Counterbalance Valves

  Рет қаралды 84,104

GPM Hydraulic Consulting Inc

GPM Hydraulic Consulting Inc

Күн бұрын

Пікірлер: 50
@blooperreel7465
@blooperreel7465 2 жыл бұрын
Fantastic video. None of the others I watched explained it like this one does.
@michaelcostello6991
@michaelcostello6991 5 жыл бұрын
Very informative video. Great to see the actual installed valve. Thanks
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
Thank you for your comment!
@smca7271
@smca7271 5 ай бұрын
Great explanation, I see the control valve has changed from tandem (1yr ago) to float.I have tandem but have bought a counterbalance valve to install (loader always drops before it goes up,not good). Will it work? and why....these seem to be a bit of a tricky beast.
@mattpalmer7466
@mattpalmer7466 2 жыл бұрын
Very informative and easy to follow along. Thanks
@JackWeeks
@JackWeeks 2 жыл бұрын
Thank you, Matt!
@johnevan7737
@johnevan7737 4 жыл бұрын
Thanks for the video,very informative.I have encountered many applications of these valve w/o external pilot line,mostly w/ big Hyd Press.Does these somehow affect the operation of the counterbalance valve?
@JackWeeks
@JackWeeks 4 жыл бұрын
Thanks for your comment, John! If your valve has no external pilot, it's probably not really a counterbalance valve. I would like to see the schematic to explain fully, but the likelihood is that either your valve is an anti-cavitation relief valve or a velocity fuse to keep the press from dropping. Sometimes the external pilot is there but is not easy to find (perhaps a small internal line drilled in a manifold), but in order for it to be a counterbalance valve, the external pilot must be there somewhere. Hope this helps!
@hirwachristian8335
@hirwachristian8335 2 жыл бұрын
hi i need your help me one of our electric forklift aisle master when driver lowering the cargo mast starts shaking help me to finguring out the root cause
@JackWeeks
@JackWeeks 2 жыл бұрын
Sounds to me like your counterbalance valve is improperly set. As the cylinder is going down, if it is safe to do so, adjust until you find the exact stall point. Then lower the pressure about 1/4 turn. Hope this helps!
@lastnameavailableok
@lastnameavailableok 2 ай бұрын
no problem, I can come there and fix. Flights; US$8000, Hotel US$2000, Fix problem US$1500.
@hirwachristian8335
@hirwachristian8335 2 ай бұрын
@@JackWeeks can i get your whatapp number please
@samerasaad7010
@samerasaad7010 5 жыл бұрын
What is the best counterbalance pilot ratio to be used in hydraulic winch application? I have installed one 1:3 then the motor got jerking while we lowered the load and try metering input flow by flow control valve being installed in input line.
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
In general, lower pilot ratios provide the best stability and motion control. This is why most of them are 3:1. Higher ratios are only used when greater efficiency by producing less heat is of greater concern than motion control. I don't think that your pilot ratio is the cause of the jerking. It is more likely that you either have bypassing somewhere or the valve is not properly adjusted. Hope this helps!
@samerasaad7010
@samerasaad7010 5 жыл бұрын
@@Gpmhydraulic there were no proplems until operator try to reduce the throttle valve to speed lowering load down.
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
@@samerasaad7010 Then apparently the counterbalance valve is handling the load. Your issue appears to be one of adjustment.
@kareemabdelnaser4684
@kareemabdelnaser4684 Жыл бұрын
very good video .thanks
@ttshechkah
@ttshechkah 4 жыл бұрын
Hello. If I have maximum load pressure from the rod side 300 bar it means that my counterbalance valve spring set shall be 390 bar?
@Gpmhydraulic
@Gpmhydraulic 4 жыл бұрын
Thank you for your question! Yes, that is probably pretty close, but you will likely have to tweak it a bit one way or the other as said in the video.
@ttshechkah
@ttshechkah 4 жыл бұрын
@@Gpmhydraulic thank you for your answer. another question is: its hard to me find non vented counterbalance valve for spring set 390 bar. I use proportional valve with open throttled center, so backpressure is not forsee. is it necessary to use vented valve if spring set more than 350 bar? ps. piston ride side counterbalance spring set has 105 bar, so there I use 3 ports non vented valve.
@Gpmhydraulic
@Gpmhydraulic 4 жыл бұрын
@@ttshechkah only use a non-vented valve in applications that have no back-pressure in port 2 (inlet). Never use a non-vented valve in regeneration circuits, master-slave circuits and servo/proportional valve circuits.
@troubleshooter3052
@troubleshooter3052 4 жыл бұрын
@@Gpmhydraulic why does have to be a vented counterbalance valve with proportional valves? Can't a non vented counterbalance valve be used even if the proportional valve is the float center type? Thank you and greetings.
@Gpmhydraulic
@Gpmhydraulic 4 жыл бұрын
@@troubleshooter3052 It doesn't HAVE to be vented, but it usually is. This is to keep the counterbalance valve from throttling the actuator, limiting control by the valve. If your proportional valve doesn't control speed, then I suppose you don't need a vented counterbalace.
@angelovalentin4050
@angelovalentin4050 4 жыл бұрын
But other counterbalance valve is different way to adjust..they have ati clockwise to increase other is clockwise to increase
@JackWeeks
@JackWeeks 4 жыл бұрын
That is correct, Angelo - most of them do adjust clockwise to decrease, but some adjust clockwise to increase. The way to tell, when you are making the adjustment, if the adjuster screw moves in and out with the adjustment, it adjusts clockwise to increase. If, like most counterbalance valves however, the adjustment simply turns without going in or out, it adjusts clockwise to decrease pressure. Hope this helps!
@angelovalentin4050
@angelovalentin4050 4 жыл бұрын
@@JackWeeks when I does adjust CVV my move was check the rotation of adjustment...by the way im always watch your video
@SikanlalKhamari
@SikanlalKhamari 4 жыл бұрын
What is 1:3 ratio please explain
@JackWeeks
@JackWeeks 4 жыл бұрын
Silkanlal, sorry I missed your question - I see it was asked a whole month ago! I must have missed the notification email I usually get. The ratio is between the two surface areas of the internal and external pilots. If there is a 1:3 ratio, that means that it takes 3 times the pressure to open the valve from the internal pilot than it does the external (the external pilot is always the larger surface area and therefore requires less pressure to open the valve). Hope this helps!
@SikanlalKhamari
@SikanlalKhamari 4 жыл бұрын
@@JackWeeks thanks
@Eagle2pro
@Eagle2pro 5 жыл бұрын
What if there is no Load ?
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
If there is no load, pressure builds in the pilot line to whatever it takes to open the counterbalance valve and the cylinder extends.
@Eagle2pro
@Eagle2pro 5 жыл бұрын
What if no pilot
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
@@Eagle2pro Then the cylinder will never move unless the pressure is turned down very low. If there is no pilot line, it probably isn't a counterbalance valve, it's probably a relief valve to absorb shock.
@Eagle2pro
@Eagle2pro 5 жыл бұрын
Ever had a counter balance valve stuck in the closed position however can freely go through the check valve only.
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
@@Eagle2pro It can happen, yes. But it's much more likely to fail open than closed. It usually takes relatively large contaminants on the cylinder side of the valve to stick one closed.
@saleemshaikh1486
@saleemshaikh1486 3 жыл бұрын
dnt mentioned writing
@wristygaming5352
@wristygaming5352 3 жыл бұрын
really super helpful
@JackWeeks
@JackWeeks 3 жыл бұрын
Thank you, Wristy!
@adriansamuel1474
@adriansamuel1474 4 жыл бұрын
To much light for the projector
@JackWeeks
@JackWeeks 4 жыл бұрын
Agreed, Adrian. Unfortunately that was beyond our control when this was recorded. It is our hope that the message was informative enough to overcome the lighting.
@adriansamuel1474
@adriansamuel1474 4 жыл бұрын
@@JackWeeks yes is was really informative you bring it really good
@adriansamuel1474
@adriansamuel1474 4 жыл бұрын
Do you all give online training from your school
@JackWeeks
@JackWeeks 4 жыл бұрын
@@adriansamuel1474 We used to. Unfortunately, as of September 30th, GPM Hydraulic Consulting had to shut down its operation as a result of the effects of Covid-19. Now, having said that, I am currently building my own online fluid power training solution incorporating not only an online course such as the one this video came from as well as shorter courses for those who may not want the full course. In addition to the self-paced learning, I will also be doing webinars and live streaming virtual classroom training. The courses can be purchased separately or get a monthly subscription with full access to all materials and classes. I'm hoping to launch by the first of the year.
@adriansamuel1474
@adriansamuel1474 4 жыл бұрын
@@JackWeeks when you start count me in don’t forget to message me
@jiantkiller123
@jiantkiller123 5 жыл бұрын
Why two pilots....even one of the two pilots can fulfill the function.
@Gpmhydraulic
@Gpmhydraulic 5 жыл бұрын
Thank you for your question, Gaurish. There must be an external pilot in order to avoid excessive resistance and to maintain the flow through the valve at the rate supplied by the pump without respect to gravity. With only one pilot, gravity will influence the speed of descent.
@karasyov
@karasyov Жыл бұрын
100 psi is not a completely correct value.
Counterbalance Valves (Full Lecture)
24:31
Jim Pytel
Рет қаралды 116 М.
What is Counter Balance valve |#Counterbalance valve working|Hydraulic Lock| Ramesh S|RMETC
6:53
Chief Engineers TeaTimeTalk | Marine Engineering
Рет қаралды 2,8 М.
Ozoda - Alamlar (Official Video 2023)
6:22
Ozoda Official
Рет қаралды 10 МЛН
진짜✅ 아님 가짜❌???
0:21
승비니 Seungbini
Рет қаралды 10 МЛН
How to Set a Counterbalance Valve - Sun Hydraulics
8:58
Sun Hydraulics
Рет қаралды 34 М.
Load Holding and Motion Control Valves (Live From July 22, 2021)
2:08:50
LunchBox Sessions
Рет қаралды 286 М.
Cylinder Drift
5:16
LunchBox Sessions
Рет қаралды 240 М.
The Difference Between Pressure and Flow
7:34
Jack Weeks
Рет қаралды 536 М.
Hydraulic System Inspection & Troubleshooting Session 2
24:10
How a Pilot to Open Check Valve Works
4:27
KletteTech
Рет қаралды 2,4 М.
Vertical Cylinder Motion with a Counterbalance Valve
3:46
LunchBox Sessions
Рет қаралды 331 М.
Counterbalance Valve Circuit Animation | Fluid Power System
4:24
Engineering Xplained
Рет қаралды 690
Proportional Directional Valves: Fun With Electro-Hydraulics
1:33:58
LunchBox Sessions
Рет қаралды 326 М.
Ozoda - Alamlar (Official Video 2023)
6:22
Ozoda Official
Рет қаралды 10 МЛН