Copper Testing with the OneExpert ONX-580, Session 2 (TDR, RFL)

  Рет қаралды 12,080

VIAVI Product Training Videos

VIAVI Product Training Videos

Күн бұрын

Пікірлер: 9
@cdurch1
@cdurch1 3 жыл бұрын
Can't believe there's not like, thousands of comments by now! This is an amazing explanation, probably one of jdsu/viavi's best kept secrets. Second time watching, it's soaking in... can't wait to watch it again. Want to master this RFL understanding, and it's application in the field. YES, I want to read the white paper, how do I get a copy?
@cturn9494
@cturn9494 2 жыл бұрын
you are awesome , me here at *** for 22 yrs, ST, (29 total), forced FT training, now i need training for copper cable repair, which i am now attending, but was against, but i have absolutely loved this video. i now want to learn more about it now! thanks, you are very personable and easy to listen to. i was actually talking back to you and nodding my head! irht!!
@ViaviSolutions
@ViaviSolutions 2 жыл бұрын
Thank you for the nice comment. We are glad this video was so helpful. Best of luck with your upcoming trainings.
@tunasand44
@tunasand44 3 жыл бұрын
RFL WAS a major time saver here in australia on the NBN project.
@motownharmony1
@motownharmony1 2 жыл бұрын
Can it be used to find HR both legs?
@just1nmke
@just1nmke 2 жыл бұрын
Had a hard short on tip and cross on ring side today that I couldn’t locate. That’s why I’m watching this video again
@sukhdeepsingh5028
@sukhdeepsingh5028 3 жыл бұрын
Hi jeff, we got two wires and one red jdsu clipper on faulty one and black clipper on good pair. But green for earth and how we can putt green on cable because we got only two pair cable. We do rfl to find how many meters from our side where we sit on pit or pillar. It’s confusing to connect green clipper on wire. It should be on earth.
@ViaviSolutions
@ViaviSolutions 3 жыл бұрын
Hello Sukhdeep Singh - Since we are creating an electrical circuit to measure an unknown electrical resistance by balancing two legs of a bridge circuit, one leg of which includes the unknown component, the lead connection needs to follow the diagram on the screen for single or separate pair. Either way, the green and red test leads will always be connected to the faulted side of the pair under test. As always, the gauge and temperature must be set also. If you have further questions, please email TAC at viavisolutions dot com.
@sukhdeepsingh5028
@sukhdeepsingh5028 3 жыл бұрын
These days mostly common problem is HIGH RESISTANCE. Like drop out. So could you please make more video on RFL test. For in my JDSU i have three leads. One is Red, Second is Black which we normally plug on every time for any result like. On cable. Third is Green colour that one we use for earth. Please describe us more information that would be appreciated from our company. 🙏🏻
Copper Testing with the OneExpert ONX-580, Session 3 (Wideband, TIMS, Spectral Noise)
1:42:11
Copper Testing with the OneExpert ONX-580, Session 1 (Multimeter, Opens, Balance,Load Coil)
1:50:06
УДИВИЛ ВСЕХ СВОИМ УХОДОМ!😳 #shorts
00:49
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 25 МЛН
Why no RONALDO?! 🤔⚽️
00:28
Celine Dept
Рет қаралды 118 МЛН
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 55 МЛН
How to Test Copper & xDSL Services with VIAVI One Expert DSL
2:00:35
VIAVI Solutions
Рет қаралды 37 М.
ONX 580 TDR Fundamentals
10:11
VanTek Consulting, LLC
Рет қаралды 1,6 М.
Identifying Series Faults Using ONX-580 (or other test meter)
9:10
VanTek Consulting, LLC
Рет қаралды 1,3 М.
Time Domain Reflectometry (TDR): Technology Review and Applications
1:06:16
Protec Equipment Resources
Рет қаралды 4,6 М.
VIAVI ONX DSL TDR (PET) Introduction - TMG Test Equipment
11:16
TMGTestEquipment
Рет қаралды 7 М.
What's inside the Raspberry Pi 500?
18:34
Level 2 Jeff
Рет қаралды 88 М.
JDSU HST 3000 - Resistance Testing
8:12
Microlease
Рет қаралды 23 М.
VIAVI OneExpert CATV: OneCheck Application
18:09
VIAVI Product Training Videos
Рет қаралды 9 М.
УДИВИЛ ВСЕХ СВОИМ УХОДОМ!😳 #shorts
00:49