a hall to calculate with about 60 people and 1 bathroom. Do I calculate only 1 bathroom or calculate 60 people?
@edithnogueira78995 жыл бұрын
I suggested to pay a company to get the AC load calculations rather to install based to 1 ton every 400 sf. I have installed a 3.5 ton AC to a 1570 sf house and the size was wrong. All the AC contractor agreed the size was between 3 and 3.5 ton, but all of them were wrong. The AC turned on and off quick without completing the cycle, and not removing the humidity and not cooling, and therefore creating mold. A professional calculations done by engineering company specializing on this, shows that the correct size was 2 ton., could go up to 10% high in size. The AC was replaced, and the problem resolved.
@scubastevoo84044 жыл бұрын
who taught you that? the only thing close would be 400 CFM per 1 TON. not sq. ft.
@Alhabshan_m6 жыл бұрын
Hello, thank you for your explaining. Actually, I did understand how we get the total BTU/h heat gain. Can you please show me how we calculate it?
@6barry662 жыл бұрын
Nice video where can I go to get a worksheet like the one you have.
@xalfonzx2648Ай бұрын
Anyone know how I can take classes online to learn calculation loads very accurately? Please and thank you
@dennmillsch4 жыл бұрын
Oops, at 02:00 you calculate 33 sq ft, however you entered 8 when it should have been 18, meaning it should been 43 square feet.
@dennmillsch4 жыл бұрын
I'd love to use this accu-size sheet but it only allows a few specific construction parameters. Doesn't work for R40 walls, or R-60 ceiling or triple glazed windows with U factor 0f 0.15. It could be useful if it had adaptable formulas rather than specific multipliers for specific construction only.
@Askexpertexpress4 жыл бұрын
If you have other than a standard home a quick load calculation is not for you. I recommend you use the wright soft manual J program to correctly determine the exact BTU load requirements.
@humbertodiaz31377 жыл бұрын
Hello, i like your video. thanks for taking the time publish it. i have one question? you said that this worksheet is only for the part of US where you live in, but what does it have to be changed in order to use it in other parts or in other countries?
@peerod6732 жыл бұрын
I love the explanation but I would love to know where they are getting the multiplier factor so I can convert to my region.
@Seabass12068 ай бұрын
you need to find an Resistance value table for your building materials and also find your areas outdoor design temp
@pabloantonio95072 жыл бұрын
Dope thanks for sharing
@jonathanavila96999 ай бұрын
Can I pay you to do a load calculation for me? Also how do you determine the region?
@heroknaderi4 жыл бұрын
Very helpful thanks 🙏
@Askexpertexpress4 жыл бұрын
Glad it was helpful!
@KenTraining2 жыл бұрын
Can you help me I am wanting to find CFM’s for rooms once I know the Btu/h heating and cooling loads. I have the Manual J8AE spread sheet and the CFM outputs seem high to me and I wanted to see other calculations. I tried the Sensible Heat Formula of CFM = Sensible Btuh / 1.1 * Delta T But when I input those numbers I get higher CFM needed in areas that have lower Btuh heat loss/gain. Here is my example Home is in Laguna Beach California The area labeled 1st Flr Master Bedroom has a heat loss of 9138 Btuh and a Heat Gain of 4807 Btuh Manual J8AE want to provide 299 cfm for heating and less air (244 cfm) for cooling If I do the sensible heat formula CFM = Sensible Btuh / 1.1 x ∆ T , I am using 29 ∆ T for heating and 10 ∆ T for cooling I get 286 cfm for heating and more air (437 cfm) for cooling. This does not make sense to me with needing more cfm with less of a Btuh load. Can you show me where I am thrown off?
@jayprojects51764 жыл бұрын
Awesome Video. I'm very interested in using this form. Where did this form come from?
@IA-ge1et7 жыл бұрын
Many thanks for sharing that with us. I can't help but wonder, how exactly you developed this sheet. I mean how you come up with multiplied numbers?
@Askexpertexpress7 жыл бұрын
+Al-Salama Ibraheem this is used by taking standard block load multipliers from government Publications
@Yo_Jon2 жыл бұрын
Thank you for this bro
@crownjewels1019 жыл бұрын
Great video. If the average degree day for heating changes from 0 in your example to 25 then would the multipliers change also?
@Askexpertexpress9 жыл бұрын
crownjewels101 yes they are different the multipliers are found in the manual j guide every area has a different average temp that is listed in the guide as well
@Andresseus7 ай бұрын
That's a cool pen.
@williamprothro20306 жыл бұрын
Where can I find the load sheets like you filled out
@amokoikaw12 жыл бұрын
HOW DID YOU GET 70,000 BTU and decided to get a 2 ton unit furnace? Thanks . . .
@peterkalinin37756 жыл бұрын
The formula is: 400 sf pet ton - for commercial and 500 sf per ton - for residential installations (8 ft ceiling).
@joshuacassino72974 жыл бұрын
Hello. I currently have a 40amp sub panel and need to accommodate an extra 60amps in it. In the 40amp sub panel there is a 15 amp and a 30amp. What size breaker do I need in the main?
@Alien-MAC6 жыл бұрын
if the home owner has a bunch of electronics, fridges, and other heat producing items, could u add a little on the top?
@islamfathi21847 жыл бұрын
If I have gymnasium and I want to calculate cooling capacity ,the area is 700m^2
@adambernard31964 жыл бұрын
For exterior heat loss, does it matter if there are rooms? Would you have a different total or heat loss per room?
@juliejanczak71510 ай бұрын
Where do u get the form
@robertpalmatier26992 ай бұрын
Where are you at 95 degree summer and zero degree winter?
@ashliemiller5287 жыл бұрын
How did he get the 44431 from
@notanaccidentorg2 жыл бұрын
Hello, are you still required to complete this for the exam in order to be certified? Thanks
@mohibnasir6 жыл бұрын
Can you please upload the link for the sheet you are using for writing all the values ?
@bklynwam7 жыл бұрын
What do you suggest if you have a bilevel or tri level house (that has a garage and basement)? Thanks.
@spojj0646 жыл бұрын
Does anyone have a form, like the one in the video, for me to fill out but for Florida. My county building department needs energy calculations for our house, and I will be submitting it as owner builder, so we don’t need a contractor.
@SkipsTransAm200210 жыл бұрын
Is there any way I can get a sheet like yours for alabama. It look easier? Thanks
@byrantilford9234 жыл бұрын
Where can I find that paper
@grindtime76sanchez209 ай бұрын
What’s an app that can do this? I’m a salesman not a mathematician 😅😅
@tonkie107 жыл бұрын
Regards friend. Great video. I'm designing a precision system for a data center, I have not experience working with data center precision cooling just with confort, so my questions are: do you have an example that you could share with me of load estimation for data centers? is the calculation procedure different from the confort loads? How do I know the needed power for a precision cooling system in a data center?. Thanks in advance for your help.
@Askexpertexpress7 жыл бұрын
+Jose julian we have designed hundreds of cooling systems for data center you have to use a commercial heat load calculation and find out what the manufacturing specs of the computers or other equipment located within the space is going to require as far as the BTU load for example Jose a computer puts off 3000 BTUs per hour x 1000 computers = 300k btu load. You also have to consider if it is an up Flow Design meaning that it's coming floor through the system your humidity will have to be controlled to prevent damaging the computers. You also have to look at static pressure within the room. Also take into effect static pressure on duct design
@sprinter91666 жыл бұрын
What would be your HTM for roll up metal shop doors? can't find in Manual J
@ManuelSanchez-ov2ed6 жыл бұрын
I'm in the Houston ,Tx area. Can you make one for this area, or do you know where I can get one just like the one you are showing?
@aidanheidel38378 жыл бұрын
good video, but how did you determine the final size of the furnace a/v unit? you did all the calculations but left out how you decided on a 2 ton unit. why? how? what was the purpose of all the calculations if you wer just gonna say, basically a 2 ton unit at the end. WTF
@One000Suns7 жыл бұрын
Late response but he determined it would be a 2 ton AC unit by adding up all the Heat Gain numbers (left side of paper). He calculated 24773 BTUs of heat gain (bottom of page @5:47) and that is about a 2 ton AC unit. The right side of the paper is for heat loss and that relates to heating.
@srercrcr7 жыл бұрын
Divide the 24773 BTU by 12000 = 2 ton.
@mayaroable5 жыл бұрын
2400 btu heat gain = 1200 btu per ton = 2ton of cooling. 61000 btu of heat loss÷.80 80% =a 80000 btu input furnace
@unibrowmonsterattack55278 жыл бұрын
Thank you for it!
@simsource50179 жыл бұрын
Hey can u send me the link to get this load calulation worksheets
@rokiyayo663310 жыл бұрын
Suscribed, good information
@sprinter91666 жыл бұрын
Giving a load calculation on a 40-60 home car garage with 16 ft ceilings, don't know what BTU's to add for a hot car but i assume it could be at least 10,000 BTU's per hr.
@rahulneela85545 жыл бұрын
Can u share PDF of the sheet
@MrFrostynugs4205 жыл бұрын
For retrofits, Use coolcalc.com and make sure your ductwork will support the cfm. 10 years doing calcs, all in Denver, only one complaint early on (wtf 8k sq ft house, loads get complicated with 6 and 1/2 systems) make a checklist with all required measurements and then xfer the info. It takes me one hour for measurements and another hour for completing the calc...+ drive time... All ways slightly oversize and design your sales programs to sell two stage equipment. Your fucking welcome kiddos! Best of luck!
@butlershvac46376 жыл бұрын
Can you create a sheet for Wilmington NC?
@theworshipdrummern86 жыл бұрын
Butlers HVAC check with your local offices. He didn’t “create” this. It’s an NEC type thing look online.
@gund891238 ай бұрын
Almost no HVAC contractor does these calculations anymore, they pulling numbers out of thin air now.
@billyrayboo73152 жыл бұрын
I guarantee you you have 10 different contractors do that same worksheet on that home and you have 10 different answers. 2 Ton 800 cfm on 1400 Sq plus ft house good luck with that. Also most new hi efficient units will throttle up and down with the load. So what do that tell you a variable speed unit will cover the range from 24000 btu to 3.5 tons. You still comply with that bullshit that units to big and you got enough cooling on the real hot days to whistle Dixie not even break sweat and still keep the energy consumption down. Most house have 12 to 15 supply grills. You put that many on a 2 ton there want be squat of air coming out the vents
@HiddenTruthExposed3 жыл бұрын
What are we cavemen
@Askexpertexpress10 жыл бұрын
@1984juant10 жыл бұрын
Hey i cant find that sheet i just get the spreadsheet of acca which i dont really like too much..
@1984juant10 жыл бұрын
Never mind i found it in your blog. But how can i get the one from my region??
@Askexpertexpress10 жыл бұрын
What region are you in. I will make one for your region and posted on my website
@juantapia807910 жыл бұрын
Im from south texas. I have house for this weekb i would like to try it. Thanks
@Askexpertexpress10 жыл бұрын
you can download the app "quick load" on the app store it works great and you can set the temps for your area
@SkipsTransAm200210 жыл бұрын
It will not let me Access the file you put on bottom? The block one?
@Askexpertexpress10 жыл бұрын
sorry here is the correct link www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/
@Askexpertexpress10 жыл бұрын
Expert Express plumbing heating and air conditioning click on the word heat for the pdf file
@Askexpertexpress10 жыл бұрын
Expert Express plumbing heating and air conditioning sorry heat loss
@SkipsTransAm200210 жыл бұрын
Thanks for your help! Is there any way I could get one for Alabama? I think it calls for a heat gain day of 93 and heat loss 23. Thanks again and great videos.
@sprinter91666 жыл бұрын
it probably won't hurt a bit to add 25% for people who keep there A/C on 67 degrees especially in extreme temps.
@MOPARMANIATEXAS6 жыл бұрын
EXCEPT that over sized will cause Mold.
@alanhumphrey4198 Жыл бұрын
What about in Texas??😊😊
@jeffreywilliams39446 жыл бұрын
Thank You
@eagletek110 жыл бұрын
can you share the sight to download form?
@Askexpertexpress10 жыл бұрын
www.acca.org/standards/acca-speed-sheets/ this is a link for the acca spread sheet I will be posting a copy of the block load sheet I use on our web site soon under the blog section
@Askexpertexpress10 жыл бұрын
here is the link to the work sheet I use www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/?preview=true&preview_id=1437&preview_nonce=dad3624c86
@Askexpertexpress10 жыл бұрын
here is the correct link www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/
@chrisej75868 жыл бұрын
Expert Express plumbing heating and air conditioning b
@SombraLocs5 жыл бұрын
@@Askexpertexpress Did you guys take it down?
@bobh14148 жыл бұрын
Where exactly did you get that form?
@srercrcr7 жыл бұрын
The form is in Google Images
@Askexpertexpress10 жыл бұрын
here is the link for the work sheet i use www.askexpertexpress.com/manual-j-heat-loss-heat-gain-block-calculation-work-sheet/?preview=true&preview_id=1437&preview_nonce=dad3624c86
@Barnekkid8 жыл бұрын
+Expert Express plumbing heating and air conditioning When I try to look at this I get a message saying I don't have permission to look at drafts. Is there another source?
@Askexpertexpress8 жыл бұрын
we are fixing the problem and will have it back up soon
@MR-nl8xr6 жыл бұрын
Expert Express plumbing heating and air conditioning. Problem still there.
@أحمدمصطفي-ذ9ج3 жыл бұрын
Good
@cyrusIIIII7 жыл бұрын
At the end why did you say you need a 2 Ton system? how did you calculate that for 61000 BTU? Shouldn't it be 5 Tons?
@One000Suns7 жыл бұрын
The number 61000 was for "heat loss" so it applies to heater sizing. The left side of his form was for calculating "heat gain." This is for cooling and the number he calculated was around 24000 btu (bottom of left side form).
@cyrusIIIII7 жыл бұрын
Thank you
@mariobenoit74867 жыл бұрын
So you divide number by 12 to get the tonage?
@srercrcr7 жыл бұрын
divide by 12000. One ton = 12000 BTU
@hvacguy115 жыл бұрын
2 ton seems small for a 1404 square foot home I know thats the math but on a 95 degree day that’s no going to work