Corrosion Inspection on Noisy Steel

  Рет қаралды 3,304

Holloway NDT & Engineering Inc.

Holloway NDT & Engineering Inc.

Күн бұрын

Пікірлер: 20
@monkey16384
@monkey16384 9 ай бұрын
The Ghost shirt you wore really helped me absorb the subject material Paul!! Folks in the trades have GREAT taste in music. Seriously, thank for the clear comparison of transducer size vs. probability of detection. As a soon to be UT2, this is a valuable lesson!
@hollowayndtengineeringinc.5201
@hollowayndtengineeringinc.5201 9 ай бұрын
I wanted to lower the table and show Papa Emeritus' full headshot, but the lights on my table move with it. Oh well, if you know Ghost, you know what he looks like. Awesome band live too!
@ndthero
@ndthero 9 ай бұрын
Fine job sir. Breaking down the sensitivity aspect between these transducers as it relates to corrosion and similar style indications is well done.
@rubiselcuba
@rubiselcuba 9 ай бұрын
Great video, Paul, as usual.
@Cluni-80s
@Cluni-80s 9 ай бұрын
I remember we faced a lot of noise while mapping the corrosion on tanks using Silverwing's Scorpion 2. If I am not mistaken, the Excel macro report generator they provided had a high/low filter that kept everything tidy. It was ages ago, so I am a bit fuzzy on the details, it might not be related to the video. Paul, you are the gift that keeps giving, as always, thank you for the valuable insights.
@simon-pierrelussier2775
@simon-pierrelussier2775 9 ай бұрын
IDK what I did to get this video suggested by youtube's algo, but I like it!
@hollowayndtengineeringinc.5201
@hollowayndtengineeringinc.5201 9 ай бұрын
I'll take driveby traffic anyday!! :)
@fishindude6799
@fishindude6799 9 ай бұрын
Could you do a video on erw longitudial seams.
@uw0538
@uw0538 7 ай бұрын
thank you for this videos ,there is a way to inspect corrosion without the contact with the material ??
@hollowayndtengineeringinc.5201
@hollowayndtengineeringinc.5201 7 ай бұрын
You could use low frequency eddy current, but it's more of a screening tool.
@uw0538
@uw0538 7 ай бұрын
@@hollowayndtengineeringinc.5201 do you have some documentation or example of that.thanks
@TheKajunkat
@TheKajunkat 9 ай бұрын
I would assume that almost all of the plate defects should show up at approximately half the nominal thickness.
@hollowayndtengineeringinc.5201
@hollowayndtengineeringinc.5201 9 ай бұрын
Sometimes yes, sometimes no. If you see the macro image, they could be anywhere. For laminations, yes... they're usually "big sheet" reflectors about half way thru
@TheKajunkat
@TheKajunkat 9 ай бұрын
@@hollowayndtengineeringinc.5201 is there a way to tell the difference in laminations and hydrogen blisters or hac?
@UTEXScientific
@UTEXScientific 9 ай бұрын
Thank you Paul!
@dinho9492
@dinho9492 9 ай бұрын
Thanks🙏 From Borneo ( Sarawak )
@santiagocruz9060
@santiagocruz9060 9 ай бұрын
In this case we asume HIC defect?
@hollowayndtengineeringinc.5201
@hollowayndtengineeringinc.5201 9 ай бұрын
Definitely not. If HIC is suspected for the service of the equipment, then an appropriate inspection technique should be applied. In this case, it's just noisy hot rolled steel.
@forbido
@forbido 9 ай бұрын
Great video
@abolfazlnaemnezhad7692
@abolfazlnaemnezhad7692 16 күн бұрын
👌🏿👌🏿👌🏿
Spike vs Square Pulser
4:33
Holloway NDT & Engineering Inc.
Рет қаралды 5 М.
dB Drop for Sizing Crack Height
4:41
Holloway NDT & Engineering Inc.
Рет қаралды 10 М.
#behindthescenes @CrissaJackson
0:11
Happy Kelli
Рет қаралды 27 МЛН
Ful Video ☝🏻☝🏻☝🏻
1:01
Arkeolog
Рет қаралды 14 МЛН
Caleb Pressley Shows TSA How It’s Done
0:28
Barstool Sports
Рет қаралды 60 МЛН
Flaw Characterization & Angle
4:47
Holloway NDT & Engineering Inc.
Рет қаралды 7 М.
Pitting Corrosion - Forms of Corrosion
7:03
Captain Corrosion
Рет қаралды 16 М.
Advanced FMC/TFM Demonstration on Large Aluminum Block
3:06
The Phased Array Company
Рет қаралды 3,7 М.
PAUT Zero Degree Wedge Repeaters (+ Tape?)
5:55
Holloway NDT & Engineering Inc.
Рет қаралды 3,2 М.
WW2 Willys Jeep assembled in less than 4 minutes amazing!!
3:52
JDubbs Garage
Рет қаралды 6 МЛН
Showing Scammers Their Own CCTV Cameras On My Computer!
18:26
6dB Drop is Not Great for Flaw Length Sizing
4:52
Holloway NDT & Engineering Inc.
Рет қаралды 15 М.
Mode Conversion
4:52
Holloway NDT & Engineering Inc.
Рет қаралды 3,7 М.
Receive Filter
4:34
Holloway NDT & Engineering Inc.
Рет қаралды 2,3 М.
#behindthescenes @CrissaJackson
0:11
Happy Kelli
Рет қаралды 27 МЛН